Resumo do conteúdo contido na página número 1
DPoE™ Power Patch Panel
User’s Guide
Part Numbers: DPOE24U1X, DPOE24U1XY,
DPOE12U1X, DPOE12U1XY, DPOE24S1X,
DPOE24S1XY
Issue 2.2
Part Number: PN378A
August 2006
© 2006 PANDUIT Corp.
All Rights reserved
www.panduit.com
Resumo do conteúdo contido na página número 2
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A Safety Warning Always observe standard safety precautions during installation, operation and maintenance of this product. Read the installation instructions before you connect the unit to its power source. This unit must be connected to earth ground, do not bypass the grounding system. To avoid the possibility of electric shock, disconnect the power cord from the power source before removing the cover or per
Resumo do conteúdo contido na página número 3
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A TABLE OF CONTENTS Safety Warning................................................................................................................. i WARRANTY..................................................................................................................... i TRADEMARKS ................................................................................................................ i OVERVI
Resumo do conteúdo contido na página número 4
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A Refresh the Network........................................................................................... 43 Administering E-mail Settings............................................................................. 43 Search for Specific Panel(s) or Port(s) ............................................................... 45 EM Log Messages...................................................................
Resumo do conteúdo contido na página número 5
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A Table 14: Package Contents......................................................................................... 53 Table 15: PANDUIT Corp Contact Information.............................................................. 54 Table 16: Color-Coded Wire Positions for 802.3af-2003 Compliant Devices ................ 57 Table 17: Color-Coded Wire Positions for Alternate PoE Devices ...............................
Resumo do conteúdo contido na página número 6
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A OVERVIEW The DPoE™ Power Patch Panel provides a reliable and cost-effective solution for Power over Ethernet (PoE) applications, complaint with the IEEE 802.3af-2003 specifications. Each DPoE™ Power Patch Panel allows centralized powering of up to 24 devices, such as Internet Protocol-based (IP) telephones, Network Security Cameras, or Wireless Devices, over the same cabling used to provide the Ethernet conn
Resumo do conteúdo contido na página número 7
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A OUT management A- and B-feed port and OUT Punchdown (optional) Power Network Status LED connections Connections IN management port and IN Network Status LED Figure 2: DPoE™ Power Patch Panel (Rear View) Features and Benefits The following table highlights some of the capabilities of the DPoE™ Power Patch Panel along with the tangible benefit to the network operator. DPoE™ Power Patch Panel
Resumo do conteúdo contido na página número 8
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A DPoE™ Power Patch Panel Feature Benefit IEEE 802.3af-2003 Compliant Many currently available in-line PoE powering options are not standards-based, thus requiring coordination between each device’s power needs and the technical capabilities of the in-line powering unit. Any port on the PANDUIT® DPoE™ Power Patch Panel can support the 802.3af-2003 standard or the legacy Cisco powering scheme. Full powe
Resumo do conteúdo contido na página número 9
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A DPoE™ Power Patch Panel Feature Benefit Easier Installation By eliminating the need for separate midspan patch panels and the associated need for patch cord, in a network-ready 1RU high package, The DPoE™ Power Patch Panel is fast and easy to install. INSTALLATION For DPOE24U1X, DPOE24U1XY, DPOE12U1X and DPOE12U1XY (For DPOE24S1X and DPOE24S1XY see Appendix 1) The PANDUIT® DPoE™ Power Patch Panel requi
Resumo do conteúdo contido na página número 10
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A Item Quantity Notes Quick Installation Instructions 1 PANDUIT Part Number PN370 DPOE™ Installation Worksheet 1 PANDUIT Part Number PN377 Metric and English screws 12 Installation requires six screws. One bag of six metric screws (M6x1.0x16) and one bag of six English screws (12-24x1/2”) are included. 8 inch grounding strap 1 DPoE™ Power Patch Panel Support Tools CD- 1 ROM containing: ® - PANDUIT
Resumo do conteúdo contido na página número 11
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A IMPORTANT: The DPOE™ Installation Worksheet should be used to record pertinent information when installing DPoE™ Power Patch Panel(s), particularly if the EM is monitoring the network. (See page 29, Provisioning the Panel, for more information on how this information will be entered in the EM.) The installer should complete this worksheet. Panel Mounting Procedure WARNING: Only trained and qualified s
Resumo do conteúdo contido na página número 12
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A Grounding Requirements Network Connection 5. If the Element Manager is not being used to remotely manage the network of DPoE™ Power Patch Panels, skip to Connecting the Powered Devices below. Otherwise, using a standard patch cord (for example, PANDUIT part number UTPCH3 or UTPSP3), connect the IN management port on the back of the panel to an Ethernet switch. A DHCP Server must b
Resumo do conteúdo contido na página número 13
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A 8. Fan out all four twisted pairs in the specified wiring sequence (see color-coded wiring positions in Table 4: Color-Coded Wire Positions for 802.3af-2003 Compliant Devices and Table 5: Color-Coded Wire Positions for Alternate PoE Devices below). The colors are also displayed on the Wiring Template Label, already installed on the back of the DPoE™ Power Patch Panel. NOTE: The DPoE™ Power Patch Pane
Resumo do conteúdo contido na página número 14
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A 9. Lay conductors into the punchdown slots for the specified port using the correct wiring sequence. Cable jacket removal should be minimized to the extent possible. Conductor untwist should be within ½” (12.7 mm) of termination. WARNING: NEVER TOUCH UNINSULATED COMMUNICATIONS WIRING OR TERMINALS UNLESS THE COMMUNICATION LINE HAS BEEN DISCONNECTED AT THE NETWORK INTERFACE. NOTE: Never i
Resumo do conteúdo contido na página número 15
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A WARNING: The power supply connections are polarized. The DPoE™ Power Panel will not function if power is wired improperly. For Maximum power the overall length of the wire between the power supply and the DPoE™ Power Panel must not exceed 35 feet. NOTE: The included power harness has two wires for the A-feed power only (pins 1 & 2). The DPoE™ Power Patch Pane
Resumo do conteúdo contido na página número 16
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A Table 6: DPoE™ Power Patch Panel Power Up Sequence Behavior as viewed from the back of the unit Behavior as viewed from the front of the unit Both network status LEDs will light amber for two The panel status Light-Emitting Diode (LED) will seconds light red for about 10 seconds. After that, a LED test sequence of the port status LEDs will take place, lighting each port status LED amber. It will appear
Resumo do conteúdo contido na página número 17
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A Table 7: Basic Troubleshooting Guide Problem Possible Causes and Solutions The panel status LED does not light when power 1. The power supply fuse may be blown. Check is applied to the unit. the fuse on the DPoE™ Power Patch Panel power supply. 2. The power connection may be bad. Check the physical connection and make sure the voltage polarity is proper. 3. No power is available at the panel. Make sure
Resumo do conteúdo contido na página número 18
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A OPERATION LED Indicators The DPoE™ Power Patch Panel displays system and port status through the use of LEDs on the front and rear of each panel. There is one panel status LED on the front left of the panel, 24 individual port status LEDs above each port, and twonetwork status LEDs on the rear of the unit. These LEDs enable the technician to see at a glance if either the ports or the panel itself is in ala
Resumo do conteúdo contido na página número 19
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A LED Color Port LED Status Description Status of Power Ports Red Solid The system has failed to determine Power is NOT being the PD power requirements for this delivered down this port on port. Perhaps this PD is not an the panel. 802.3af-2003 compliant or Cisco legacy power device. It could also be a port configured for 802.3af- 2003 and an alternate PoE device has been connected. Also, pins (4,5) &
Resumo do conteúdo contido na página número 20
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2 Part Number: PN378A ELEMENT MANAGER SOFTWARE ® The optional PANDUIT Element Manager is used to remotely control, configure and monitor the DPoE™ Power Patch Panels within the network. Once installed on a shared or dedicated Windows-based Personal Computer (PC), the EM can be used to manage an entire network of DPoE™ Power Patch Panels. ® The PANDUIT Element Manager is shipped on a CD-ROM included with the DPoE™ Power Patch