Resumo do conteúdo contido na página número 1
PRIMERGY RX200 S5 Server
Options Guide
Edition April 2009
Resumo do conteúdo contido na página número 2
Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which compl
Resumo do conteúdo contido na página número 3
Contents 1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 5 1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 5 1.3 Expansions and conversions . . . . . . . . . . . . . . . . . . 7 1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . . 9 2 Procedure . . . . . . .
Resumo do conteúdo contido na página número 4
Contents 7.1 Installing a SATA DVD drive . . . . . . . . . . . . . . . . . . . 38 8 HDD modules . . . . . . . . . . . . . . . . . . . . . . . . . . 41 9 Expansion cards and iBBU . . . . . . . . . . . . . . . . . . . 47 9.1 Installing an expansion card in riser cards . . . . . . . . . . 47 9.2 Installing a modular RAID controller . . . . . . . . . . . . . . 51 9.3 Installing an iBBU . . . . . . . . . .
Resumo do conteúdo contido na página número 5
1 Preface The PRIMERGY RX200 S5 server is an Intel-based server for mid-size networks and large companies. The server is suitable for use as a file server and also as an application, information or Internet server. Thanks to its highly developed hardware and software components, the PRIMERGY RX200 S5 server offers a high level of data security and availability. These components include hot-plug hard disk drive modules, redundant system fans and power supply units, the Server Management Serv
Resumo do conteúdo contido na página número 6
Documentation overview Preface – “Warranty” manual – “PRIMERGY ServerView Suite Local Service Concept - LSC” manual – “Returning used devices” manual – “Helpdesk” leaflet – Technical manual for the system board D2786 – “PRIMERGY RX200 S5 Server Operating Manual” – "D2786 BIOS Setup Utility for RX200 S5" manual I PRIMERGY manuals are available in PDF format on the PRIMERGY ServerView Suite DVD 2. The PRIMERGY ServerView Suite DVD 2 is part of the PRIMERGY ServerView Suite supplied with every se
Resumo do conteúdo contido na página número 7
Preface Expansions and conversions 1.3 Expansions and conversions Second processor The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency as the first. Main memory expansion The system board supports up to 96 GB of main memory. 6 slots (2 banks with 3 channels each) are provided for each CPU for the main memory. Accessible drive In the version with a maximum of six HDD
Resumo do conteúdo contido na página número 8
Expansions and conversions Preface TPM A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the Fujitsu Technology Solutions BIOS manual). V CAUTION! – When using the TPM, note the program descriptions provided by the third party ma
Resumo do conteúdo contido na página número 9
Preface Notational conventions 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands or menu items. “Quotation marks” indicate names of chapters and terms that are being emphasized. Ê describes activities that must be performed in the order shown. V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. I in
Resumo do conteúdo contido na página número 10
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: W:\Anwendungsdaten\FCT\tim_local\work\PICHOL\OBJ_DOKU-4098-001.fm
Resumo do conteúdo contido na página número 11
2Procedure V CAUTION! ● The actions described in this manual should only be performed by technical specialists. ● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter- ference with the system will void the warranty and exempt the manufacturer from all liability. ● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards,
Resumo do conteúdo contido na página número 12
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: W:\Anwendungsdaten\FCT\tim_local\work\PICHOL\OBJ_DOKU-4099-001.fm
Resumo do conteúdo contido na página número 13
3 Safety instructions I The following safety instructions are also provided in the manual “Safety notes and other important information”. This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! ● The actions described in this manual should only be performed by technical specialists. ● Repairs to the device that
Resumo do conteúdo contido na página número 14
Safety instructions Before starting up V CAUTION! ● During installation and before operating the device, observe the instructions on environmental conditions for your device. ● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. ● Transport
Resumo do conteúdo contido na página número 15
Safety instructions V CAUTION! ● Ensure that the power sockets on the device and the grounded shock- proof sockets are freely accessible. ● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the grounded shockproof sockets. ● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of lo
Resumo do conteúdo contido na página número 16
Safety instructions V CAUTION! ● Proper operation of the system (in accordance with IEC 60950-1/ EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). ● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other ex
Resumo do conteúdo contido na página número 17
Safety instructions Working with CDs/DVDs and CD/DVD drives When working with devices with CD/DVD drives, these instructions must be followed. V CAUTION! ● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipment damage and injury. ● Check each CD/DVD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance. D
Resumo do conteúdo contido na página número 18
Safety instructions Modules with electrostatic-sensitive components Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: ● Remove the power plug before installing or removing components containing ESDs. ● You must always discharge yourself of static charges (e.g. by touching a grounded object) before work
Resumo do conteúdo contido na página número 19
4 Preparation V CAUTION! Follow the safety instructions in the chapter “Safety instructions” on page 13. 4.1 Pulling out/removing the server Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press the on/off button. Ê Pull all power connectors out of the power outlets. Ê Loosen the knurled screws on the sides and pull the server carefully out of the rack as far as it will go. I If the server is not easily accessible on
Resumo do conteúdo contido na página número 20
Opening the server Preparation 4.2 Opening the server You must remove the fan cover before removing the housing cover. Removing the fan cover 1 2 1 Figure 2: Opening the fan cover Ê Push the two green buttons (1) in the direction of the arrow and lift the fan cover upwards to remove it (2). Removing the housing cover Figure 3: Removing the housing cover Ê Use the two green locking levers (see circles) to unlock the housing cover. 20 Options Guide RX200 S5 © cognitas. Gesellschft für Technik-Do