CONTACT INFORMATION Website: wolfappliance.com As you follow these instruc tions, you will notice WARNING and CAUTION symbols. This blocked information is impor tant for the safe and efficient installation of Wolf equip- ment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Anothe
Resumo do conteúdo contido na página número 5
WOLF E SERIES BUILT-IN OVENS INSTALLATION REQUIREMENTS SITE PREPARATION IMPORTANT NOTE: This installation must be IMPORTANT NOTE: A minimum 610 mm of completed by a qualified technician. usable cabinet depth is required, or the back panel of the cabinet may need to be removed IMPORTANT NOTE: Save these Installation for proper installation. A minimum 635 mm of Instructions for the local inspector’s use. usable cabinet depth is required for a flush Please read the entire Installation Instruc- inse
Resumo do conteúdo contido na página número 6
WOLF E SERIES BUILT-IN OVENS E SERIES BUILT-IN SINGLE OVENS MODELS ICBSO30-2F/S AND IMPORTANT NOTE: Unless you are using ICBSO30-2U/S cabinets deeper than 610 mm for a standard installation or 635 mm for a flush inset installa- IMPORTANT NOTE: A minimum 610 mm of tion, it is recommended that the electrical usable cabinet depth is required, or the back supply be placed in an adjacent cabinet. panel of the cabinet may need to be removed Choose the location shown in the installation for proper inst
Resumo do conteúdo contido na página número 7
INSTALLATION INSTRUCTIONS E SERIES BUILT-IN SINGLE OVENS STANDARD INSTALLATION COMBINATION INSTALLATIONS IMPORTANT NOTE: For standard installations, The Wolf E Series single oven may be installed a minimum 610 mm of usable cabinet depth is below a Wolf 762 mm induction, electric or gas required, or the back panel of the cabinet may cooktop. Unless you are using cabinets deeper need to be removed for proper installation. than 610 mm for a standard installation or 635 The electrical box must be fl
Resumo do conteúdo contido na página número 8
WOLF E SERIES BUILT-IN OVENS E SERIES BUILT-IN SINGLE OVENS STANDARD INSTALLATION Overall Oven Width 759 mm Minimum Cabinet Width 762 mm Overall Oven Height 708 mm Minimum Cabinet (Opening) Depth 610 mm Overall Oven Depth (behind frame) 603 mm Opening Width 724 mm Open Door Clearance 559 mm Opening Height 691 mm Recommended Cabinet Width 838 mm Minimum Base Support 113 kg STANDARD INSTALLATION – MODELS ICBSO30-2F/S AND ICBSO30-2U/S 838 mm RECOMMENDED CABINET WIDTH 762 mm min E 610 mm 724 mm OPEN
Resumo do conteúdo contido na página número 9
INSTALLATION INSTRUCTIONS E SERIES BUILT-IN SINGLE OVENS FLUSH INSET INSTALLATION Overall Oven Width 759 mm Minimum Cabinet Width 838 mm Overall Oven Height 708 mm Minimum Flush Inset Depth 635 mm Overall Oven Depth (behind frame) 603 mm Opening Width 724 mm IMPORTANT Open Door Clearance 559 mm Minimum Flush Inset Width 772 mm NOTE Minimum Base Support 113 kg Opening Height 691 mm For flush inset Minimum Flush Inset Height 724 mm installations, the inside edges of the rough opening must be finis
Resumo do conteúdo contido na página número 10
WOLF E SERIES BUILT-IN OVENS E SERIES BUILT-IN DOUBLE OVENS MODELS ICBDO30-2F/S AND IMPORTANT NOTE: Unless you are using ICBDO30-2U/S cabinets deeper than 610 mm for a standard installation or 635 mm for a flush inset installa- IMPORTANT NOTE: A minimum 610 mm of tion, it is recommended that the electrical usable cabinet depth is required, or the back supply be placed in an adjacent cabinet. panel of the cabinet may need to be removed Choose the location shown in the installation for proper inst
Resumo do conteúdo contido na página número 11
INSTALLATION INSTRUCTIONS E SERIES BUILT-IN DOUBLE OVENS STANDARD INSTALLATION FLUSH INSET INSTALLATION IMPORTANT NOTE: For standard installations, IMPORTANT NOTE: For flush inset installa- a minimum 610 mm of usable cabinet depth is tions, a minimum 635 mm of usable cabinet required, or the back panel of the cabinet may depth is required, or the back panel of the need to be removed for proper installation. cabinet may need to be removed for proper The electrical box must be flush with the back
Resumo do conteúdo contido na página número 12
WOLF E SERIES BUILT-IN OVENS E SERIES BUILT-IN DOUBLE OVENS STANDARD INSTALLATION Overall Oven Width 759 mm Minimum Cabinet Width 762 mm Overall Oven Height 1292 mm Minimum Cabinet (Opening) Depth 610 mm Overall Oven Depth (behind frame) 603 mm Opening Width 724 mm Open Door Clearance 559 mm Opening Height 1260 mm Recommended Cabinet Width 838 mm Minimum Base Support 181 kg STANDARD INSTALLATION – MODELS ICBDO30-2F/S AND ICBDO30-2U/S 838 mm RECOMMENDED CABINET WIDTH 762 mm min E 610 mm min 724
Resumo do conteúdo contido na página número 13
INSTALLATION INSTRUCTIONS E SERIES BUILT-IN DOUBLE OVENS FLUSH INSET INSTALLATION Overall Oven Width 759 mm Minimum Cabinet Width 838 mm Overall Oven Height 1292 mm Minimum Flush Inset Depth 635 mm Overall Oven Depth (behind frame) 603 mm Opening Width 724 mm IMPORTANT Open Door Clearance 559 mm Minimum Flush Inset Width 772 mm NOTE Minimum Base Support 181 kg Opening Height 1260 mm For flush inset Minimum Flush Inset Height 1294 mm installations, the inside edges of the rough opening FLUSH INSE
Resumo do conteúdo contido na página número 14
WOLF E SERIES BUILT-IN OVENS STANDARD INSTALLATION OPTIONS E SERIES BUILT-IN SINGLE OVEN Keep in mind that the size of the custom panel for the warming drawer with integrated The Wolf E Series single oven may be installed drawer front will vary according to the in combination with a Wolf convection or non- specific installation. Refer to the installation convection microwave oven with 762 mm instructions provided with the microwave trim E Series trim kit, and a Wolf warming drawer kit and warm
Resumo do conteúdo contido na página número 15
INSTALLATION INSTRUCTIONS STANDARD INSTALLATION OPTIONS E SERIES BUILT-IN DOUBLE OVEN Keep in mind that the size of the custom panel for the warming drawer with integrated The Wolf E Series double oven may be drawer front will vary according to the installed in combination with a Wolf warming specific installation. Refer to the installation drawer with E Series stainless steel drawer instructions provided with the warming drawer front or integrated drawer front. Refer to the front for detailed
Resumo do conteúdo contido na página número 16
WOLF E SERIES BUILT-IN OVENS ELECTRICAL REQUIREMENTS Verify that power is disconnected from The complete appliance must be properly the electrical box before proceeding. grounded at all times when electrical power is applied. NOTE: Improper connection can result in IMPORTANT a fire hazard. E SERIES SINGLE OVENS NOTE Required power supply: 220-240V AC, 50/60 Hz Be aware of local Open the terminal box to expose the screws codes and ordi- with corresponding numbers. Loosen the 1, 5, Maximum connect
Resumo do conteúdo contido na página número 17
INSTALLATION INSTRUCTIONS ELECTRICAL REQUIREMENTS INSTALLING THE OVEN With the oven positioned directly in front of UNPACK THE OV EN the cabinet opening, feed the properly rated cord attached to the oven terminal box through the opening in the cabinet platform Oven is not mounted to the shipping (where applicable). Then, depending upon base. Do not remove banding until the local codes, utilize one of the following tech- oven is at the point of installation. niques to connect the appliance to the
Resumo do conteúdo contido na página número 18
WOLF E SERIES BUILT-IN OVENS INSTALLING THE OVEN OVEN DOOR REMOVAL POSITION THE OV EN To reduce the weight of the oven and ease installation, removal of the oven door(s) is an The oven is very heavy—use caution option. when lifting. It is recommended that two people lift and position the oven into the opening. Wear gloves to protect hands To Remove Oven Door: from any sharp edges. Open oven door all the way. Flip down the hinge latch on each side. Holding the oven by the upper edge and Close the
Resumo do conteúdo contido na página número 19
INSTALLATION INSTRUCTIONS INSTALLING THE OVEN MOUNT OVEN TO CABINETRY OVEN OPERATION Once the oven is fully inserted into the cabinet IMPORTANT NOTE: Prior to operating the opening, locate the mounting holes on the oven, be sure to read the entire Wolf E Series oven side trim. There will be four mounting Built-In Ovens Use & Care Information holes for a single oven and six for a double included with the oven for important safety oven. Refer to the illustration below. Use a information. 2 mm dril
Resumo do conteúdo contido na página número 20
WOLF E SERIES BUILT-IN OVENS TROUBLESHOOTING IF YO U NEED SERVICE IMPORTANT NOTE: If the built-in oven does For service in your area, contact either your not operate properly, follow these trouble- Wolf dealer or visit the Showroom Locator shooting steps: section of our website, wolfappliance.com to find the regional distributor by country. Verify that power is being supplied to the oven. When calling for service, you will need the CONTACT built-in oven model and serial numbers. Check the elect