Resumo do conteúdo contido na página número 1
INSTALLATION
®
Spectra IV Series
®
Spectra IV SE Series
Surface Mount Back Box
C3416M-B (11/06)
Resumo do conteúdo contido na página número 2
Installation 1 3 2 2 C3416M-B (11/06)
Resumo do conteúdo contido na página número 3
1. Using the back box as a template, mark the fastener positions on the mounting surface. 2. Prepare the mounting surface. Pull power and video wire/cable for the dome system. Refer to Table A, Table B, and Table C for wiring distances. 3. Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. Pull wiring into the back box. . Table A. Video Coaxial Cable Table B. 24 VAC/24VDC Wiring Distances Requirements The following are the recommended
Resumo do conteúdo contido na página número 4
4 1 2 3 5 ALARMS 4 5 6 7 GND NO AUX1 COM NC AUX2 GND VIDEO PWR- GND PWR+ RX- RX+ TX- TX+ UTP+ UTP- 4 C3416M-B (11/06)
Resumo do conteúdo contido na página número 5
4. Attach the back box to the mounting surface. WARNING: An electrical short in the back box may occur if the metal BNC connector is not completely covered by the protective boot. 5. Connect wiring to the circuit board inside the back box. When finished, close the door to the back box and turn on the power. The green LED will light. NOTES: • Aux 1: Maximum 2 A at low voltage (<40 V) Aux 2: Maximum 30 mA at 32 VDC � If you are using both unshielded twisted pair (UTP) wiring and a translator bo
Resumo do conteúdo contido na página número 6
6 8 SWITCH 1 AND 2 9 7 6 C3416M-B (11/06)
Resumo do conteúdo contido na página número 7
6. Attach the back box leash to the lower dome by sliding the leash through the tab of the lower dome until it snaps into place. 7. Configure DIP switches SW1 and SW2 located on the top of the dome drive. For DIP switch settings, refer to the labels located on the top of the dome drive or to the Switch Settings section. ® NOTE: When connecting more than one Spectra dome to a single controller, terminate the unit farthest from the controller. To terminate the dome drive set the SW2-10 switch t
Resumo do conteúdo contido na página número 8
Troubleshooting If your dome does not power up properly after installation, use the following steps. 1. Check the fuse on the circuit board inside the back box for continuity. Replace the fuse if needed. 2. Check the wiring with a volt meter to ensure proper voltage is being received into the back box. If your dome powers up correctly, but you do not have accurate control, use the following steps. 1. Check the signal with a volt meter or an oscilloscope. NOTE: This step will not apply if you are
Resumo do conteúdo contido na página número 9
Switch Settings WARNING: If you are using D-type or P-type control, your system may not operate if the baud rate and address switches are not set correctly. The switches are set at the factory at the defaults for D-type control (2400 baud and address 1). Table E. Switch Settings for SW2 Special Systems Switch Number 123456789 10 AD-32 Preset System ON CM9502 Setting ON Vicon Not currently available; SW2-3 is reserved for future use. Serial Port Settings Switch Number 123456789 10 RS422 OFF O
Resumo do conteúdo contido na página número 10
Table F. Switch Settings for SW1, P-Type Control NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF. For D-type control systems, refer to Table G. SWITCH SETTING SWITCH SETTING SPECTRA SPECTRA ADDRESS ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 1 OFF OFF OFF OFF OFF 17 OFF OFF OFF OFF ON 2 ON OFF OFF OFF OFF 18 ON OFF OFF OFF ON 3 OFF ON OFF OFF OFF 19 OFF ON OFF OFF ON 4 ON ON OFF OFF OFF 20 ON ON OFF OFF ON 5 OFF OFF ON OFF OFF 21 OFF OFF ON OFF ON 6
Resumo do conteúdo contido na página número 11
SWITCH SETTING SWITCH SETTING SPECTRA SPECTRA ADDRESS ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 31 ON ON ON ON ON OFF OFF OFF 71 ON ON ON OFF OFF OFF ON OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 72 OFF OFF OFF ON OFF OFF ON OFF 33 ON OFF OFF OFF OFF ON OFF OFF 73 ON OFF OFF ON OFF OFF ON OFF 34 OFF ON OFF OFF OFF ON OFF OFF 74 OFF ON OFF ON OFF OFF ON OFF 35 ON ON OFF OFF OFF ON OFF OFF 75 ON ON OFF ON OFF OFF ON OFF 36 OFF OFF ON OFF OFF
Resumo do conteúdo contido na página número 12
SWITCH SETTING SWITCH SETTING SPECTRA SPECTRA ADDRESS ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 111 ONONONON OFF ON ON OFF 151 ON ON ON OFF ON OFF OFF ON 112 OFF OFF OFF OFF ON ON ON OFF 152 OFF OFF OFF ON ON OFF OFF ON 113 ON OFF OFF OFF ON ON ON OFF 153 ONOFF OFF ON ONOFF OFF ON 114 OFF ON OFF OFF ON ON ON OFF 154 OFF ON OFF ON ON OFF OFF ON 115 ONON OFF OFF ONONON OFF 155 ON ON OFF ON ON OFF OFF ON 116 OFF OFF ON OFF ON ON ON OFF 1
Resumo do conteúdo contido na página número 13
SWITCH SETTING SWITCH SETTING SPECTRA SPECTRA ADDRESS ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 191 ON ON ON ON ON ON OFF ON 223 ON ON ON ON ON OFF ON ON 192 OFF OFF OFF OFF OFF OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 193 ON OFF OFF OFF OFF OFF ON ON 225 ON OFF OFF OFF OFF ON ON ON 194 OFF ON OFF OFF OFF OFF ON ON 226 OFF ON OFF OFF OFF ON ON ON 195 ON ON OFF OFF OFF OFF ON ON 227 ON ON OFF OFF OFF ON ON ON 196 OFF OFF ON OFF OFF O
Resumo do conteúdo contido na página número 14
Specifications GENERAL ELECTRICAL (Dome Drive Only) Construction Input Voltage 18-32 VAC; 24 VAC nominal Back Box Plastic 22-27 VDC; 24 VDC nominal Dome Drive Aluminum, thermoplastic Input Power Lower Dome Acrylic 24 VAC 23 VA nominal (indoor, without heater) Cable Entry (Back Box) 0.75-inch conduit fitting 24 VDC 0.7 A nominal (indoor, without heater) Pan Movement 360° continuous pan rotation Fuse 1.25 A Vertical Tilt Unobstructed +2° to -92° Auxiliary Outputs 2 (Spectra IV SE only) Manual Pan/
Resumo do conteúdo contido na página número 15
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective If a warranty repair is required, the Dealer must contact Pelco at in material or workmanship for a period of one year after the date of (800)þ289-9100 or (559) 292-1981 to obtain a Repair Authorization number shipment. (RA), and provide the following information: Exceptions to this warranty are as noted below: 1. Model and serial number 2. Date of shipment, P.O. number
Resumo do conteúdo contido na página número 16
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO9001 Australia | Canada | Finland | France | Italy | Russia | Singapore | Spain | Sweden | The Netherlands | United Arab Emirates | United Kingdom | United States