Resumo do conteúdo contido na página número 1
ICP-CC488
Installation Guide
ICP-CC488 Control
EN Panel
Resumo do conteúdo contido na página número 2
ICP-CC488 | Installation Guide | Notices EN | 2 Copyright Notice Notice of Liability Unless otherwise indicated, this publication is the This material is designed for use by tradespeople copyright of Bosch Security Systems, Inc. (“Bosch”). with expertise in the installation of this product. All rights are reserved. Persons without appropriate expertise should seek assistance before attempting installation. You may download a single copy of this publication. While care has been taken in
Resumo do conteúdo contido na página número 3
ICP-CC488 | Installation Guide | Contents EN | 3 5.2 Master Code Functions ................................27 5.2.1 Arm or Disarm Both Areas at the Same Contents Time................................................................27 1.0 Introduction......................................................8 5.2.2 Changing and Deleting User Codes...........27 1.1 ICP-CC488 Features .......................................8 5.2.3 Changing and Deleting Remote Radio User 1.2 Quick Start....
Resumo do conteúdo contido na página número 4
ICP-CC488 | Installation Guide | Contents EN | 4 7.4.9 Command 999 – Display the Panel Type or 13.2.1 User Codes.....................................................54 Software Version Number........................... 39 13.3 User Code Priority........................................55 7.5 Disable Factory Defaults.............................. 39 14.0 Zone Information..........................................56 8.0 Alarm Link Software.................................... 40 14.1 Day
Resumo do conteúdo contido na página número 5
ICP-CC488 | Installation Guide | Contents EN | 5 15.27 System Status Reporting Options............... 69 19.5 User Code Allocations..................................86 15.28 Test Reporting Time .................................... 69 19.6 Setting Up and Programming Codepads for Partitioning.....................................................86 15.29 Test Reporting Dialer Options ................... 70 19.6.1 Setting Up the Master Partitioned Codepad 16.0 Programmable Outputs.........
Resumo do conteúdo contido na página número 6
ICP-CC488 | Installation Guide | Contents EN | 6 24.4 New Zealand Telepermit Notes................ 100 Figure 28: Telecom Connection Diagram for China ...................................................................98 24.5 A-Tick........................................................... 101 25.0 Programming Sheets .................................. 101 25.1 ICP-CC488 Programming Sheets............. 101 Tables Table 1: Zone Defaults for the ICP-CC488..........9 26.0 Country Cod
Resumo do conteúdo contido na página número 7
ICP-CC488 | Installation Guide | Contents EN | 7 Table 40: Example Reporting in 4 + 2 Format ... 44 Table 41: 4 + 2 Reporting Format......................... 44 Table 42: 4 + 2 Transmission Code Descriptions45 Table 43: Point ID Codes....................................... 46 Table 44: Zone Status Display ............................... 48 Table 45: Dialing Digits .......................................... 49 Table 46: Telco Arm/Disarm Dialing Digits ....... 51 Table 47: Priority Lev
Resumo do conteúdo contido na página número 8
ICP-CC488 | Installation Guide | 1.0 Introduction EN | 8 1.1 ICP-CC488 Features 1.0 Introduction The ICP-CC488 security system uses the latest in microprocessor technology to provide you with Congratulations on selecting the ICP-CC488 Control useful features, and superior reliability and Panel for your installation. Take the time to read performance. through this guide and familiarize yourself with the outstanding operating and installation features of this The control panel provi
Resumo do conteúdo contido na página número 9
ICP-CC488 | Installation Guide | 1.0 Introduction EN | 9 Enter command [9 6 0] and press [AWAY] to exit 1.2 Quick Start from Installer’s Programming Mode. The following steps allow you to use the ICP-CC488 Two beeps sound and the STAY and AWAY Control Panel with factory default values. The default indicators are extinguished. The system is values allow the control panel to communicate in the returned to the disarmed state and is ready for Contact ID format. If you are not familiar
Resumo do conteúdo contido na página número 10
ICP-CC488 | Installation Guide | 2.0 Codepad Indicators EN | 10 1.2.3 Zone Types Zone Indicators There are thirteen zone types to choose from when Table 3: Zone Indicators programming zones for the ICP-CC488 Control Panel. Refer to Section 14.3 Zone Programming for more information. Indicator Definition On The zone is unsealed. Table 2: Zone Types Off The zone is sealed. Flashing fast The zone is in alarm. (0.25 sec. on/ Type Description Type Description 0.25 sec. off) 0 In
Resumo do conteúdo contido na página número 11
ICP-CC488 | Installation Guide | 2.0 Codepad Indicators EN | 11 MAINS Indicator 2.2 ICP-CP508LW Eight Zone LCD The MAINS indicator displays whether the system’s Codepad AC MAINS supply is normal or failed. Figure 2: ICP-CP508LW Eight Zone LCD When programming in Installer’s Programming Codepad Mode or using a Master Code function, the MAINS indicator lights to indicate a location value from 10 to 15. The MAINS indicator represents the 10 digit, which is added to the value of the
Resumo do conteúdo contido na página número 12
ICP-CC488 | Installation Guide | 2.0 Codepad Indicators EN | 12 Audible Indicators • Section 3.5 to arm the system in STAY Mode 2. The codepad provides a number of audible • Section 5.1.5 to use the Installer Code to set zones indications. Refer to Table 8 on page 11. to be automatically isolated in STAY Mode 2. 2.3 ICP-CP500PW Master Partitioned • Section 5.2.6 to use the Master Code to set zones to be automatically isolated in STAY Mode 2. LED Codepad System Disarmed Figure 3:
Resumo do conteúdo contido na página número 13
ICP-CC488 | Installation Guide | 2.0 Codepad Indicators EN | 13 Each time a new system fault is detected (the FAULT Table 10: Area On/Off Indicators indicator flashes), the codepad beeps once per min. Press [AWAY] to stop the beeping and to Indicator Definition acknowledge the fault. On The area is armed in AWAY PARTIAL Indicator Mode or STAY Mode 1. The PARTIAL indicator lights when the system is Off The area is disarmed. armed in STAY Mode 1. The PARTIAL indicator Area Displa
Resumo do conteúdo contido na página número 14
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 14 3.2 Disarming the System from AWAY 3.0 System Operations Mode This section explains the general operations of the When you enter the premises after the system is system: arming and disarming the system in the three armed in AWAY Mode, you must disarm the system modes, isolating zones, initiating codepad alarms, from AWAY Mode to disable detection devices that and determining a fault. activate the sirens, strobe, and be
Resumo do conteúdo contido na página número 15
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 15 To arm the system in STAY Mode 1 (method To disarm the system from STAY Mode 1 one): (method two): 1. Enter your code and press [STAY]. A flashing zone indicator represents a previous alarm 2. Two beeps sound and the STAY indicator is lit. in that zone. If this is the case, a valid User Code is Exit Time starts. required to disarm the system using method one. To enable method two, Option 4 in Location 497 must The indica
Resumo do conteúdo contido na página número 16
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 16 The indicators for any zones that are programmed to 3.7 Codepad Duress Alarm be automatically isolated in STAY Mode 2 flash until Figure 6: ICP-CP500PW LED Codepad the Exit Time expires. At the end of Exit Time, the Showing Audible Alarm Buttons zone indicators are extinguished and the codepad sounds one short beep. If a zone is not sealed at the end of Exit Time, the zone is automatically isolated and is lit constantly
Resumo do conteúdo contido na página número 17
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 17 3.11.1 Standard Isolating 3.9 Codepad Fire Alarm Standard isolating allows any operator to isolate An audible codepad Fire Alarm activates when a zones because no code is required. user presses [4] and [6] on the remote codepad simultaneously. A distinct fire sound emits through 1. Press [STAY] twice. Three beeps sound and the STAY indicator the horn speaker to indicate this type of alarm. The fire sound is different t
Resumo do conteúdo contido na página número 18
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 18 5. Press [AWAY]. 4 – Sensor Watch Fault Two beeps sound and the system returns to the This fault occurs when one or more detection devices disarmed state. fails to detect an intrusion while disarmed for the The indicators for the selected zones continue to time period programmed in Locations 476 and 477 flash until the next time the system is disarmed. (refer to Section 15.5 Zone Status – Sensor Watch Example Reports
Resumo do conteúdo contido na página número 19
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 19 AC MAINS Failure Table 14: System FAULT indicators An AC MAINS supply failure automatically flashes the MAINS indicator. If the AC MAINS supply is Indicator Fault Description disconnected continuously for longer than 2 min, the 1 Low battery remote codepad beeps the codepad buzzer once per This fault registers when the system detects min. If the control panel is programmed to report an a low capacity backup battery. T
Resumo do conteúdo contido na página número 20
ICP-CC488 | Installation Guide | 4.0 Remote Radio Transmitter Operations EN | 20 Table 15: Fault Analysis Conditions Zone Indicator Fault Description Hold Down Button Zone Indicator Fault Condition 1 System fault 1 1 Low battery 2 Date and time 3 RF receiver jamming RF receiver tamper switch RF receiver communications fail 4 Horn speaker 5 Telephone line fail 6 EEPROM fail 7 AUX Power Supply fail 2 RF low battery 2 1 to 16 Zones 1 to 16 RF low battery