Resumo do conteúdo contido na página número 1
Operator’s Manual
Stratos™Portable Plus
Compressor Nebulizer
System
Model Number: IRC 1730
Dealer: This manual MUST be given to the end user.
User: BEFORE using this product, read this manual and save
for future reference.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com
Resumo do conteúdo contido na página número 2
WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE, INJ
Resumo do conteúdo contido na página número 3
TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ...............................................5 INTRODUCTION ..............................................6 REGISTER YOUR PRODUCT ..............................7 FEATURES .......................................................8 TYPICAL PRODUCT PARAMETERS ...................9 SUPPLEMENTAL INFORMATION ..................... 10 Compressor........................................................................................10 Extension Cords......
Resumo do conteúdo contido na página número 4
TABLE OF CONTENTS TABLE OF CONTENTS Battery Specifications .......................................................................21 Conditioning the Battery.................................................................23 Using the Battery...............................................................................24 Charging the Battery ........................................................................25 SECTION 4—CLEANING AND DISINFECTING ... 26 Cleaning the Nebulizer ..............
Resumo do conteúdo contido na página número 5
SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the table below for definitions of the signal words. SIGNAL MEANING WORD Danger indicates an imminently hazardous situation which, if DANGER not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if WARNING not avoided, could result in death or serious injury. Caut
Resumo do conteúdo contido na página número 6
INTRODUCTION INTRODUCTION Your Invacare Stratos Portable Plus Compressor Nebulizer System is the latest in portable compressor nebulizer technology. The purpose of the nebulizer system is to convert your liquid medication into a fine mist that can be drawn into your lungs to relieve your respiratory condition. The nebulizer system is very portable and lightweight. For even greater convenience, ask your dealer about the optional battery pack that is sold separately. To maximize your benefi
Resumo do conteúdo contido na página número 7
REGISTER YOUR PRODUCT REGISTER YOUR PRODUCT The benefits of registering include: 1. Safeguarding your investment. 2. Ensuring long-term maintenance and servicing of your product. 3. Receiving updates with product information, maintenance tips and industry news. Register ONLINE at warranty.invacare.com Please have your model number and purchase date available to complete your registration. Any registration information you submit will only be used by Invacare Corporation and protected as requi
Resumo do conteúdo contido na página número 8
FEATURES FEATURES Compressor Outlet On/Off Button Inlet Air Filter AC/DC Power Outlet Stratos™Portable Plus 8 Part No 1150755
Resumo do conteúdo contido na página número 9
TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS SOUND LEVEL: 58 dBA OPERATING 50°F - 104°F (10°C to 40°C); 10 to 95% RH TEMPERATURE RANGE: FOAM INTAKE FILTER: Expanded Polyurethane SAFETY SYSTEMS: High temperature compressor shutdown. REGULATORY LISTING: In compliance with EN 60601-1 DIMENSIONS WITHOUT BATTERY: 5.1 x 3.6 x 1.6 inches (13cm x 9cm x 4cm) WITH BATTERY: 5.1 x 3.6 x 2.6 inches (13cm x 9cm x 7cm) *WEIGHT WITHOUT BATTERY: 1 lbs (450 g) WITH BATTERY: 1.4 lbs (650 g) POWER SUPPLY
Resumo do conteúdo contido na página número 10
SUPPLEMENTAL INFORMATION SUPPLEMENTAL INFORMATION Compressor If the unit shuts down frequently or fails to start, you may have a low voltage situation. Low voltage can also be suspected when: •The compressor fails to start or motor does not get up to full power or speed. •Other motor operated appliances fail to operate properly or too many motor operated appliances are on same circuit. Extension Cords Make certain extension cord is in good condition. Make certain extension cord wire is NO
Resumo do conteúdo contido na página número 11
HANDLING HANDLING Shipping Instructions The shipping container has been designed to assure protection of this device. If this device is to be reshipped by common carrier, it should be packed in the same carton. Unpacking 1. Check for any obvious damage to the carton or its contents. If damage is evident, DO NOT use. Notify carrier/Invacare or your local Invacare dealer. 2. Remove all the loose packing from the carton. 3. Carefully remove all the components from the carton. NOTE: Retain carto
Resumo do conteúdo contido na página número 12
SECTION 1—IMPORTANT SAFEGUARDS SECTION 1—IMPORTANT SAFEGUARDS WARNING SECTION 1 - IMPORTANT SAFEGUARDS contains important information for the safe operation and use of this product. CAUTION “Caution: Federal law restricts this device to sale or rental by or on order of a physician, or any other practitioner licensed by the law of the State in which he/she practices to use or order the use of this device.” When using electrical products, especially when children are present, basic safet
Resumo do conteúdo contido na página número 13
SECTION 1—IMPORTANT SAFEGUARDS DANGER Risk of electric shock. DO NOT disassemble. Refer servicing to qualified service personnel. FIRE RISK ‐ DO NOT use this product in an oxygen enriched environment (i.e – oxygen tent). To Reduce the Risk of Electrocution: ALWAYS unplug this product IMMEDIATELY after using. DO NOT use while bathing. DO NOT place or store product where it can fall or be pulled into a tub or sink. DO NOT reach for product that has fallen into water. Unplug IMMEDIATELY. DO N
Resumo do conteúdo contido na página número 14
SECTION 1—IMPORTANT SAFEGUARDS WARNING To Reduce the Risk of Burns, Electrocution, Fire and Injury to Persons: This product should NEVER be left unattended when plugged in. Close supervision is necessary when this product is used by, on, or near children and physically challenged individuals. Use this product only for its intended use as described in this manual and only with the prescribed medication. Use this product only under physician’s direction. NEVER operate this product with a da
Resumo do conteúdo contido na página número 15
SECTION 1—IMPORTANT SAFEGUARDS WARNING NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free from lint, hair and the like. Blocked openings may cause the unit to shut down. Contact dealer IMMEDIATELY. The Stratos Portable Plus Compressor Nebulizer System uses the surrounding air to effectively administer the prescribed medication through the nebulizer. The user and administrator
Resumo do conteúdo contido na página número 16
SECTION 1—IMPORTANT SAFEGUARDS WARNING When not administering treatment, keep out of the reach of small children. Some of the parts of the nebulizer system are small enough for children to swallow. The tubing may present a strangulation hazard NEVER touch the unit with wet hands. DO NOT pull on the power cord to unplug the unit from an electrical outlet. DO NOT overload wall outlets. Pump maintenance MUST be performed by a qualified service technician. SAVE THESE INSTRUCTIONS Stratos™Port
Resumo do conteúdo contido na página número 17
SECTION 2—OPERATING INSTRUCTIONS SECTION 2—OPERATING INSTRUCTIONS WARNING Remove the compressor from the carrying case before use. DO NOT operate unit without filter. Avoid operating this product in a dusty environment. Otherwise, premature compressor wear could occur. Setup NOTE: For this procedure, refer to FIGURE 2.1 on page 18. 1. Wash your hands before you begin the treatment procedure. 2. Place the device on a table so that the controls can be reached when seated. 3. Open the nebuli
Resumo do conteúdo contido na página número 18
SECTION 2—OPERATING INSTRUCTIONS WARNING DO NOT exceed the maximum allowed quantity of six ml of medication. The maximum capacity of the nebulizer medication cup is 6 ml. CAUTION NEVER pour medication into the compressor outlet. Damage to the compressor will occur. 5. Add the prescribed Eyedropper amount of medication to Nebulizer the cup of the nebulizer Cup using an eyedropper, pre‐measured dose or ampoule (FIGURE 2.1). FIGURE 2.1 Adding 6. Close the nebulizer. Medication 7. Attac
Resumo do conteúdo contido na página número 19
SECTION 2—OPERATING INSTRUCTIONS 10.To use with battery, charge for 6 hours. Refer to Conditioning the Battery on page23. 11.To use the nebulizer system with the AC power cord, connect the power cord plug into the power outlet on the side of the nebulizer compressor system. Connect the power cord to the AC adapter and insert the plug from the AC adapter into the electrical outlet. 12.To use the nebulizer system with the DC auto adapter, connect the DC auto adapter to the power outlet on th
Resumo do conteúdo contido na página número 20
SECTION 2—OPERATING INSTRUCTIONS 1. Sit in a relaxed and upright position. 2. Turn on the device by pushing the On/Off button. 3. Begin treatment by placing the nebulizer mouthpiece between your teeth and close your mouth. Inhale deeply and slowly as the aerosol begins to flow and then exhale slowly. FIGURE 2.2 Using the 4. When treatment is Nebulizer completed, turn off the nebulizer system and unplug the power adapter. 5. Remove the mouthpiece from the nebulizer. 6. Remove the n