Central Processing Unit WJ-MPU955A
FAN ALARM
HDD
OPERATE ACTIVE
Central Processing Unit
Operating Instructions
Model No. WJ-MPU955A
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
No model number suffix is shown in this manual.
Resumo do conteúdo contido na página número 2
We declare under our sole responsibility that the product to which this Wij verklaren als enige aansprakelijke, dat het product waarop deze declaration relates is in conformity with the standards or other normative verklaring betrekking heeft, voldoet aan de volgende normen of andere documents following the provisions of Directives EEC/73/23 and normatieve documenten, overeenkomstig de bepalingen van Richtlijnen EEC/89/336. 73/23/EEC en 89/336/EEC. Vi erklærer os eneansvarlige for, at dette prod
Resumo do conteúdo contido na página número 3
For Canada This Class A digital apparatus complies with Canadian ICES-003. For U.S.A NOTE: This equipment has been tested and found to com- ply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pro- vide reasonable protection against harmful interference when the equipment is operated in a commercial environ- ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
Resumo do conteúdo contido na página número 4
Important Safety Instructions 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the pola
Resumo do conteúdo contido na página número 5
Limitation of Liability THIS PUBLICATION IS PROVIDED "AS IS" WITHOUT WAR- THIS PUBLICATION COULD INCLUDE TECHNICAL INAC- RANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, CURACIES OR TYPOGRAPHICAL ERRORS. CHANGES INCLUDING BUT NOT LIMITED TO, THE IMPLIED WAR- ARE ADDED TO THE INFORMATION HEREIN, AT ANY RANTIES OF MERCHANTABILITY, FITNESS FOR ANY PAR- TIME, FOR THE IMPROVEMENTS OF THIS PUBLICATION TICULAR PURPOSE, OR NON-INFRINGEMENT OF THE AND/OR THE CORRESPONDING PRODUCT (S). THIRD PARTY’S RIGHT. D
Resumo do conteúdo contido na página número 6
CONTENTS Important Safety Instructions ........................................... 4 CONNECTION OF WJ-SX650 512 x 64 Limitation of Liability ........................................................ 5 FULL MATRIX SYSTEM.................................................. 35 Disclaimer of Warranty .................................................... 5 Connection with System Devices ................................. 36 Trademarks and Registered Trademarks......................... 5 System Controll
Resumo do conteúdo contido na página número 7
Alarm Arming Control ............................................. 64 To Operate Alarm-related Camera (ACK) .............. 65 To Cancel Alarms ................................................... 65 Alarm History Table ................................................ 66 WJ-HD300A Series Control .......................................... 67 Recorder Selection ................................................. 67 Displaying WJ-HD300A Series SETUP MENU ....... 67 Controlling Digital Dis
Resumo do conteúdo contido na página número 8
Preface • Central Processing Unit WJ-MPU955A is the main component of WJ-SX650 512 x 64 Full Matrix System and GX System that are network-based. • This document describes how to operate Central Processing Unit WJ-MPU955A from the Panasonic Ethernet controllers. Note: GX System is supported by NTSC model only. Features You can select one of the following systems supported by WJ-MPU955A. • GX System (NTSC model only) This system is based on the video switch nodes of MPEG2 Encoder WJ-GXE900 and MPE
Resumo do conteúdo contido na página número 9
Precautions • Refer all work related to the installation of this • We recommend that you make a note of your set- appliance to qualified service personnel or system tings and save them. installers. This will help you when a system configuration change is required or when an unexpected trouble or failure • Do not block the ventilation opening or slots on the occurs. cover. To prevent the appliance from overheating, place it at • Distributing, copying, disassembling, reverse com- least 5 cm {2 in
Resumo do conteúdo contido na página número 10
Document Convention This document uses the following convention when describing the use and operation of this unit. System Controller: Panasonic System Controller WV-CU950 CPU: Panasonic Central Processing Unit WJ-MPU955A Series Admin Console: Panasonic Administration Console (Software) MPEG2 Encoder: Panasonic MPEG2 Encoder WJ-GXE900 (NTSC model only) MPEG2 Decoder: Panasonic MPEG2 Decoder WJ-GXD900 (NTSC model only) Time Management Utility (or TMU): Panasonic Time Management Utility (Software
Resumo do conteúdo contido na página número 11
References This document will provide the product information about WJ-SX650 512 x 64 Full Matrix System and GX System. • Admin Console User's Guide • MPEG2 Encoder WJ-GXE900/MPEG2 Decoder WJ-GXD900 Operating Instructions (NTSC model only) • Time Management Utility User's Guide • Digital Disk Recorder WJ-HD300A Series Operating Instructions • Matrix Switcher WJ-SX650 Series Operating Instructions Notification about System Units The following diagram shows the available system types and component
Resumo do conteúdo contido na página número 12
This page intentionally left blank. 12
Resumo do conteúdo contido na página número 13
FEATURES OF WJ-SX650 512 x 64 FULL MATRIX SYSTEM AND GX SYSTEM 13
Resumo do conteúdo contido na página número 14
Main Features Operator Functions Video Camera Functions Operator Area Changes Camera Control The system can be divided into multiple areas (up to 64), The system provides operators with the camera control and an operator can change from one area to another if functions. The supported functions are: pan, tilt, zoom, they have the necessary permission. focus, and iris. Operator Log On and Off Camera Operation Operators are assigned a user ID and password by a sys- The system provides o
Resumo do conteúdo contido na página número 15
Tour Sequences Event Operations The function allows administrators to program system events. The event function currently supports following Program the Tour Sequences operations: This function allows administrators to program tour sequences, and store them in the system database. • Camera spot The WJ-MPU955A can execute 20 tour sequence steps in • Tour sequence around one second. If the WJ-MPU955A is asked to per- • Arm and disarm alarm form more than 20 steps in a single second, it will
Resumo do conteúdo contido na página número 16
GX System Examples (NTSC Model Only) Standard System Standard System contains one CPU. It can handle up to 256 encoder devices, up to 64 decoder devices, one administration station, and up to 64 system controllers. The IP addresses in the following diagram are the default addresses of the CPU net- work ports. Note: MPEG2 Encoder (WJ-GXE900) and MPEG2 Decoder (WJ-GXD900) support the NTSC model only. 192.168.1.10 TRIGGER OUT ALARM IN RESET ON OFF POWER 100BASE-TX TERM RS-485 4321G4321GGV + – G
Resumo do conteúdo contido na página número 17
Redundant System Redundant System requires two CPUs. It can also handle up to 256 encoder devices, up to 64 decoder devices, one adminis- tration station, and up to 64 system controllers. 192.168.1.10 TRIGGER OUT ALARM IN RESET ON OFF POWER 100BASE-TX TERM RS-485 4321G4321GGV + – G 4 3 2 1 ON OFF VIDEO IN VIDEO OUT AUDIO IN SIGNAL GND 2 1 2 1 ON 1000BASE-T 100BASE-TX RESET MIX QUAD SIGNAL GND V+ – G WJ-GXE900 4 3 4 3 OFF AUDIO OUT VIDEO OUT POWER Switching HUB 192.168.3.11 WJ-GXD900 192.168.1
Resumo do conteúdo contido na página número 18
Available System Controllers Ethernet Controllers • WJ-MPU955A supports Panasonic Ethernet controllers. • Up to 64 system controllers are connectable in the system. • IP addresses will be automatically provided to each system controller during the communication with the CPU. 18
Resumo do conteúdo contido na página número 19
WJ-SX650 512 x 64 Full Matrix System Example This system contains one CPU. The CPU can handle up to four SX650 sub nodes and two SX650 bridge nodes, one admin console and up to 64 system controllers. Each sub node should equip one Network Board WJ-PB65E01 to communicate with the CPU through the Ethernet wiring. Camera 1 - - - - Camera 256 Camera 257 - - - - Camera 512 Not used Not used Not used Not used Video Input Board (8) Video Input Board (8) Video Input Board (7) Video Input Board (7) Video