Resumo do conteúdo contido na página número 1
INSTALLATION/OPERATION
IRD/ERD2000 Series
Receiver
®
C1506M-A (8/02)
Resumo do conteúdo contido na página número 2
2 C1506M-A (8/02)
Resumo do conteúdo contido na página número 3
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ..................................................................................... 4 DESCRIPTION ..................................................................................................................................... 5 MODELS .................................................................................................................................... 5 MOUNTING .........................................................
Resumo do conteúdo contido na página número 4
IMPORTANT SAFEGUARDS AND WARNINGS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8. Use only with the cart, sta
Resumo do conteúdo contido na página número 5
DESCRIPTION The IRD/ERD2000 Series Receiver operates Pelco’s fixed speed pan/tilts and domes. ® The receiver works with standard and extended Coaxitron controllers, including the CM6700/ 7500/8500/9500, KBD9000, MPT9000/9008/9500, and MX4000. With Coaxitron control, pan/tilt and lens control signals are transmitted over the video coaxial cable. The control data is superim- posed on the vertical blanking interval of the video signal. Standard features include pan/tilt control (including auto and
Resumo do conteúdo contido na página número 6
ERD2200 WIRING POWER P/T GROUND TERMINALS STUD MAIN FUSE POWER SELECTOR SWITCH POWER TERMINALS (INSIDE) GROUND ENCLOSURE STUD FUSE Figure 2. ERD2200 Receiver Figure 3. ERD2200 Power Connections 1. Fuses are installed for 115 VAC operation. For 230 Input Power Enclosure Main VAC operation, install the appropriate fuses 115 VAC 4A .5A (supplied). Refer to Figure 2. 230 VAC 2A .25A 2. Set the power selector switch to either 115V or 230V to match your input power. Refer to Figure 2. 3. Loosen th
Resumo do conteúdo contido na página número 7
Rear View of Receiver DEFAULT SETTING 24V 115/230V ~ ~ FROM 50/60HZ 50/60HZ FACTORY 115/230V A A A A P/T C C C C 24V 50/60HZ POWER SELECT ~ ERD OPTION INPUT POWER Front View of Receiver VIDEO CLASS 2 WIRING PWR CX IN OUT ERD OPTIONS 115/230V~ 50/60Hz .60 / .27 AMPS IRD 24V~ C C I F Z C C N N 24V ,1A ~ 50/60Hz 5V TLC OC 1.35 AMPS CAM PWR PAN/TILT LENS AUX1 AUX2 Figure 4. ERD Wiring and Switch Setting 8. Set the P/T SELECT switch on the rear of the receiver according to the pan/tilt
Resumo do conteúdo contido na página número 8
IRD2024 WIRING Rear View of Receiver 24V 115/230V ~ ~ 50/60HZ 50/60HZ A A A A P/T C C C C 24V 50/60HZ POWER SELECT ~ ERD OPTION INPUT POWER Front View of Receiver VIDEO CLASS 2 WIRING PWR CX IN OUT ERD OPTIONS 115/230V~ 50/60Hz .60 / .27 AMPS C C IRD 24V~ I F Z C C N N 24V ,1A ~ 50/60Hz 5V OC TLC 1.35 AMPS CAM PWR PAN/TILT LENS AUX1 AUX2 Figure 5. IRD Wiring and Switch Setting 1. Connect power to the 24 VAC INPUT connector on the rear of the receiver. The receiver’s power requireme
Resumo do conteúdo contido na página número 9
OPERATION When power is applied to the receiver, the green PWR LED on the receiver lights. Whenever the receiver gets a valid Coaxitron control signal, the green CX LED blinks. RANDOM/AUTO SCANNING Operation of random and auto scanning depends on whether your transmitter/controller is communicating with the IRD2000/ERD2200 in standard or extended Coaxitron mode. Standard Coaxitron Press the Pan Auto (or Autoscan) key to begin random scanning. In random scan operation the pan/ tilt travels betwee
Resumo do conteúdo contido na página número 10
FUSE REPLACEMENT CAUTION: These service instructions are for use by qualified service personnel only. To reduce the risk of electrical shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. IRD2024 Lens/Auxiliary Fuse A 500 mA fuse protects the LENS and AUX 1 outputs. Remove the cover of the receiver to check the fuse. ERD2200 Main Fuse The main fuse protects the pan/tilt output when 24 VAC pan/tilt operation is selected.
Resumo do conteúdo contido na página número 11
TROUBLESHOOTING Check the wiring connections. If the CX LED does not blink when commands are sent to the receiver, make sure the controller is working properly. Also check the video coaxial cable between the controller and the VIDEO OUT connection on the receiver. An LRD41TLC Test Local Control Module is available from Pelco to test or troubleshoot your receiver, pan/tilt, and lens functions directly from the receiver. This lightweight, hand-held keypad tests the up, down, left, and right functi
Resumo do conteúdo contido na página número 12
WIRING TABLES Table A. 24 VAC Wiring Distances Table The following are the recommended maximum wire distances (transformer to load) for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Distances are calculated in feet; values in parentheses are meters. Wire Gauge 20 18 16 14 12 10 10 283 (86) 451 (137) 716 (218) 1,142 (348) 1,811(551) 2,880 (877) 20 141 (42) 225 (68) 358 (109) 571 (174) 9
Resumo do conteúdo contido na página número 13
SPECIFICATIONS ERD2200 IRD2024 Electrical Electrical Input Voltage: 115/230 VAC, 50/60 Hz Input Voltage: 24 VAC, 50/60 Hz Output Voltage Output Voltage Camera: 24 VAC (or 115/230 VAC if using Camera: 24 VAC enclosure power) Lens: 8 VDC Lens: 8 VDC Power Consumption Pan/Tilt: 24/115/230 VAC Receiver: 45 VA maximum Enclosure: 115/230 VAC Fuses Power Consumption Lens/Aux 1: .5A Receiver: 90 VA maximum, including 48 VA Video Input/ maximum at 24 VAC for pan/tilt and Output: 75 ohms camera (5 VA maxi
Resumo do conteúdo contido na página número 14
REGULATORY NOTICES NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guaran
Resumo do conteúdo contido na página número 15
WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600 Series); two years on all other cameras. ® • Three years on Genex Series (multiplexers, server, and keyboard). •Two years on all standard motorized or fixed focal length
Resumo do conteúdo contido na página número 16
® World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada