Resumo do conteúdo contido na página número 1
User Guide
Architectural Connectivity
®
Cable Cubby 200
Cable Access Enclosure
68-1557-01 Rev. A
10 12
Resumo do conteúdo contido na página número 2
Safety Instructions Safety Instructions • English Chinese Simplified (简体中文) 警告: 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated dangerous voltage 电压,有触电危险。 within the product’s enclosure that may present a risk of electric shock. 注意: 产品 上 的 这个标 志意在 提 示用户设备 随 附的用户手 册 中有 重要的操作和维护(维修)说明。 ATTENTION: This symbol, , when used on the product, is intended to alert the user of important operating and maintenan
Resumo do conteúdo contido na página número 3
Conventions Used in this Guide The following notifications are used: CAUTION: A caution indicates a situation that may result in minor injury. ATTENTION: Attention indicates a situation that may damage or destroy the product or associated equipment. NOTE: A note draws attention to important information. Specifications Availability: Product specifications are available on the Extron website, www.extron.com. Copyright © 2012 Extron Electronics. All rights reserved. Trademarks All trademarks men
Resumo do conteúdo contido na página número 4
Resumo do conteúdo contido na página número 5
Contents Introduction............................................................ 1 Reference Information ...................................... 10 Overview ............................................................ 1 Enclosure Part Numbers ................................... 10 Cable Cubby 200 Features ................................ 1 Included Accessories Part Numbers ................. 10 Routing Template Part Numbers ....................... 11 Top Plate Dimensions ........................
Resumo do conteúdo contido na página número 6
Introduction Overview The Extron Cable Cubby 200 is a furniture-mounted, architectural solution that provides inconspicuous cable access and connection points. When cables are not in use, they can be stored out of the way while remaining connected to the presentation system. Lift the lid to access the AAPs and connectors. Audio Cable, Network Cable 15-pin HD Cable Power Laptop Mounted through a table or lectern Extron Cable Cubby 200 Cable Access Enclosure Cable Cubby 200 Features AC Power O
Resumo do conteúdo contido na página número 7
Kit Contents Included Parts Image Part Quantity Cable Cubby 200 enclosure 1 Cable pass-through AAPs 2 Cable stand-offs 4 Mounting screws 4 (6-32 x 3/4 inch) Grommet and hole plug kit 1 Cable Cubby 200 • Kit Contents 2
Resumo do conteúdo contido na página número 8
Before Getting Started This section describes important information about the Cable Cubby 200 and planning considerations for installation. Topics in this section include: • About the Cable Cubby 200 • Planning • Tools and Equipment Required for Installation About the Cable Cubby 200 Figure 1. Cable Cubby 200 Enclosure with Populated AAPs The Cable Cubby 200 provides an unswitched AC power outlet appropriate to local distribution regions. Several different types of power receptacles are av
Resumo do conteúdo contido na página número 9
Planning Determine the best location for the enclosure. Before making any cuts: • Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. • Ensure that the edge on which the lid opens is oriented correctly. • Ensure that there is ample space under the table for cables. • Ensure that the correct template or dimensions are used. NOTE: The table to host the Cable Cubby 200 must have a thickness of at least 3/8 inch (9.5 mm) to ensure that
Resumo do conteúdo contido na página número 10
Installation This section provides information for an experienced installer to set up and install the Cable Cubby 200. Before starting, decide where to install the Cable Cubby, verify that all included parts are accounted for, and gather the necessary equipment for installation. CAUTION: Risk of injury to the eyes. Wear safety glasses when operating the router. Failure to comply can result in eye injury. Topics in this section include: • Installation Overview • Preparing the Table • Instal
Resumo do conteúdo contido na página número 11
CABLE CUBBY 200 USER CABLE CUBBY 200 ACCESS CABLE CUBBY 200 UC SE AB R LA E C C CE UB SS BY 200 Preparing the Table Extron recommends cutting the hole in the table with the Extron metal routing template (see “Routing Template Part Numbers” on page 11 for part numbers). NOTE: The hole can be also cut with a CNC wood router or a paper cut-out template (available on the Extron website, www.extron.com), but these methods are not recommended. ATTENTION: Potential damage to property. • Exercise car
Resumo do conteúdo contido na página número 12
CABLE CUBBY 2 200 00 C C CA A AB B BLE CU LE LE C CU UBBY 20 B BB 0 U U USE S SE ER R R A A AC C CCES C S Router CAUTION: Risk of injury to the eyes. Wear safety glasses when operating the router. Failure to comply can result in injury. d. Using a router with a 5/8 inch (16 mm) outside diameter guide bushing and a 1/2 inch (12 mm or 12.7 mm) diameter straight router bit, carefully cut the opening in the surface. e. Remove the C-clamps and the routing template assembly. Installing and Ca
Resumo do conteúdo contido na página número 13
3. Install Any Necessary Split Grommets and Hole Plugs a. Slip the appropriate split grommet over each cable with the flange of the grommet toward the connector that will be accessible inside the Cable Cubby. Snap the grommets into the channels. b. If necessary, snap the included hole plugs into unused holes. 4. Adjust the Cable Position The Cable Cubby 200 has four cable stand-offs that set the height of the cables inside the enclosure. a. Choose the row that best lifts the cable Ü
Resumo do conteúdo contido na página número 14
Mounting the Cable Cubby ATTENTION: Potential damage to property. The flanged edges of the top of the surface enclosure are sharp and soft, making them easy to nick or bend. Handle the enclosure with care to prevent personal injury and to avoid damaging the enclosure. 1. Test the Fit a. Remove the plastic strips on finished surfaces of the Cable Cubby. ATTENTION: Potential damage to property. Do no use isopropyl alcohol or other solvents to clean the Cable Cubby. Strong solvents will r
Resumo do conteúdo contido na página número 15
Reference Information This section provides part numbers for the Cable Cubby 200 and related products. Visit the Extron website, www.extron.com, for more details and part numbers. Topics in this section include: • Enclosure Part Numbers • Included Accessories Part Numbers • Routing Template Part Numbers • Top Plate Dimensions Enclosure Part Numbers Cable Cubby 200 Part Number Cable Cubby 200 - One US/domestic AC 60-716-0A Cable Cubby 200 - One Universal AC 60-716-0J Cable Cubby 200 - One
Resumo do conteúdo contido na página número 16
Cable Pass-through AAPs (see figure 2) Part Numbers Cable pass-through (right) 70-267-01 Cable pass-through (left) 70-270-01 Grommet and Plug Kit Part Numbers Grommet and hole plug kit 70-387-01 Routing Template Part Numbers The Cable Cubby 200 metal routing template (see figure 3) is the only preferred and recommended method for cutting the table. It is available on the Extron website, www.extron.com. Template Part Numbers Cable Cubby 200 Routing Template 70-384-01 CABLE CUBBY 200 CABLE CUBB
Resumo do conteúdo contido na página número 17
(1.90 cm) .350" User Access 3.155 0.0325" (8.01 0.083 cm) Top Plate Dimensions If you choose not to use the Extron metal routing template, the paper cut-out template will help you properly prepare the mounting surface (see figure 4). The cutout template is not to scale and is for reference only. For full size paper templates, visit the Extron website (www.extron.com) or call the Extron S3 Sales and Technical Support Hotline. Cut-Out Template for Cable Cubby 200 4.394" (11.16 cm) .350"
Resumo do conteúdo contido na página número 18
Extron Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within t