Resumo do conteúdo contido na página número 1
SmartCell 6A000/ZX-250
Reference Manual
35 Industrial Way
Rochester, NH 03866-5005
USA
(603) 332-9400
Part # 04-0044-02 Rev. A
Order # 9032400
Resumo do conteúdo contido na página número 2
NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, BUT N
Resumo do conteúdo contido na página número 3
REVISION HISTORY Document Name: SmartCell 6A000/ZX-250 Reference Manual Document Order Number: Order # 9032400 Document Part Number: Part # 04-0044-02 Rev. A Author: Bruce Jordan Editor: Carre Gibson Date Revision Description October 1997 A Initial release SmartCell 6A000/ZX-250 Reference Manual iii
Resumo do conteúdo contido na página número 4
iv SmartCell 6A000/ZX-250 Reference Manual
Resumo do conteúdo contido na página número 5
TABLE OF CONTENTS 1 Introduction 1-1 Audience and Scope 1-1 Definitions 1-1 Content 1-1 Sections 1-2 Conventions 1-2 Abbreviations 1-3 Help Options 1-4 Other Reference Options 1-4 Switch Attribute 1-5 List of Commands and Possible Switch Attributes 1-9 2 Console Commands 2-1 Alarm 2-1 AlarmConfig 2-6 AlarmVerbose 2-9 BUSClient 2-10 BUSELAN 2-12 BUSLECStat 2-16 BUSStat 2-18 CACParams 2-20 CACStat 2-22 Client 2-24 ClientARP 2-28 ClientStat 2-30 ClientVC 2-35 Community 2-37 Config 2-39 ELAN 2-41 Ex
Resumo do conteúdo contido na página número 6
Table of Contents IPATMStat 2-64 LANEClient 2-66 LECS 2-68 LECSAddress 2-70 LECSELAN 2-72 LECSELANLEC 2-75 LECSStat 2-78 LECSTLVParam 2-81 LECSTLVSet 2-83 LECSVCC 2-88 LES 2-90 LESARP 2-91 LESClient 2-92 LESELAN 2-94 LESLECStat 2-98 LESStat 2-100 Log 2-103 LogAlarmMask 2-104 LogBuffer 2-106 LogBufferSize 2-108 LogPrint 2-109 LogTrace 2-111 MyNMAddr 2-124 NetPrefix 2-126 Passwd 2-128 Ping 2-129 PortAutoDetect 2-130 PortConfig 2-132 PortMode 2-137 PortStat 2-140 PortTrafficCongestion 2-143 Privi
Resumo do conteúdo contido na página número 7
Table of Contents Switch 2-182 SwitchConfig 2-184 SwitchName 2-188 SwitchTrafficCongestion 2-189 TrafficDescriptor 2-197 TrustedNMS 2-199 UNIRoute 2-201 VCCMask 2-204 WellKnownAddress 2-206 3 Boot Load Commands 3-1 Accessing the Boot Load Commands 3-2 chpi 3-3 clfs 3-4 dcfg 3-5 df 3-6 go 3-7 he 3-8 ponf 3-9 A Acronyms A-1 B Cause Codes B-1 C Technical Support C-1 Telephone Assistance C-1 FAX Service C-1 Electronic Services C-1 Placing A Support Call C-1 Hardware Warranty C-2 Software Warranty
Resumo do conteúdo contido na página número 8
Table of Contents viii SmartCell 6A000/ZX-250 Reference Manual
Resumo do conteúdo contido na página número 9
LIST OF TABLES 1-1 List of Operators 1-5 1-2 Operator Table Explanation 1-6 1-3 Parameter Table Explanation 1-7 1-4 Description Table Explanation 1-8 1-5 Description Table Example 1-8 2-1 Filter Flags 2-113 2-2 Software Modules for LogTrace 2-116 2-3 Software Submodules for LogTrace 2-117 2-4 Traffic Descriptor Defining Entry Combinations 2-194 B-1 Cause code values and meanings B-1 SmartCell 6A000/ZX-250 Reference Manual ix
Resumo do conteúdo contido na página número 10
List of Tables x SmartCell 6A000/ZX-250 Reference Manual
Resumo do conteúdo contido na página número 11
1 INTRODUCTION This reference manual describes the console commands for the SmartCell 6A000 and SmartCell ZX-250 ATM switches. The two switches share a common console interface and are referred to in this manual as the SmartCell 6A000/ZX-250. Audience and Scope The manual is intended for network administrators and others responsible for maintaining the SmartCell 6A000/ZX-250. You do not need to read the manual from start to finish. You can use it to study the console commands you use. Defini
Resumo do conteúdo contido na página número 12
Introduction Sections Read "Switch Attribute" for an example and definition of the various sections under each switch attribute as well as a description of how the manual is organized. Each section begins with a switch attribute heading (for example, "PVCByID"). Then come the details of relevant operators, parameters, and commands. Most sections have two parameter tables—one for input and another for output. The tables contain the parameter names, descriptions, and definitions of their va
Resumo do conteúdo contido na página número 13
Introduction IP NetMask : 255.255.255.0 IP/ATM Client 3 ============================================================================== Client State : Operational Client Address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:00:5A:01:01:7C:00 Server : is local Server Connection : Established MTU : 9180 IP Address : 90.1.1.124 Abbreviations Pay close attention to how switch attributes appear in each section heading. Switch attributes are not ca
Resumo do conteúdo contido na página número 14
Introduction Help Options If you want information on a specific command, type ? or help before typing the command and you will get a brief description of the command and all its input parameters. If you want information about a specific input parameter while executing a command, type ? or help after it appears on the console and it will give you details relating to that parameter. For example, switch_prompt # ? add lecselan Create/Add ELAN for LECS(LECSELAN) ===============================
Resumo do conteúdo contido na página número 15
Introduction Switch Attribute This section—immediately below the heading—gives a brief description of what the switch attribute does. A detailed description of each command is available under "Descriptions." SERVER SVC XX "X" under any of these headings indicates the switch attribute is applicable to that software type. Parameters Operators make the switch attribute work. Operators pertaining to each switch attribute are listed immediately below the "Operators" heading. The command is the sw
Resumo do conteúdo contido na página número 16
Introduction Table 1-1 List of Operators (Continued) Operator Action passwd Changes passwords reboot Reboots the switch restart Restarts LANE and IP-ATM clients restore Restores switch configuration setup Sets up switch show (display) Shows properties of an object OPERATOR ACTION shutdown Shuts down switch start Starts server stop Stops server update Upgrades firmware Operators Table 1-2 Operator Table Explanation Parameter Description Value/Field Size Default [Input or Output Field]
Resumo do conteúdo contido na página número 17
Introduction Only one parameter table in a switch attribute section means either that switch attribute uses only input parameters or that the output parameters are identical to the input parameters. The heading of the table indicates which is the case. If the table heading says Input Parameter or Output Parameter, only input or output parameters apply to this switch attribute. However, if the table heading says Parameter, the table contains both input and output parameters, and their field
Resumo do conteúdo contido na página número 18
Introduction Descriptions Table 1-4 Description Table Explanation Operator Parameters/Permissions Description console [InputParameter] This section provides detailed descriptions of the command command (operator and switch attribute) and discusses what the (Privilege level this console command command does and how and when it is used. Other relevant allows:) information appears here. Administrator or All The following is an example of a description section. It is located und
Resumo do conteúdo contido na página número 19
Introduction switch_prompt # show buselan ELANNumber : 103 ELAN : elan103 ELAN Number : 103 ELAN Name : elan103 ATM Address :39:00:00:00:00:00:00:00:20:D4:14:15:00:00:20:D4:14:15:66:02 Max Frame Size : 4544 Connection Method : PVC Distribute VPI/VCI: 0/50 LAN Type : 802.5 Multipoint : YES switch_prompt # List of Commands and Possible Switch Attributes add (create) AlarmConfig BUSELAN Community ELAN IISPRoute IPATMClient IPATMPVC LANEClient LECSAddress LE
Resumo do conteúdo contido na página número 20
Introduction modify (set) AlarmConfig AlarmVerbose BUSELAN CACParams ILMIAdminStatus IPAddress IPATMClient LANEClient LECSAddress LECSELAN LECSELANLEC LECSTLVSET LESELAN LogAlarmMask LogBuffer LogPrint LogTrace MyNMAddr NetPrefix PortAutoDetect PortConifg PortMode PortTrafficCongestion Prompt Rows SigConfig SwitchConfig SwitchName SwitchTrafficCongestion TrustedNMS VCMask 1-10 SmartCell 6A000/ZX-250 Reference Manual