KBII-USER Rev D
User’s Information Manual
Models: 81 - 286
WARNING
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or
loss of life.
This appliance MUST NOT be installed in any location where
gasoline or flammable vapors are likely to be present.
WHAT TO DO IF YOU SMELL GAS
� Do not try to light any appliance.
� Do not touch any electric switch; do not use any phone in your
building.
� Immediately call your
Resumo do conteúdo contido na página número 2
Contents HAZARD DEFINITIONS .................................................... 2 3. OPERATING INSTRUCTIONS ..................................... 9 PLEASE READ BEFORE PROCEEDING ........................ 3 4. SMART SYSTEM CONTROL MODULE 1. PREVENT COMBUSTION AIR CONTAMINATION..... 4 SMART SYSTEM Control Module ................................... 10 2. MAINTENANCE SCHEDULE ....................................... 5 Access Modes ............................................................ 1
Resumo do conteúdo contido na página número 3
User’s Information Manual Please read before proceeding The Knight Boiler Installation and Boiler service and maintenance – NOTICE Operation Manual along with the Knight � To avoid electric shock, disconnect electrical supply Boiler Service Manual are for use only before performing maintenance. by a qualified heating installer/service � To avoid severe burns, allow boiler to cool before technician. Refer only to this User’s performing maintenance. Information Manual for you
Resumo do conteúdo contido na página número 4
User’s Information Manual 1 Prevent combustion air contamination If the boiler combustion air inlet is located WARNING Table 1 Corrosive Contaminants and Sources in any area likely to cause contamination, or if products which would contaminate Products to avoid: the air cannot be removed, you must have the combustion air and vent re-piped Spray cans containing chloro/fluorocarbons and terminated to another location. Contaminated combustion air will damage Permanent wave solu
Resumo do conteúdo contido na página número 5
User’s Information Manual 2 Maintenance schedule Owner maintenance Service technician (see pages 6 - 8 for detailed instructions) (see the Knight Boiler Service Manual) • Check boiler area General: • Reported problems • Check pressure/temperature gauge • Inspect interior; clean and vacuum if Daily necessary • Clean condensate trap and fill with fresh water • Check for leaks (water, gas, flue, condensate) • Check vent piping • Verify flue and air lines in good co
Resumo do conteúdo contido na página número 6
User’s Information Manual 2 Maintenance schedule Read the list of potential materials listed in Table 1 on Maintenance procedures page 4 of this manual. If any of these products are in the room from which the boiler takes its combustion air, they Boiler must be serviced and maintained must be removed immediately or the boiler combustion air (and vent termination) must be relocated to another The boiler must be inspected and started WARNING area. annually at the beginni
Resumo do conteúdo contido na página número 7
User’s Information Manual 2 Maintenance schedule (continued) 3. Fill with fresh water until the water begins to pour out of Use materials approved by the authority NOTICE the drain. having jurisdiction. In the absence of other authority, PVC and CPVC pipe 4. Replace the cap. Press the cap onto the trap until the cap must comply with ASTM D1785 or D2845. makes contact with the drain. Cement and primer must comply with 5. Replace the retaining screw. ASME D2564 or F493. F
Resumo do conteúdo contido na página número 8
User’s Information Manual 2 Maintenance schedule Check air vents Have leaks fixed at once by a qualified WARNING service technician. Failure to comply could 1. Reference FIG. 3 below. result in severe personal injury, death, or substantial property damage. 2. Visually inspect vent to make sure that no leaks are 3. Replace the front access door. present. 3. If there is leaking, tighten the pin valve. Operate relief valve 4. If the leak continues, replace the air vent. 1. Bef
Resumo do conteúdo contido na página número 9
User’s Information Manual 3 Operating instructions o C 9
Resumo do conteúdo contido na página número 10
User’s Information Manual 4 SMART SYSTEM control module Knight boiler control module Use the control panel (FIG. 4) to set temperatures, operating conditions, and monitor boiler operation. Figure 4 Control Panel NAVIGATION DIAL The information on the bottom of the display shows the functions of the two SELECT keys (on either corner), and the NAVIGATION dial (in the center): MENU = Left SELECT Key SETPOINTS = NAVIGATION Dial - Pressing Down SHDN = Right SELECT Key
Resumo do conteúdo contido na página número 11
User’s Information Manual 4 SMART SYSTEM control module (continued) Night Setback Override Space heating (SH1, SH2, SH3) and tank set points Any Night Setback On trigger currently active or scheduled Mixing valves are required for the within the next seven (7) days can be skipped. To skip a CAUTION protection of any low temperature loops. trigger, rotate the NAVIGATION dial until the arrow (>) is next to the trigger you wish to skip. Press the NAVIGATION dial once. “SK” wil
Resumo do conteúdo contido na página número 12
User’s Information Manual 4 SMART SYSTEM control module Figure 5 Status Display Screen B A (CALL FOR (BOILER HEAT) STATUS) C (OPERATIONAL INFORMATION) F D (RIGHT SELECT KEY) (LEFT SELECT KEY) E (NAVIGATION DIAL) Status Display Screens Section Display Description The unit has not received a call for heat from a remote thermostat nor STANDBY has it received a call for heat from a DHW thermostat. START The unit has begun a burn cycle and is checking all safety circuits. PREPURGE The
Resumo do conteúdo contido na página número 13
User’s Information Manual 4 SMART SYSTEM control module (continued) Status Display Screens (cont’d) Section Display Description SYSTEM: The temperature read by the system supply sensor (if connected). TANK: The temperature read by the tank sensor (if connected). OUTDOOR: The temperature read by the outdoor sensor (if connected). INLET TEMP: The temperature read at the inlet to the heat exchanger. OUTLET TEMP: The temperature read at the outlet of the heat exchanger. The temperature di
Resumo do conteúdo contido na página número 14
User’s Information Manual 4 SMART SYSTEM control module Status Display Screens (cont’d) Section Display Description Press and hold the LEFT SELECT key for 5 seconds to enter the Menu MENU Screen. EXIT Press the LEFT SELECT key to exit the current screen or setting. Press the LEFT SELECT key to confirm that the boiler needs to YES D shutdown. (LEFT SELECT Press the LEFT SELECT key to enter the screen that allows you to LIMITS key function) adjust the limit settings. Press the LEFT
Resumo do conteúdo contido na página número 15
User’s Information Manual Notes 15
Resumo do conteúdo contido na página número 16
Revision Notes: Revision A (ECO C05747) initial release. Reflects the new model numbers for the Knight upgrade. Revision B (ECO C07072) reflects the change in design of manual air vent valve and the update of FIG. 3 on page 8. Revision C (ECO #C09197) updates made to the SMART SYSTEM control (ECR #R04523). Revision D (ECO #C10143) reflects updates made to the ignition timing information. KBII-USER Rev D 04/12