Resumo do conteúdo contido na página número 1
PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
POR FAVOR LEA Y
GUARDE TODAS!
AOS7 131
I II 2h 4h 40% 60%
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
a Instructions for use (5 – 16) en a Instructions d‘utilisation (17 – 28) fr a Instrucciones para el uso (29 – 9) es
Resumo do conteúdo contido na página número 4
Resumo do conteúdo contido na página número 5
en Instructions for use
Resumo do conteúdo contido na página número 6
en PLEASE READ AND SAVE ALL THESE INSTRUCTIONS! Important safety instructions • Do not touch the water in the base during operation • The use of water additives, such as ethereal/essential • Prior to using the appliance, read through the in because of high frequency vibrations in the water. oils, fragrances, eucalyptus, water conditioners etc., structions for complete use and retain in a safe place • Do not run power cords under c
Resumo do conteúdo contido na página número 7
en 1 4 2 8 3 9
Resumo do conteúdo contido na página número 8
Foreword Description of the appliance Setting up e en n Congratulations on your choice of the Ultrasonic Finding the ideal location for your unit Mist outlet (rotating) AIR O SWISS 7131! • Do not place the humidifier directly next to a heating element or on a floor with floor heating. The moisture Did you know that dry room air: of the mist can damage the floor surface (6) (see Sa • Causes the membranes in your respiratory system
Resumo do conteúdo contido na página número 9
Filling the tank e en n 10 13 Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The red light comes on indicating tank is empty. • Make sure that no foreign objects are in the water tank. • Take off the water
Resumo do conteúdo contido na página número 10
Water quality maintenance Operation 131 Replacement of the demineralization e en n © An Ionic Silver Stick (16) keeps the water free of harmful cartridge bacteria. The anti microbial action of silver is used. The Always unplug the unit before removing the Ionic Silver Stick releases silver ions in the water over water tank. Do not touch the water in the base a long period (approx. one year). It‘s self regulating and during operatio
Resumo do conteúdo contido na página número 11
Option B: replace the whole cartridge e en n 1 22 23 • Remove the cover (Caution: the mist outlet is loose!). Remove the water tank from the base and unscrew the water tank cap (17). • The demineralization cartridge is attached to the inside of the tank cap. Unscrew the cartridge from the cap by turning it counter clockwise (18). Important: do NOT dispose of the water tank cap! • Throw the whole cartridge into the waste (21). •
Resumo do conteúdo contido na página número 12
ACID ACID Cleaning/Maintenance e en n 2 31 Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! • Switch off the appliance and unplug it from the socket before cleaning it (27). • Clean the water tank and the base regularly. Use water O/I only, no detergents (28). • Use decalcification agents to remove deposits from the membrane regularly (29 and 30). For best results use EZ
Resumo do conteúdo contido na página número 13
Storing the appliance for extended periods Technical data en Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, Electrical voltage 120 V / 60 Hz in a dry place away from high temperatures. Power consumption up to 45 W Legal notice Humidity output up to 2.5 gallons /24 h The humidifier is UL listed. 2 Suitable for rooms up to 540 sq ft / 50 m Subject to technica
Resumo do conteúdo contido na página número 14
General Humidifier Questions Q. Why do I need a humidifier when I can just open Ultrasonic Frequent Questions en my window? Q. Why isn’t there enough moisture in my room? A. The moisture level within the outside air is not high Q. Why does it say open/close on the demineralization A. How often do you run the unit? If the unit is only run at enough to humidify a room. cartridge cap? night, then during the day the moisture level will drop if A. Thos
Resumo do conteúdo contido na página número 15
is used. An indication of when the DMC needs to be en changed can be white dust or reduced amount of mist output. Q. Is it ok to use distilled water with the unit? A. Yes, it is fine to use distilled water with the unit. If distilled water is used, it will prolong the life of the DMC. Q. I just replaced the contents of the cartridge and now have granules everywhere. A. First, make sure there are no granules in the middle of the ca
Resumo do conteúdo contido na página número 16
en 1
Resumo do conteúdo contido na página número 17
AIR-O-SWISS is a brand name of PLASTON AG, Switzerland.