Resumo do conteúdo contido na página número 1
ACCULINK 3165 DSU/CSU
QUICK REFERENCE
Document No. 3165-A2-GL11-30
Resumo do conteúdo contido na página número 2
Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue
Resumo do conteúdo contido na página número 3
TM ACCULINK 3165 DSU/CSU Quick Reference Document Number 3165-A2-GL11-30 January 1998 Quick Start Procedure The following procedure is for experienced DSU/CSU users who are familiar with the 3165 DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 316x Data Service Unit/Channel Service Unit Operator’s Guide (Document No. 3160-A2-GB21) for more information. 1. Attach the power cord to the rear of the DSU/CSU and the other end to a grounded 115 Vac
Resumo do conteúdo contido na página número 4
Modem PSTN Modem or or PC Terminal SNMP Manager Workstation Front Modem Modem Panel 3165 DSU/CSU COM Network Port Port Port Port 3165 COM PORT MODEM NETWORK POWER AUX PORT DTE DSU/CSU NEC CLASS 2 CAUTION: AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK Network INPUT Port T1 Network COM Port Power Serial COM PORT MODEM NETWORK POWER AUX PORT DTE 3165 Port NEC DSU/CSU CLASS 2 CAUTION: AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK INPUT Power Network or Port
Resumo do conteúdo contido na página número 5
Configuration Options Configuration options are accessed from the Configuration branch of the front panel menu. DSU ESF Stat Test Cnfig Ctrl Rel DevHS STest Perf TStat LED ID Reset Passwd Call ClrReg CID DL Telco User Prtn T1 Prtn Near Far Dial Disc ChDir Rlpbk Lpbk Ptrns Lamp Cur Intvl User Prt1 24Tot Cur Intvl 1 . . 5,A 1 . . 5,A Near Far 8Tot Abort Send Mon (Directory) (Directory) QRSS 511 LLBUP 54UP FT1UP LLBDN 54DN FT1DN QRSS 1in8 511 Abort LLB PLB DLB RLB DCLB DTLB Load Edit Area From: Act
Resumo do conteúdo contido na página número 6
Table 1. Port Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description E530 E530 V.35 V.35 Selects the Selects the por port t t type: ype: EIA-530A, EIA-530A, Port T Port Type: ype: V.35, RS449, or X.21. RS449 RS449 X.21 X.21 Nx64 Nx64 E Enables the nables the por port to either Nx56 or t to either Nx56 or Base Base Rate: Rate: Nx64 rates. Nx56 Nx56 Disab Disab V.54 V.54 Network-initiated DCLB, allows , Net Net DCLB: DCLB: DCLB DCLB to be controlled by inband to be contro
Resumo do conteúdo contido na página número 7
Table 1. Port Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description 10E–4 10E–4 10E–5 10E–5 Err Rate: 10E–6 10E–6 Selects the error rate threshold for (Excessive (Excessive Error Error Excessive Excessive Error Rate Alarm. Error Rate Alarm 10E–7 10E–7 Rate) ae) 10E–8 10E–8 10E–9 10E–9 Table 2. Network Interface Configuration Options Option Factory 1 Factory 2 Comments/Description D4 D4 NET Framing: Selects D4 or ESF framing format NET Framing: Selects D4 or ESF frami
Resumo do conteúdo contido na página número 8
Table 3. Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description Block Block Determines how channels are Determines how channels are ACAMI ACAMI Assign By: Assign By: assigned: contiguous blocks, assigned: contiguous blocks, ACAMI ACAMI or individual channels. i di id l h l Chan Chan Option Factory 1 Factory 2 Comments/Description 64 (56) 64 (56) 128 (112) 128 (112) 192 (168) 192 (168) 256 (224) 256 (224) 320 (280) 320 (280) 384 (336) 384 (336) 448 (392) 448 (392
Resumo do conteúdo contido na página número 9
Table 3. Channel Configuration Options (2 of 2) Clears (unassigns) channels for Clear Clear this port. N1 (D1) N1 (D1) N2 (D2) N2 (D2) N3 (D3) N3 (D3) N4 (D4) N4 (D4) N5 (D5) N5 (D5) N6 (D6) N6 (D6) N7 (D7) N7 (D7) N8 (D8) N8 (D8) N9 (D9) N9 (D9) N10 (D10) N10 (D10) N11 (D11) N11 (D11) Start At: This configuration option appears if N12 (D12) N12 (D12) the “Assigned By” configuration N13 (D13) N13 (D13) option is Block or ACAMI. N14 (D14) N14 (D14) N15 (D15) N15 (D15) N16 (D16) N16 (D16) N17 (D
Resumo do conteúdo contido na página número 10
Table 4. General Configuration Options Option Factory 1 Factory 2 Comments/Description Enab Enab Gen Y Gen Yellow: ellow: Y Yellow alarm is ellow alarm is genera generated b ted by y the the (Generate Yellow) DSU/CSU on LOS, LOF, or AIS. Disab Disab NET NET DTE DTE Selects Selects the clock source to be the clock source to be Prt1 Prt1 Clock Src: Clock Src: used as the master clock for the used as the master clock for the DSU/CSU. DSU/CSU Int Int Ext Ext 2048 2048 Selects the clock rate of the
Resumo do conteúdo contido na página número 11
Table 5. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Enab Enab Allows bypass of self-test on Allows bypass of self-test on Self-T Self-Test: est: initialization. Disab Disab Enab Enab Controls Controls whether front panel whether front panel FP Access: FP Access: access or display is allowed. Disab Disab Enab Enab Controls whether front panel Controls whether front panel FP Pass: FP Pass: pass-through is allowed. Disab Disab Enab Enab Controls Controls w
Resumo do conteúdo contido na página número 12
Table 5. User Configuration Options (2 of 3) Option Factory 1 Factory 2 Comments/Description 1 1 CStop CStop Bits: Bits: Selects the number of stop bits for 1.5 1.5 (Communication Port (Communication Port the COM the COM por port. t. Stop Bits) St Bit ) 2 2 Yes Yes S Spec pecifies whether the COM ifies whether the COM por port t Ignore DTR: Ignore DTR: ignores DTR. No No Enab Enab CmInActTm: Specifies whether the p (COM (COM Port Inactivity Port Inactivity communication communication port disc
Resumo do conteúdo contido na página número 13
Table 5. User Configuration Options (3 of 3) Option Factory 1 Factory 2 Comments/Description 5 5 MoDiscTm: Up Up Specifies the period of inactivity Specifies the period of inactivity (M (Modem Port odem Port (1 (1 to 60 minutes) that causes a t 60 i t ) th t Disconnect Time) Down Down d disconnect if MInActTm is enabled. sco ec c s e ab ed Save Save Enab Enab Specifies whether the DSU/CSU p TnSession: TnSession: responds responds to T to Telnet elnet session session (Telnet Session) Disab D
Resumo do conteúdo contido na página número 14
Table 6. Alarm Configuration Options Option Factory 1 Factory 2 Comments/Description Disab Disab Does not display alarm messages. Sends alarm messages to Modem Modem Modem port. Al Alrm Msg: M Sends alarm messages to COM Com Com port. Sends alarm messages to both Both Both ports. Enab Enab SNMP SNMP T Trap: rap: Sends Sends SNMP traps. SNMP traps Disab Disab Enab Enab Specifies whether the modem p T TrapDisc: rapDisc: connection will disconnect after a connection will disconnect after a Disab
Resumo do conteúdo contido na página número 15
Table 7. Management – General Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description Disab Disab Specifies whether the DSU/CSU p SNMP SNMP Mgt: Mgt: responds to SNMP session responds to SNMP session Enab Enab requests. Specifies whether the DSU/CSU Disab Disab validates validates the IP address of an the IP address of an NMS V NMS Valid: alid: SNMP manager attempting Enab Enab access. The number of management 1 1 Num Sec Mgrs: systems authorized to send SNMP 2–10 2–10 m
Resumo do conteúdo contido na página número 16
Table 7. Management – General Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Edit Edit The Subnet Mask needed to Com NetMask: Com NetMask: access access the device when the COM the device when the COM Clear Clear port is configured for SNMP. PPP PPP The link layer protocol for the COM The link layer protocol for the COM Com Link: Com Link: port when configured for SNMP. SLIP SLIP Edit Edit Specifies the IP address for the p Modem Modem IP Adr: IP Adr: MODEM MODE
Resumo do conteúdo contido na página número 17
Table 8. Management – Trap Configuration Options Option Factory 1 Factory 2 Comments/Description 1 1 The number of trap managers Num Trap Mgrs: 2–6 2–6 supported by the device. Specifies the IP address for each Edit Edit trap trap manager manager. This configuration . This configuration T Trap rapn n IP Adr: IP Adr: option is repeated for all n Clear Clear managers. None None Def Def Trapn Dst: Specifies the network destination Com Com f for T or Trap rap Mana Manager ger n n. . Modem Modem F
Resumo do conteúdo contido na página número 18
Notes 16