Resumo do conteúdo contido na página número 1
Eiconcard C2x Family
for ISA-Compatible Bus
www.eicon.com
Resumo do conteúdo contido na página número 2
First Edition (July 2001) 203-225-01 Eicon, Eiconcard, and the Eicon logo are either trademarks or registered trademarks of Eicon Networks Corporation. Changes are periodically made to the information herein; these changes will be incorporated into new editions of the publication. Eicon Networks may make improvements and/or changes in the products and/or programs described in this publication at any time. Copyright © 1996-2001 Eicon Networks Corporation. All rights reserved, including those
Resumo do conteúdo contido na página número 3
Table of Contents Introduction ................................................................... 5 About this Manual....................................................................... 5 Installing the Eiconcard C2x.......................................... 6 Making an ISDN Connection......................................... 8 Termination ............................................................................... 11 Making a V.24 Connection .......................................... 13
Resumo do conteúdo contido na página número 4
www.eicon.com
Resumo do conteúdo contido na página número 5
Introduction The Eiconcard C2x is an ISA Plug-and-Play (PnP) card that offers X.25 connectivity through a V.24 serial port at speeds of up to 64 Kbps, and/or through an ISDN BRI port (Eiconcard C21) at speeds of up to 128 Kbps (over the “D” channel or the “B” channels). The Eiconcard C2x is typically used for stand-alone or remote LAN gateways. Note The Eiconcard C2x also supports protocols such as SDLC, PPP, and Frame Relay. All Eiconcards have been tested and found to comply with the El
Resumo do conteúdo contido na página número 6
Installing the Eiconcard C2x Follow the steps below to install the Eiconcard C2x. If you want the Eiconcard C2x to be available to multiple users on a LAN, install it in the PC that will function as a gateway for the LAN. 1 Prepare the PC Turn off the PC and disconnect its power cable. Remove the cover of the PC according to the instructions that came with it. 2 Install the Eiconcard C2x a) Drain static electricity from your body by touching the metal chassis (the unpainted metal at the
Resumo do conteúdo contido na página número 7
screw ISA Eiconcard ISA slot Figure 2. Inserting the Eiconcard C2x. e) Fasten the adapter with the screw (to ensure that the adapter is properly secured and grounded to the PC’s chassis). f) Replace the cover of your PC as described in your PC’s manual. g) Reconnect the power cable. Note Although the Eiconcard C2x can be installed in any available ISA expansion slot (unless the PC’s documentation specifies otherwise), it is recommended that you install the card in a 16-bit slot to take adv
Resumo do conteúdo contido na página número 8
Making an ISDN Connection Note Only the Eiconcard C21 supports ISDN connections. After you have installed your Eiconcard C21, connect your ISDN line. In Europe and most countries worldwide In Europe as well as most countries outside of North America and Japan, your Eiconcard C21 adapter can be connected directly to your ISDN line using the included cable. ISDN wall jack 1. Eiconcard C21 3. 2. Figure 3. Connecting the ISDN cable. 1 Take the cable included with the Eiconcard C21. 2 Plug one
Resumo do conteúdo contido na página número 9
Eiconcard C21 U-interface: If your Eiconcard C21 has a U-interface, the NT1 is integrated into the adapter, and you do not need a separate NT1. ISDN wall jack 1. Eiconcard C21 3. 2. Figure 4. Connecting the ISDN cable. 1 Take the cable included with the Eiconcard C21. 2 Plug the RJ-45 end into the Eiconcard C21. 3 Plug the RJ-11 end into the ISDN wall jack. Note In North America, many ISDN wall jacks (with a U-interface) are RJ-11. However, if your ISDN wall jack is RJ-45, you can still plug
Resumo do conteúdo contido na página número 10
Eiconcard C21 S/T-interface: If your Eiconcard C21 has an S/T-interface, you need a separate NT1. Note You can order an NT1 from Eicon Networks or from another supplier. Eiconcard C21 ISDN wall jack 2. 4. 3. 5. 6. 1. NT1 S/T jack U jack Figure 5. Connecting to an NT1. 1 Take the cable included with the Eiconcard C21. 2 Plug one end into the Eiconcard C21. 3 Plug the other end into the NT1’s S/T jack. 4 Take the cable included with the NT1. 5 Plug one end into the ISDN wall jack. 6 Plug the ot
Resumo do conteúdo contido na página número 11
Termination This section applies to S/T interface users in Australia and North America, and provides instructions to help set up termination scenarios. Termination requirements vary according to: the number of devices connected to the NT1; and the distance between the devices and the NT1. For users who require termination, the Eiconcard C21 S/T has been shipped with a separate terminating resistor. For information on how to install the terminating resistor, see “Installing a Terminating
Resumo do conteúdo contido na página número 12
Multiple ISDN Devices If the NT1 is connected to more than one ISDN device, follow the procedures below. 75 meters or more If the connection spans 75 meters (250 feet) or more, both end devices on the ISDN bus must be set to 100 ohm termination. If the Eiconcard is one of the end devices, connect the 100 ohm terminating resistor included with the ISDN cable. Consult the manuals provided with the other ISDN devices and NT1 for more details. Note Some NT1s do not support connections over 75
Resumo do conteúdo contido na página número 13
Making a V.24 Connection The Eiconcard C21 can make V.24 connections using standard V.24 cables. Connection Cables Required Part # Eiconcard C21 to V.24 DCE V.24 DCE Cable 300-007 Eiconcard C21 to V.24 DTE V.24 Null Modem Cable, or 300-022 V.24 Null Modem Cable (gender-changed) 300-048 Table 1. Standard Interface Cables Interface Specifications The standards compliant with the V.24 interface are listed in Table 2. Standard Compatibility CCITT V.24 Signaling CCITT V.28 Electrical CCITT X.21bi
Resumo do conteúdo contido na página número 14
The V.24 DCE Interface 1 14 PGND TXD A pin-out diagram for the V.24 RXD TCLK DCE interface is shown in RTS RCLK CTS Figure 6. The signal definitions TEST DSR and names are listed in Table 3. DTR SGND RLB DCD RI DTECLK TI 25 13 Figure 6. V.24 DCE Interface Pin # Signal Name Direction CCITT # 1 PGND Protective Ground Common 101 2 TXD Transmit Data Output 103 3 RXD Receive Data Input 104 4 RTS Request to Send Output 105 5 CTS Clear to Send Input 106 6 DSR Data Set Ready Input 107 7 SGND Signal G
Resumo do conteúdo contido na página número 15
LED Functionality Note The Eiconcard C20 only has the V.24 port, the Eiconcard C21 has both the ISDN BRI port and V.24 port.. ISDN (Eiconcard C21 only) D-channel Status The D-channel controls the link to your ISDN service provider. Off ..........The line is not active. The cable may not be connected. Blinking ..The line is active, but a link can’t be established. This may be a symptom of incorrect configuration. Steady....The ISDN line is active and operating normally. ISDN (Eiconcard C2
Resumo do conteúdo contido na página número 16
Technical Specifications Technical Data PCI bus compatible (32-bit slot) Eiconcard CPU/Memory/Flash # of HSI Ports #of ISDN BRI Ports Eiconcard C20 15.36 MHz Motorola 68302 1N/A 512 KB RAM / 512 KB Flash Eiconcard C21 15.36 MHz Motorola 68302 11 512 KB RAM / 512 KB Flash Hardware Installation Automatic configuration of interrupt request level setting and I/O address 8-bit I/O access External Interface Eiconcard External Interface Eiconcard C20 One DB-25 femaleport. Eiconcard C21 One DB-25
Resumo do conteúdo contido na página número 17
International Regulatory Information Regulatory Information for the USA: WARNING. Changes or modifications to this unit not expressly approved by Eicon Networks Corporation could void the user's authority to operate the equipment. Declaration of Conformity We: Eicon Networks Corporation 2155 Chenault Drive, Suite 503 Carrollton, Texas USA 75006 1-800-80-EICON (972) 417-5500 Fax: (972) 417-5610 Declare under our sole legal responsibility that the products listed below to which this declaratio
Resumo do conteúdo contido na página número 18
FCC Part 68 Notice This unit complies with Part 68 of the FCC rules. On the bottom of this equipment is a label that contains, among other information, the FCC registration number. If requested, this information must be provided to the telephone company. An FCC compliant telephone cord and modular plug is provided with this equipment, designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. This equipment cannot be used
Resumo do conteúdo contido na página número 19
Regulatory Information for Canada NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. Industry Canada does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must
Resumo do conteúdo contido na página número 20
Regulatory Information for Europe EU Declaration of Conformity EN: Eicon Networks Corporation declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive1999/5/EC. DE: Eicon Networks Corporation erklärt, daß diese Telekommunikations-endeinrichtung den grundlegenden Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG entspricht. DK: Eicon Networks Corporation erklærer, at dette udstyr er i overensstemmelse