Resumo do conteúdo contido na página número 1
Baby Monitor
Secure 300
User Guide
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS WARNINGS AND SAFETY INFORMATION 1 GETTING STARTED 3 YOUR BABY MONITOR 6 BASIC OPERATION 10 TROUBLESHOOTING 15 PRODUCT SPECIFICATIONS 16 GUARANTEE 17
Resumo do conteúdo contido na página número 3
WARNINGS AND SAFETY INFORMATION 1 Do not place the cord in a high "wear and tear" location. IMPORTANT Never use a frayed or compromised cord. Please read this user guide thoroughly before use. Never use or place your Parent or Baby units in or near Your ORICOM Baby Monitor is designed to be an aid and moisture or water (e.g. near bath or pool). Immersing in should not be used as a substitute for responsible and water can cause electric shock and even death. proper adult supervision of a chi
Resumo do conteúdo contido na página número 4
2 WARNINGS AND SAFETY INFORMATION • The Ni-MH batteries supplied with this product may be Battery requirements able to be recycled once they are unable to recharge during normal operation. Always observe your local Each parent unit requires two rechargeable Ni-MH Council /State regulations regarding the disposal of batteries, size AA 1.2V 1300mAh. your packaging materials, exhausted batteries, and old • Do not dispose of the batteries in a fi re, as they can equipment. explode. • Always r
Resumo do conteúdo contido na página número 5
GETTING STARTED 3 Thank you for choosing this monitor from Oricom. Installation and Charger Your Secure 300 Baby Monitor offers the best Digital Technology. For the Parent Unit 1 Remove the battery cover on the back of the Parent INTERFERENCE Unit by pressing and FREE FREQUENCY sliding it down. Insert the DECT (Digital Enhanced Cordless Telecommunications) is the rechargeable batteries as most widely used worldwide digital cordless technology, offering marked on the unit and amazingly c
Resumo do conteúdo contido na página número 6
4 GETTING STARTED 4 Press [ ] to turn the Parent Unit on. 4 Press [ ] to turn on the Baby Unit. • Before fi rst use, or if it has been out of use for a long • The Baby Unit should be placed about 1 metre time, the Parent Unit will need to be charged for 14 to 1.5 metres away from the baby’s cot on a flat hours. During this time, the Parent Unit will operate surface. Never place the Baby Unit inside the cot, from the Charger pod when switched on. Note that the bed or playpen. Make sure the
Resumo do conteúdo contido na página número 7
Ø 4.00 GETTING STARTED 5 1. Insert screws into the wall through the wall mount. Wall mounting the Baby Unit The recommended mounting screw size is diameter Use the following wall mount diagram to locate and install 3mm and length 20mm,the diameter of the screw the mounting pins/screws if you prefer to wall mount your head and the screw should not be greater than base unit. The dimensions are shown in millimeters (mm). 7.55mm and 4mm respectively. 58.00 2. Put the base unit down into wall m
Resumo do conteúdo contido na página número 8
6 YOUR BABY MONITOR Baby unit (Sender) Night light Up/Register Press to switch night light on Increase speaker volume. or off. Use to enter registration mode. Down/Default Brightness Decrease speaker volume. Press to adjust the night light Used to restore original settings. brightness (once night light is switched on). There are three levels. Page Play/Stop Press to page the Parent unit Press to play lullaby, press – useful for fi nding when it is again to stop. misplaced. Power on/off Lullab
Resumo do conteúdo contido na página número 9
YOUR BABY MONITOR 7 Back of Baby unit Underside Power socket For connection to mains power. Battery lock Child tamper proof lock for the battery compartment.
Resumo do conteúdo contido na página número 10
8 YOUR BABY MONITOR Parent unit From the Parent unit you can listen to your baby and operate the Baby unit by remote control. LED Link indicator Green On – Linked to Baby unit Green fl ashing – Not linked to Baby unit – fi rst 30 seconds Red Flashing – Not linked to Baby unit – for longer than 30 seconds. Talk (on side of unit) Sensitivity / Volume level LEDs Press to talk to your baby. During use, lights indicate: – Sensitivity level – Volume level Lullaby LEDs Green on - When the selected Ba
Resumo do conteúdo contido na página número 11
YOUR BABY MONITOR 9 Parent unit charger Front Back Charging light Power socket Indicates Parent unit is charging. For connection to mains power.
Resumo do conteúdo contido na página número 12
10 BASIC OPERATION Once you have set up your Baby Monitor, you will be able switched on and will search for and link itself to the to hear the sounds in your baby’s room through the Parent Baby unit. Unit. And also see the green and red sensor lights around • To switch off, press [ ] key until all lights turn off. the top of the Parent Unit rise and fall with the sound levels. Note: Changing Baby unit from battery to If the connection between the Parent and Baby Units is broken at any time
Resumo do conteúdo contido na página número 13
BASIC OPERATION 11 • If the volume of the Parent Unit is turned off, an alert high sensitivity. When only one green light is lit, it will sound when the audio picked up reaches the represents low sensitivity. second red led. Level 1 1 light on (voice activated) Note: Level 2 2 lights on (voice activated) Do not position the baby unit and the parent unit close Level 3 3 lights on (voice activated) to each other or in the same room as feedback may be Level 4 4 lights on (voice activated) gen
Resumo do conteúdo contido na página número 14
12 BASIC OPERATION • Press [Page] key on the Baby Unit. The paging alert Talk Back will sound. You can use the talk back feature to talk to your baby. • To stop the Page alert, press any button on the Parent Unit, or press [Page] key again on the Baby Unit. • Press and hold [Talk] key on the Parent unit to speak to baby. The green link lights on both Units fl ash. Note: If no button is pressed, the paging tone will stop after 2 • Talk into parent unit's microphone. minutes. • Release [Talk]
Resumo do conteúdo contido na página número 15
BASIC OPERATION 13 Out of Range Lullaby When the baby and parent units have no link with each other The Baby unit plays lullabies to gently soothe your baby (eg. Out of range, parent unit or Baby unit is not powered back to sleep. Each lullaby is played repeatedly for 15 on), the green Link light fl ashes. If there is no link for more minutes. Select one of the three melodies or select Play All than 30 seconds, the red Link Light fl ashes and the green for a medley of all 3 lullabies for 15
Resumo do conteúdo contido na página número 16
14 BASIC OPERATION Note: Restore to Default Setting Low battery alert can be suppresed by pressing any button. You can return the baby and parent units to factory default settings. The Parent and Baby units are reset individually. Charging the Battery • Press [ ] key to switch the unit off. Place the parent unit on its charger pod to charge the • Press and hold [ ] key again to switch the unit on. battery. When charging, the red light on the charger will • While the unit is switching on,
Resumo do conteúdo contido na página número 17
TROUBLESHOOTING 15 Problem Possible cause(s) The red power lights do not turn on when you 1. Check if the units are properly connected to the power supply. plug in the power. 2. Check if the power is turned on. If not, Press [ ] to turn on the power. 1. You may have moved out of range. Move closer to the Baby Unit and The green Link light on the Parent Unit is wait 5 seconds for the Link to establish. fl ashing and cannot hear the sounds from 2. You may need to re −establish the Link betwee
Resumo do conteúdo contido na página número 18
16 PRODUCT SPECIFICATIONS Feature Specifi cations Operating Frequency 1.8 GHz Up to 300 m under optimum conditions. The range is reduced in Range buildings (up to 50 m) as a result of walls, doors etc. Input: 100 - 240 V 50 - 60 Hz AC Power supply (parent unit / baby unit) Output: 7.5 V , 500 mA, DC Non rechargeable batteries (baby unit) Type: AA, 1.5 V Alkaline (not included in the package contents) Transmitting power Average: 10 mW Maximum: 250 mW Re-chargeable batteries (parent unit) Type: A
Resumo do conteúdo contido na página número 19
GUARANTEE 17 Warranty (Australia) (a) Warranty Oricom International Pty Ltd (Oricom) warrants that (v) Modification to the product or services carried out to the the product is free from defects in materials and workmanship product by anyone other than Oricom or on Oricom's for a period of 12 months effective from the date of purchase. behalf. This warranty in no way affects your statutory warranty under Oricom will not be liable for consequential losses including loss of the Trade Practices
Resumo do conteúdo contido na página número 20
Australia Customer Support Oricom International Pty Ltd Email: support@oricom.com.au Locked Bag 658 Web: www.oricom.com.au South Windsor, NSW 2756 Phone: 1300 889 785 Fax: (02) 4574 8898