DUAL 824
SUPERVISED WIRELESS
SECURITY CONTROL PANEL
Installation & Programming Instructions
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
Resumo do conteúdo contido na página número 2
INTRODUCTION CONGRATULATIONS for selecting Linear's DUAL 824 DUAL 824 SYSTEM Security System. The Model DUAL 824P Control Panel and the Model DUAL 824KP Keypad incorporate many advanced and sophisticated features. The system can be expanded and customized to fi t the installation's specifi c needs. The DUAL 824P Control Panel and its accessories are designed and manufactured by the oldest wireless security company in North America. You can look ahead to many years of reliable service with t
Resumo do conteúdo contido na página número 3
TABLE OF CONTENTS 1. THE DUAL 824 SECURITY SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 13. ADVANCED PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CONTROL PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SETUP MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 DOOR/WINDOW SENSORS . . .
Resumo do conteúdo contido na página número 4
1. THE DUAL 824 SECURITY SYSTEM DXS-73 DXS-91 GLASS SMOKE DETECTOR DXS-10 DUAL 824KP BREAK DETECTOR † DXS-54 WIRELESS HARDWIRED PIR KEYPAD KEYPAD DXS-81 BILL TRAP † DUAL 824P CONTROL DXS-31 DXS-32 MINI † NOTE: These accessories DXT-41 & DXT-42 DXS-62A DXT-61A DXT-21 & DXT-23 PANEL DOOR/WINDOW DOOR/WINDOW are not listed by UL. REMOTES REMOTE REMOTE † REMOTES † SENSOR SENSOR The optional Model VB-2 digital voice response module can CONTROL PANEL be installed in the Control Panel. The VB-2 module
Resumo do conteúdo contido na página número 5
DOOR/WINDOW SENSORS PANIC BUTTONS The DXS-31 and DXS-32 sensors monitor doors and windows. They The DXT-21, DXS-21 single-button, and DXT-23, DXS-23 two-button send radio signals to the Control Panel. One type of signal is sent transmitters can be used as portable “panic buttons”. Pressing the when the door or window is opened, and a different type of signal is front or top button on the DXT-21 or DXS-21 at any time will trigger sent when the door or window is closed. If the system is armed,
Resumo do conteúdo contido na página número 6
2. SECURITY SYSTEM FLOOR PLAN EXAMPLE SYSTEM ✦ The example shows a typical DUAL 824 system. ✦ Any or all of the accessories shown can be used. ✦ A total of 24 sensors can be used with each Control Panel. Each wireless sensor, hardwired loop, and wireless keypad used occupies a sensor location. DESIGN THE INSTALLATION 1. Draw a fl oor plan for the installation. 2. Consider the security needs of the premises. 3. Determine which doors and windows are vulnerable to intrusion. 4. Figure which inte
Resumo do conteúdo contido na página número 7
3. OVERVIEW OF KEYPADS HARDWIRED KEYPAD ✦ One or two hardwired keypads can be used for controlling the system. ✦ Three system status indicators: READY, ARMED, & TROUBLE ✦ Three system supervisory indicators: HARDWIRED POWER, BATTERIES, & RADIO KEYPAD ✦ Five system mode indicators: OFF, CHIME, HOME, AWAY & TEST ✦ 24 system sensor indicators. ✦ Location inside beauty cover for supplied sensor identifi cation labels. ✦ Press to activate the automation output. ✦ Pressing clears the keypad. ✦ Pr
Resumo do conteúdo contido na página número 8
4. HARDWIRED KEYPAD FEATURES 7 SENSOR STATUS INDICATORS 8 ★ Blacked-out sensor status indicators are only visible when lit. 7 ★ Indicate the status of each of the system's wireless sensors and hardwired 9 loops. ★ Indicators show which doors and windows are open. ★ Indicators fl ash to display sensors that have caused an alarm. ★ Stick-on labels are provided to identify the custom sensor locations. 10 6 8 SYSTEM STATUS INDICATORS ★ Shows the current status of the system. READY LIGHT ★ Lights whe
Resumo do conteúdo contido na página número 9
5. CONTROL PANEL FEATURES 9 8 7 10 6 11 5 12 4 3 2 14 13 1 1 BATTERY FUSE 8 DIGITAL VOICE RESPONSE MODULE (OPTIONAL) ★ Type 2AG, 3-amp fuse for the backup battery. ★ The Model VB-2 gives the Control Panel's digital communicator listen-only, ★ If the keypad's POWER light is fl ashing and the optional backup battery is manual 2-way and full duplex 2-way audio capability with the Central Station. installed and charged, check this fuse. ★ The module allows remote command of the system using a standa
Resumo do conteúdo contido na página número 10
6. CONTROL PANEL INSTALLATION SYSTEM LOCATION ✎ NOTE: Wireless sensor signals must be able to reach the Control Panel. ✔ Try to centrally locate the Control Panel. USE THE CASE BOTTOM ✔ Keep Control Panel away from large metal AS A TEMPLATE TO MARK appliances. THE FOUR KEYHOLE MOUNTING HOLES ✔ Maximum recommended sensor range is 400 feet (system tested at 1000 feet). ✎ NOTE: If you don't use the wireless keypad, a hardwired keypad should be easily accessible to the usual entrance. FOR RE
Resumo do conteúdo contido na página número 11
KEYPAD SELECT TWIST SCREWDRIVER JUMPER SET IN SLOTS TO OPEN HARDWIRED KEYPAD INSTALLATION SOUNDER JUMPER TO "KEYPAD 1" THE KEYPAD CASE SET TO "ON" ✦ One or two Model DUAL 824KP keypads can be used with the DUAL 824P Control Panel (one keypad is included in the DUAL 824 system KEYPAD SELECT KEYPAD package). JUMPER CONNECTOR SOUNDER (KPD1 OR KPD2) JUMPER RSM-2 KIT ✦ The keypad is supplied with a short wiring RSM-2 KIT (ON OR OFF) DEFAULT JUMPER POSITIONS MICROPHONE SPEAKER LOCATION LOCATION ha
Resumo do conteúdo contido na página número 12
RUN LOOP WIRING HARDWIRED LOOP WIRING BETWEEN THE CONTROL PANEL AND THE REMOTE ✦ The DUAL 824 supports up to eight normally HARDWIRED SENSORS open/closed hardwired loops each with 2.2K 4-CONDUCTOR FOR HARDWIRED end-of-line resistor supervision. INFRAREDS ✦ Each hardwired loop that is wired and 2-CONDUCTOR FOR MAGNETIC programmed uses one sensor location. CONTACTS ✦ Each hardwired loop can be programmed to any RUN 4-CONDUCTOR WIRE TO POWERED DEVICES sensor number. ✦ Each hardwired loop can
Resumo do conteúdo contido na página número 13
EXTERNAL ALARM SIREN CONNECTION ✦ An external siren alerts occupants and neighbors with a loud siren during alarm. EXTERNAL ✦ Use a 12 volt, 1 amp maximum rated weather- ALARM resistant horn speaker with a built-in siren driver. SIREN Do not use a plain speaker without a siren driver. ✎ NOTE: Connection of an electromechanical bell or motor bell is not recommended because of the radio interference generated when the bell is running. MAIN TERMINAL BLOCK COM LOOP H/A H/A RLY RLY RLY +12 8 - + C
Resumo do conteúdo contido na página número 14
AUTOMATION OUTPUT CONNECTION MAIN TERMINAL BLOCK LOOP H/A H/A RLY ✦ The Control Panel provides a Automation Output 8 - + COM ANY SENSOR CAN to control lights, devices and appliances. BE PROGRAMMED TO TOGGLE THE AUTOMATION ✦ Automation Output can connect to most popular OUTPUT home automation devices and other simple electronic devices (see fi gure). THE POSITIVE H/A TERMINAL PROVIDES ✦ Press to turn the Automation Output on, +12 VOLTS DC AND IS CURRENT LIMITED AT 40 MILLIAMPS MAXIMUM pre
Resumo do conteúdo contido na página número 15
CONTROL PANEL POWER CONNECTION MAIN TERMINAL BLOCK KEYPAD XFRMR ✦ The Control Panel is powered by a low voltage KPD KPD KPD KPD KPD AC AC - CLK DAT SPK + SPK- plug-in transformer. ✦ Use up to 25 feet of 20 AWG or larger 2-conductor wire to connect the transformer to the Control Panel. 1. Route the power wires from the plug-in PLUG-IN TRANSFORMER transformer to the Control Panel. 16 VAC, 28 VA BE SURE TO SELECT AN UN-SWITCHED AC OUTLET 2. Connect the wires to the transformer terminals FOR TH
Resumo do conteúdo contido na página número 16
7. BASIC CONTROL PANEL PROGRAMMING ✦ In a new installation, when power is fi rst applied the system's master user code is “1234”. SETTING A CREATE THE MASTER USER CODE ENTERING NEW MASTER SETUP ✎ NOTE: Local programming must be entered on USER CODE MODE the system's hardwired keypad, not on a wireless keypad. START IN SETUP MODE START IN OFF MODE 1. Press (clears keypad if any other keys have CLEARS been pressed). KEYPAD PROGRAMMING 2. Place the system in Test Mode (enter 1234 and STEP #9
Resumo do conteúdo contido na página número 17
PROGRAM THE HARDWIRED LOOPS START IN TEST ✦ Each hardwired loop used must be programmed into the Control Panel's memory. ✦ Each hardwired loop programmed uses one of MASTER the twenty four available sensor locations. USER 1. Start with the system in Test Mode (enter the CODE master user code and press TEST). 2. Enter the Setup Mode from Test Mode, enter the master user code then press TEST again. 1 GONG & 5 BEEPS ✴ A “Gong” and fi ve “Beeps” will sound. The system is now (SETUP MODE) in Setu
Resumo do conteúdo contido na página número 18
PROGRAMMING DIFFERENT SENSOR TYPES ✦ Follow the instructions on the previous page to select a sensor number to program the sensor into. ✎ NOTE: A sensor can be programmed into more than one location. Be sure to choose an UNUSED sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. DXS-10 ✦ To add DXS-10 wireless keypads, press and hold the keypad's key until programmed into the Control Panel. ✦ For DXS-31 and DXS-32
Resumo do conteúdo contido na página número 19
PROGRAMMING DIFFERENT SENSOR TYPES (CONT.) ✦ For DXT-61, DXT-21, DXS-21, DXT-41, & DXS-62A single-button remotes, simply press the unit's button. ✎ NOTE: After the Control Panel recognizes the transmitter, single-button remotes must be re-programmed as “panic buttons” or home automation controllers. Refer to Page 28 in the “Customizing the System” section of this manual. ✦ For DXT-23, DXS-23, & DXT-42 multi-button DXT-21 remotes: Learn the transmitter by pressing the left button. The rem
Resumo do conteúdo contido na página número 20
8. BASIC SENSOR INSTALLATION ✦ Each accessory sensor is packaged with its FROM TOP OF CASE TWIST own set of installation instructions specifi c to the SCREWDRIVER BETWEEN model of sensor. CASE HALVES UNTIL IT POPS OPEN ✦ Refer to the sensor's instructions for details on installing, operating, and testing of the sensor. ✦ Following are basic instructions for installing two popular DUAL 824 accessories: The Model DXS-10 Wireless Remote Keypad and the Model DXS-31 & DXS-32 Door/Window Transm