Resumo do conteúdo contido na página número 1
Installation Installation Installation Guide
RAID 5 eSATA 3Gbps 2 external port Low profi le PCI Express card
GICe702S3R5W6
PART NO. M0557
1
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Table of Contents Caution 4 Introduction 6 Features 7 Package Contents 8 What Is RAID? 9 Installation Procedure 12 Software Installation 19 Verifying Controller Installation 22 Federal Communications Commission 23 (FCC) Statement CE Statement 25 Limited Warranty 26 Contact 27 3
Resumo do conteúdo contido na página número 4
Caution • Before installation of the controller card we recommend that users study this manual fi rst. This RAID manual has more information on RAID architecture, RAID features, RAID installation, RAID settings and Management software for the RAID5 GUI (Graphical User Interface). • Windows Device Manager cannot recognize hard drives without the correct RAID settings in place. • The working data on your existing hard drive may NOT work when you migrate it to a RAID Host Card confi guration.
Resumo do conteúdo contido na página número 5
• If you’re using a used hard drive with the RAID5 card you must perform the “Delete RAID Set” under the BIOS settings. The reason this is necessary is because the used hard drive has system data on it which may cause recognition issues when confi guring it for use with the RAID5 card. • RAID 0 and RAID1 setups require at least 2 drives, with RAID5 requiring 3 drives and RAID10 requiring 4 drives. • If one hard drive only, make sure to have “Concatenate” or “Contiguous” setting. • The set
Resumo do conteúdo contido na página número 6
Introduction The Low Profi le PCI-Express Host Adapter allows support for both Low profi le PCI and standard size PCI connections. The card offers the option of upgrading your desktop with a 2 port Serial ATA II transfer rate of up to 3 Gb/s. The board allows you the options of setting up RAID 5, RAID 0+1, RAID 0, or RAID 1 as well as JBOD within your system. 6
Resumo do conteúdo contido na página número 7
Features • External SATA II (eSATA) Connector. • 48 bits LBA can Break Capacity-Limit to Support HDD larger than 137GB. • Supports 1-lane 2.5Gbps PCI Express. • Hot-plug capability. • Supports SATA II transfer rate of 3.0Gbps. • Fully compliant with Serial ATA 1.0 specifi cations. • Supports two independent Serial ATA channels. • Independent Link, Transport, and data FIFO. • Independent command fetch, scatter/gather, and command execution. • Supports Legacy Command Queuing (LCQ). • Suppor
Resumo do conteúdo contido na página número 8
Package Contents • RAID5 SATA II – 3Gbps 2Port PCI Express Host Adapter • Low PCI Bracket • Quick Start Guide • Driver CD 8
Resumo do conteúdo contido na página número 9
What Is RAID? RAID - Redundant Array of Independent Disks RAID technology manages multiple disk drives to enhance I/O performance and provide redundancy in order to withstand the failure of any individual drive, without loss of data. Disk Striping (RAID 0) Striping is a performance-oriented, non-redundant data mapping technique. While Striping is discussed as a RAID Set type, it actually does not provide fault tolerance. With modern SATA bus technology, multiple I/O operations can be done in
Resumo do conteúdo contido na página número 10
Mirrored-Striping (RAID 0+1 also known as RAID 10) A Mirrored-Striping Set does just what it says, combining both Striping and Mirroring technologies to provide both the performance enhancements that come from Striping and the data availability and integrity that comes from Mirroring. When data is written to a Mirrored-Striped Set, instead of creating just one virtual disk as Striping would do, a second Mirrored virtual disk is created as well. Parity RAID (RAID 5) Parity or RAID 5 adds fau
Resumo do conteúdo contido na página número 11
Just a Bunch of Disks (JBOD/Contiguous) JBOD (also known as Contiguous) means a logical drive that can either be an entire disk drive or a segment of a single disk drive. For this card, the JBOD function only supports one disk. JBOD here is a Contiguous confi guration option when using the “Create RAID Group” within the SATARAID5 Manager Utility. 11
Resumo do conteúdo contido na página número 12
Installation Procedure 1. Power down the computer system. 2. Insert the Host card into an available bus slot. 3. Power on the computer system. 4. Install drivers for the device. 5. Remove all existing SATARAID GUIs (or Java SATARAID GUIs) to ensure your new SATARAID5 GUI installs and functions properly. 6. Install the SATARAID5 GUI. 7. Power down the computer system once again. 8. Connect Hard Drives to the proper SATA Ports. 9. Power on the computer system once again. 10. If you conne
Resumo do conteúdo contido na página número 13
11. Use the SATARAID5 Manager GUI to confi gure your RAID settings. If using 1 Disk, please select “Concatenate” or “Contiguous” settings only. If using 2 Disks, do NOT select “Parity RAID” or “Mirrored Stripe” settings. If using 3 Disks, do NOT select the “Mirrored Stripe” setting. 12. Open “Task Manager” to make sure the RAID setup is completed. RAID5 can take hours to complete, please be aware of these time requirements. 13. Use Device Manager for hard disk initialization,
Resumo do conteúdo contido na página número 14
BIOS (RAID Settings) Creating and deleting RAID sets is a function found in the BIOS. During boot up, the RAID setting message will appear and pause for a few moments to allow the user access to its settings. The board will act as a normal NON-RAID card when the BIOS does not have it confi gured for RAID. If you’re using traditional parallel ATA HDDs, make sure your hard drives are set to master mode before accessing the RAID settings. Creating Striped Sets (RAID 0) 1. As the BIOS boots, Pre
Resumo do conteúdo contido na página número 15
5. Select RAID size. Press Enter. 6. Press Y to save your settings. 7. Press CTRL+E and then press Y to exit the setup. 8. Continue with conventional Fdisk and Format steps to prepare the hard drives. 9. Your RAID hardware confi guration is complete. Proceed to software installation section. Creating Mirrored Sets (RAID 1) 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select RAID 1 then press Enter. 4. Select Auto con
Resumo do conteúdo contido na página número 16
Creating a Mirrored-Striped Set (RAID 10) 1. As the BIOS boots, press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press F2. 3. Select RAID 10 then press Enter. 4. Select Auto confi guration. Press Enter. 5. Press Y and then press ESC to exit the setup. 7. Continue with conventional Fdisk and Format steps to prepare the hard drives. 8. Your RAID hardware confi guration is complete. Proceed to software installation section. Creating Parity RAID (RAID 5) 1. As the
Resumo do conteúdo contido na página número 17
Creating JBOD Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select JBOD (Single) then press Enter. 4. Select JBOD Drives. Press Enter. 5. Select RAID size. Press Enter. 6. Press Y to save your settings. Creating Spare Drive 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Create RAID set. Press Enter. 3. Select Spare Drive then press Enter. 4. Select Spare Drives. Press Enter
Resumo do conteúdo contido na página número 18
Deleting RAID Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility. 2. Select Delete RAID set. Press Enter. 3. Answer Y to remove the RAID set. If the RAID set being deleted is a Striped, then all of the data will be lost. If the set being deleted is a Mirrored set, then the data will remain intact and accessible on both drive sets. Rebuilding Mirrored Sets (RAID 1) 1. After replacing the failed hard drives boot the BIOS, Press CTRL+S or F4 to enter the RAID bios ut
Resumo do conteúdo contido na página número 19
Software Installation Windows XP Fresh Installation 1. Power off the system. Insert the controller card into a PCI slot and connect the hard drives to the controller card. Power up the system. 2. Put your Windows XP CD into the CD-ROM/DVD drive. 3. Press F6 for third party SCSI or driver installation. Press ‘S’ when setup asks if you want to specify an additional device. Press ‘Enter’ and select ‘[CD Drive Letter]:\ SATA PCIe_ Raid5_2Port \SiI3132\Windows\Driver’. 4. Press ‘Enter’ to cont
Resumo do conteúdo contido na página número 20
Windows XP Existing Installation 1. Power off the system. Insert the controller card into a PCI slot and connect the hard drives to the controller card. Power up the system. 2. During OS boot up, Windows will display the ‘Found New Hardware Wizard’. Click ‘Next’. 3. Select ‘Install from a list or specifi c location (Advanced)’ and Click ‘Next’. 20