Resumo do conteúdo contido na página número 3
03 electrolux contents safety precautions electrolux 04 Safety precautions 6.7 How the air conditioner works.............................................................40 To prevent injury to the user or other people and property damage, the following - Automatic operation instructions must be followed. - Cool/Heat and Fan only operation Incorrect operation due to ignoring of instructions may cause harm or damage. - Dry operation The seriousness is classified by the following indications. - A
Resumo do conteúdo contido na página número 4
05 electrolux safety precautions safety precautions electrolux 06 conditioner. It contains may cause an electric shock. contaminants and could make you 20.Ventilate the room well when used sick. together with a stove, etc. An 10.Do not use the power cord close to oxygen shortage may occur. heating appliances. It may cause 21.When the unit is to be cleaned, fire and electric shock. switch off, and turn off the circuit 11.Do not damage or use an breaker. Do not clean unit when unspecifie
Resumo do conteúdo contido na página número 5
07 electrolux safety precautions choosing the installation site electrolux 08 Choosing the installation site there is concern of damage due to Precautions for Installation falling of unit. Installation at the following sites may cause problems. If you must inevitably 28.Always insert the filters securely. install the unit at one of these sites, please consult your local distributor Clean filter once every two weeks. beforehand: Operation without filters may 1. Site with machine oil. caus
Resumo do conteúdo contido na página número 6
09 electrolux outdoor unit parts list electrolux 10 Parts list More Outdoor Unit More More NUMBERING PART NAME QTY. than 60cm than 30cm than 30cm 1. The outdoor unit must be installed 1 1 Installation plate at a convenient site that is not exposed to strong winds. The site 2 Clip anchor 8 should be dry and well ventilated. 3 8 Self-tapping screw A ST3.9x25 2. The site must support the weight 4 1 Seal of the outdoor unit and allow for vertical installation. 5 Drain Joint 1 3. There must n
Resumo do conteúdo contido na página número 7
272 11 electrolux parts list indoor unit installation electrolux 12 Indoor unit installation Installation plate description 1 More than 15cm 2 3 above 150mm from Indoor unit outline Installation plate the ceiling Indoor unit More than 12cm above 120mm above 120mm from the wall from the wall 45 90 Refrigerant pipe Refrigerant pipe hole (left) Ø 65 hole (right) Ø 65 6 A More than 12cm Models < 12000 Btu’s (A: 710, B: 250) Air filter Model 12000 Btu’s (A: 790, B: 265) 6 More than 60cm 7 In
Resumo do conteúdo contido na página número 8
13 electrolux indoor unit installation indoor unit installation electrolux 14 150mm del techo Connective pipe and drainage installation 998 380 380 119 Do not block Drainage Do not block water flow water flow 1. Run the drain hose sloping by a rise. by a rise. downward. Do not install the drain above 120mm above 120mm from the wall hose as illustrated below. from the wall 130 130 2. When connecting extension drain hose, insulate the connecting part Do not put the end Refrigerant pipe of dra
Resumo do conteúdo contido na página número 9
15 electrolux indoor unit installation outdoor unit installation electrolux 16 Outdoor unit installation 1. Install the outdoor unit on a rigid 3. Piping can easily be made by lifting base to prevent increasing noise the indoor unit with a cushioning level and vibration. material between the indoor unit 2. Determine the air outlet direction and the wall. Get it out after finish where the discharged air is not piping. blocked. In the case that the 4. Push the lower part of the indoor uni
Resumo do conteúdo contido na página número 10
17 electrolux outdoor unit installation refrigerant pipe connection electrolux 18 Refrigerant pipe connection A Flaring work Settlement of outdoor unit Air inlet Anchor the outdoor unit with Main cause for refrigerant leakage is a bolt and nut 10 or 8 tightly Air due to defect in the flaring work. and horizontally on a concrete inlet Carry out correct flaring work using Pipe or rigid mount. B the following procedure: 1. Cut the pipes and the cable. Air outlet A) Use the piping kit accessory o
Resumo do conteúdo contido na página número 11
19 electrolux refrigerant pipe connection electrical work electrolux 20 Electrical work Electric safety regulations for the initial Installation 4. Flaring work A) Firmly hold copper pipe in a die in 1. If there is serious safety problem 5. According to the attached Electrical Bar the dimension shown in the table about the power supply, the Connection Diagram located on the Copper below. pipe technicians should refuse to install panel of the outdoor unit to connect the air conditioner and e
Resumo do conteúdo contido na página número 12
21 electrolux electrical work electrical work electrolux 22 Connect the cable to the indoor unit 1. The inside and outside connecting Electrical box < 24000 Btu's < 24000 Btu's cable can be connected without cover COOL MODELS HEAT AND COOL MODELS removing the front grille. "Connector A" or "Connector B" "Connector A" or "Connector B" 2. Connecting cable between indoor unit Wire connector of indoor unit Wire connector of indoor unit and outdoor unit shall be approved polychloroprene sheathe
Resumo do conteúdo contido na página número 13
23 electrolux electrical work electrical work electrolux 24 Connect the cable to the outdoor unit < 24000 Btu's < 24000 Btu's 1. Remove the electrical control board COOL MODEL HEAT & COOL MODEL cover from the outdoor unit by "Connector A" or "Connector B" "Connector A" or "Connector B" Cover loosening the screw. Wire connector of outdoor unit Wire connector of outdoor unit Screw 2. Connect the cables to the terminals as 1 2(N) 3 4 1 2(N) 3 4 identified with their respective or 1 2(N) 1 2(N
Resumo do conteúdo contido na página número 14
25 electrolux electrical work electrical work electrolux 26 Caution Air purging with vacuum pump After the confirmation of the above conditions, prepare the wiring as follows: 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test 1. Never fail to have an individual power circuit specifically for the air run has been completed. Remove the service valve caps from both the gas conditioner. As for t
Resumo do conteúdo contido na página número 15
27 electrolux electrical work electrical safety electrolux 28 Electrical safety Perform the electric safe check after completing installation: When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Insulated resistance: The insulated resistance must be more than 2M . 2. Grounding work: After finishing grounding work, measure the grounding 1. Completely tighten the flare nuts, 8. Fully open the packed valve stems resistance by visual detection an
Resumo do conteúdo contido na página número 1
INSTRUCTIONS MANUAL
SPLIT TYPE ROOM AIR CONDITIONER
MODELS:
EAS(C,E)09C2ASK(W,S,M) / EAS(C,E)12C2ASK(W,S,M)
EAS(C,E)18C2ASK(W,S,M) / EAS(C,E)24C2ASK(W,S,M)
EAS(C,E)09P5ASK(W,S,M) / EAS(C,E)12P5ASK(W,S,M)
EAS(C,E)18P5ASK(W,S,M) / EAS(C,E)24P5ASK(W,S,M)
Please read this manual completely before operating your room air conditioner.
110823P
S(351-358)EM_ENGLISH
Resumo do conteúdo contido na página número 2
01 electrolux welcome contents electrolux 02 Contents Welcome to the world of simple handling and no worries. 01. Welcome.........................................................................................................01 Thank you for choosing Electrolux. This manual contains all of the information 02. Environmental advices....................................................................................01 required to guarantee your safety and the appropriate use of your air 03. Con
Resumo do conteúdo contido na página número 16
29 electrolux operation test preparing the device for operation electrolux 30 Operation test Preparing the device for operation Perform test operation after completing gas leak check at the flare nut 1. Contact a specialist to install the device. connections and electrical safety check. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 1. Connect the power, press the cannot be controlled by the remote 3. Before operating the
Resumo do conteúdo contido na página número 17
31 electrolux product description product description electrolux 32 Product description Display panel 1 Front panel frame (indoor unit) 2 Front panel 3 13 DEFROST*: Displayed when the Air filter air conditioner starts defrosting (inside front panel) automatically or when the warm air 4 Horizontal airflow grille control feature is activated in 5 Vertical airflow grille heating operation. 6 Temperature sensor *Nota: For Heating & Cooling model (inside front panel) only. 7 Panel Infra-red si
Resumo do conteúdo contido na página número 18
33 electrolux remote control remote control electrolux 34 Remote control Remote control operation When should the batteries be been received and transmitted in the replaced indoor unit. 1. Operation mode: Cool, Heat (Only for the models with cool/heat), DRY, FAN, 1. When there is not a “beep” 3. When selecting the function of and AUTO (Automatic). timer, the remote control sends anymore from the indoor unit (automatically) a signal to the indoor when using the control remote or 2.
Resumo do conteúdo contido na página número 19
35 electrolux remote control description remote control description electrolux 36 Remote control description 1 6 DIRECTION: Press this button to ON/OFF: Push this button to start change the swing angle of the operation, push the button again to louver. The swing angle of the stop operation. louver is 6o for each press. When MODE: Each time you push the 2 the louver swing at a certain button, a mode is selected in a angle which would affect the sequence that goes from AUTO, cooling and
Resumo do conteúdo contido na página número 20
37 electrolux remote control description lcd display indicators electrolux 38 LCD display indicators 1 11 CANCEL: Push this button to TRANSMISSION INDICATOR: This cancel the TIMER ON/OFF transmission indicator lights when 1 2 3 settings. remote controller transmits signals 12 TURBO*: Push this button on to the indoor unit. COOL mode, the air conditioner goes into powerful cooling 2 MODE: Displays the current operation. Push again to cancel operation mode. Including the TURBO fun