Resumo do conteúdo contido na página número 1
®
CompactPCI
Multi-Function Adapters
Installation and User’s Guide
Order Number ITI-90-100250
Version 1.2 (Second Publication)
LSI Logic Copyright 2000
Resumo do conteúdo contido na página número 2
Copyright 2000 Second Printing, August 2000 The information in this document is subject to change without notice and should not be construed as a commitment by LSI Logic/IntraServer Technology, Inc. LSI Logic/IntraServer Technology, Inc. assumes no responsibility for any errors that may appear in this document. Version Date Comments Version 1.1 January 2000 First Version Version 1.2 August 2000 Added SunCluster™ Cable Configurations Page 2 of 83
Resumo do conteúdo contido na página número 3
The, software, if any, described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. No responsibility is assumed for the use or reliability of software or equipment that is not supplied by IntraServer Technology, Inc. or its affiliated companies. Copyright© IntraServer Technology, Inc., 2000. All Rights Reserved. The Reader’s Comment form at the end of this document requests your critical evaluation to assist in preparing f
Resumo do conteúdo contido na página número 4
FCC NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Oper
Resumo do conteúdo contido na página número 5
FCC Declaration of Conformity ® The IntraServer Technology, Inc. CompactPCI Ultra2 SCSI, Video and Ethernet adapter, model numbers ITI-8241, ITI-8240, ITI-8200, ITI-8040 and ITI-8001 comply with the requirements of FCC part 15, class A as defined under paragraph 2.909 of these rules. This declaration covers products identified with ITI-8241, ITI-8240, ITI-8200, ITI-8040 and ITI-8001 on the product label. A copy of the test report substantiating compliance is available on request from: Corporate
Resumo do conteúdo contido na página número 6
Table of Contents TABLE OF CONTENTS ...............................................................................6 INTRODUCTION..........................................................................................9 ITI-8000 SERIES ADAPTERS INCLUDED IN THIS GUIDE ...............................10 SOFTWARE COVERED BY THIS GUIDE..........................................................11 DOCUMENTATION ORGANIZATION...............................................................12 ADAPTER CONFIG
Resumo do conteúdo contido na página número 7
Ethernet 10/100 Auto-Negotiation..........................................................43 Verifying the Installation........................................................................44 Diagnostic Testing..................................................................................45 Verify Connectivity by Monitoring Network Activity..............................47 SOFTWARE INSTALLATION .................................................................48 INSTALLATION FOR SUN™ SPARC™ S
Resumo do conteúdo contido na página número 8
END-USER LICENSE AGREEMENT FOR SOFTWARE........................................77 PRODUCT WARRANTY.........................................................................81 READER’S COMMENTS.................................................................................83 Page 8 of 83
Resumo do conteúdo contido na página número 9
________________________1 Introduction IntraServer’s ITI-8000 Series Ultra2/Ultra3 SCSI, Quad Fast Ethernet and ® Video adapters for CompactPCI combine state of the art Low Voltage Differential (LVD) Ultra2 and Ultra3 SCSI technology with multiport Fast Ethernet and Video. IntraServer ITI-8000 Series adapters provide maximum integration of the most commonly required server functions, leaving the ® maximum number of free CompactPCI slots available for your application. IntraServer provides state
Resumo do conteúdo contido na página número 10
ITI-8000 Series Adapters Included in This Guide This guide covers the installation and operation of IntraServer’s ITI-8000 ® Series CompactPCI Combination adapters as follows: IntraServer Description Part ® ITI-8241C-S IntraServer CompactPCI Combination Adapter with: Two Ultra2 SCSI ports, Four Fast Ethernet Ports and one Video Port. ® ITI-8240C-S IntraServer CompactPCI Combination Adapter with: Two Ultra2 SCSI ports and Four Fast Ethernet Ports. ® ITI-8200C-S IntraServer CompactPCI Adapter with
Resumo do conteúdo contido na página número 11
Software Covered by This Guide All IntraServer’s ITI-8000 Series CompactPCI adapters are supported by the Solaris operating system on SPARC™ based systems. Information regarding software installation is included in the software driver section of this guide. Support is currently available for the following operating systems: Operating System Intel SPARC™ 1 Sun Solaris Version 2.6 No Yes 1 Sun Solaris Version 7.0 No Yes 2 Sun Solaris Version 8.0 No Yes WindowsNT/Windows95/98 No N/A Linux No N/A N
Resumo do conteúdo contido na página número 12
Documentation Organization This manual is organized into the following sections: • Adapter Configuration and Installation • BIOS and Firmware Configuration • Testing the Installation • Software Driver Installation and Configuration Page 12 of 83
Resumo do conteúdo contido na página número 13
________________________2 Adapter Configuration ® IntraServer CompactPCI Combination adapters will have a different connector configuration depending on which variation you have purchased. This guide will cover the ITI-8241C-S, two Ultra2/LVD SCSI port, four Fast Ethernet and Video, fully configured module. For all other variations of the adapter, simply skip those sections that do not apply to your adapter. I/O Connectors SCSI ITI-8000 host adapters include an external SCSI Connector for each
Resumo do conteúdo contido na página número 14
handle is qfe0. See Figure 1 for location of the ports, and Appendix A for connector pin-out. 1 Note: Your ports will be named with the next four available qfe numbers if there are existing qfe ports in your system. Video A 15-pin “D” standard VGA connector is provided on the module handle. Plug your VGA monitor into this connector, and your system keyboard and mouse to the CPU keyboard and mouse port. Solaris will automatically recognize the ATI video subsystem under the m64 driver. Page 14 o
Resumo do conteúdo contido na página número 15
ITI-8241C-S Handle Connections Use the following diagram as a guide when connecting your external devices to IntraServer’s ITI-8241C-S adapter. Ethernet Port 0 [qfe0] Ethernet Port 1 [qfe1] Ethernet Port 2 [qfe2] Ethernet Port 3 [qfe3] Link/Activity Port 1 Link/Activity Port 0 Link/Activity Port 3 Link/Activity Port 2 SCSI Status Port A Left = LVD Center = TERM Right = Activity Ultra2 SCSI Port A Ultra2 SCSI Port B SCSI Status Port B Left = LVD Center = TERM Right = Activity VGA Video Connector
Resumo do conteúdo contido na página número 16
ITI-8241C-R Handle Connections Use the following diagram as a guide when connecting your external devices to IntraServer’s ITI-8241C-R rear I/O module. Ethernet Port 3 [qfe3] Ethernet Port 2 [qfe2] Ethernet Port 1 [qfe1] Ethernet Port 0 [qfe0] Link/Activity Port 1 Link/Activity Port 0 Link/Activity Port 3 Link/Activity Port 2 SCSI Status Port B Left = Activity Center = TERM Right = LVD Ultra2 SCSI Port B Ultra2 SCSI Port A SCSI Status Port A Left = Activity Center = TERM Right = LVD VGA Video Co
Resumo do conteúdo contido na página número 17
ITI-8241C-S Module Configuration The following diagram can be used to locate the major components and option jumpers on the ITI-8241C-S adapter. J 6,7,8,9 HDR 1,6,3,7 J 11 HDR 1002 J 10 HDR 5 HDR 4 Figure 3: ITI-8241C-S Configuration Jumper and Header Location Page 17 of 83
Resumo do conteúdo contido na página número 18
Header Number Function HDR 1 Bus A Internal Termination Invert HDR 3 Bus B Internal Termination Invert HDR 4 Video Disable HDR 5 Video Interrupt Disable HDR 6 Bus A External Termination Invert HDR 7 Bus B External Termination Invert HDR 1002 Hot Swap Register Disable J 6 Ethernet Port 0 Front/Rear Select J 7 Ethernet Port 1 Front/Rear Select J 8 Ethernet Port 2 Front/Rear Select J 9 Ethernet Port 3 Front/Rear Select J 11 Video Front/Rear J 10 Video Front/Rear Table 4: Configuration Headers and J
Resumo do conteúdo contido na página número 19
ITI-8241C-R Rear I/O Transition Module Figure 4: IntraServer ITI-8241C-R Rear I/O Transition Module Page 19 of 83
Resumo do conteúdo contido na página número 20
Installing the ITI-8241C-S Adapter The ITI-8241C-S Combination host adapter is plug and play compatible with Sun Solaris SPARC™ systems. All functions of the ITI-8241C-S adapter are accessible from the front of the adapter. With the addition of the optional ITI-8241C-R rear I/O module, all functions can also be brought to the rear of the system. If you plan on using the ITI-8241C-R rear I/O module, you must configure your ITI-8241C-S adapter to select rear or front output for the Video and Eth