Resumo do conteúdo contido na página número 1
®
# 42390
SUMMIT
BUILT-IN LP TANK ENCLOSURE KIT
®
Summit Built-In LP Tank Enclosure Kit
(Model #: 21287)
THESE ACCESSORIES MAY BE PURCHASED SEPARATELY.
YOU MUST READ THIS OWNERS GUIDE
WARNING: Follow all leak-check
BEFORE OPERATING YOUR GAS GRILL
procedures carefully in this manual prior
to barbecue operation. Do this even if the
DANGER
barbecue was dealer-assembled.
If you smell gas:
1. Shut off gas to the appliance.
WARNING: Do not try to light this
2. Extinguish any open
Resumo do conteúdo contido na página número 2
DANGERS & WARNINGS DANGER Failure to follow the Dangers, Warnings and Cautions contained in this Owner's Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property. WARNINGS Do not store a spare or disconnected liquid propane cylinder under or near the barbecue. Improper assembly may be dangerous. Please carefully follow the assembly instructions in this manual. ® Do not operate the Weber gas barbecue if there is a gas leak present.
Resumo do conteúdo contido na página número 3
WARRANTY OPERATING THEREFORE, YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE. ® WARNING: Only use the Weber Tank Enclosure Kit This Limited Warranty shall be limited to the repair or replacement of outdoors in a well-ventilated area. Do not use in a ga- parts that prove defective under normal use and service and which on examination shall indicate, to Weber’s satisfaction, they are defective. rage, building, breezeway or any other enclosed area. ® Before returning any parts, contact the Cust
Resumo do conteúdo contido na página número 4
ASSEMBLY of the fl oor. The ventilation openings should be of equal Typical 20 LP propane gas supply Instal- size and be spaced at a minimum of 90 degrees, and lation should be unobstructed. ® We strongly recommend that you use the Summit Built-In 3). The minimum size of the ventilation hole (s) should Tank Cabinet (#21280) for installations using a 20 lb LP cyl- not be less than 1/4 inch. inder, mounted remotely in an “island” structure. 4). The ventilation openings in the sidewalls should
Resumo do conteúdo contido na página número 5
Any Surface 24 inches 24 inches Any Surface ASSEMBLY e). There should be a minimum of 2 inches (50.8mm) be- LOCATING YOUR LP TANK ENCLOSURE tween the ground and the fl oor of the remote LP cylinder KIT enclosure. When determining a suitable location for your LP Tank f). The LP cylinder valve should be readily accessible Enclosure Kit installation, give attention to concerns such for hand operation. A door on the remote LP cylinder as proximity to traffi c paths, and keeping any gas supply
Resumo do conteúdo contido na página número 6
ASSEMBLY PARTS LIST 1 Hose and regulator - 1 4 Tank stand - 1 8 4 Tank stand base - 1 2 Tank Scale - 1 1/4-20 nut - 6 2 Nylon washer - 12 4 1/4-20 x 1/2" bolt - 6 2 Cylinder glide - 2 2 1/2" Flare Gasket - 2 3/8" Flare Gasket - 2 6
Resumo do conteúdo contido na página número 7
ASSEMBLY MOUNTING THE LP TANK BRACKET Mount the LP tank bracket to the right hand side of the enclosure opening using non corrosive hardware.. Mounting holes are provided on the sides and bottom of your LP tank bracket. Be sure to mount the bracket securley to the enclosure before use. MOUNTING HARDWARE NOT INCLUDED. 3 MOUNTING THE LP HOSE AND REGULATOR Securley mount the hose and regulator bracket to the top of the built-in tank enclosure using non corrosive hardware. MOUNTING HARDWARE NOT INC
Resumo do conteúdo contido na página número 8
GAS INSTRUCTIONS top of 1) Connect the corrugated gas line to the manifold located box on the right hand side of grill under the control panel. Corrugated Gas Line to Manifold Use the 1/2" fl ared gasket(1) to ensure proper seal. 90º fitting Cap back of (Optional Side Burner) box Connection to LP Tank Side View CONNECT GAS SUPPLY A 58" inch corrugated gas line is supplied with the grill. This line needs to pass through the gas inlet opening to the main gas supply. (1) top view FILL LIQUID P
Resumo do conteúdo contido na página número 9
GAS INSTRUCTIONS Note: This connection tightens clockwise and will not allow CONNECTING THE LIQUID PROPANE CYLINDER gas to fl ow unless the connection is tight. The connection WARNING: Make sure that the LP cylinder valve is closed. Close by turning valve clockwise. requires tightening by hand only. WARNING: Do not use a wrench to tighten the con- DANGER nection. Using a wrench could damage the regulator coupling and could cause a leak. Do not use an open fl ame to check for gas 5) Mix
Resumo do conteúdo contido na página número 10
GAS INSTRUCTIONS Note - Since some leak test solutions, including soap and CHECK FOR GAS LEAKS water, may be slightly corrosive, all connections should be After a period of nonuse, we recommend that you perform the following maintenance procedures for your safety. rinsed with water after checking for leaks. Make sure side burner is OFF. WARNING: Check the hose before each use of the To perform leak checks: open cylinder valve by turning the grill for nicks, cracking, abrasions or cuts. If
Resumo do conteúdo contido na página número 11
GAS INSTRUCTIONS REFILLING THE LIQUID PROPANE CYLINDER Safe handling tips for Liquid Propane Gas We recommend that you refi ll the LP cylinder before it is Cylinders completely empty. Liquid Propane (LP) gas is a petroleum product as are Removal of the LP cylinder gasoline and natural gas. LP gas is a gas at regular 1) Close cylinder valve (turn clockwise). temperatures and pressures. Under moderate pressure, 2) Unscrew regulator coupling by turning counterclockwise, inside a cylinder, L
Resumo do conteúdo contido na página número 12
GAS INSTRUCTIONS The cylinder should be constructed and marked in ac- Liquid Propane (LP) Cylinder(s) cordance with the Specifi cations for LP - Gas Cylinders The joint where the hose connects to the LP cylinder must of the U.S. Department of Transportation (D.O.T.) or the be leak tested each time the LP cylinder is reconnected. National Standard of Canada, CAN/CSA-B339, Cylin- For example, test each time the LP cylinder is refi lled. ders, Spheres and Tubes or Transportation of Dangerous