Resumo do conteúdo contido na página número 1
ENGLISH ESPAÑOL
Owner’s Manual/Manual Del Propietario
GARAGE DOOR OPENER
ABRIDOR DE PUERTA DE COCHERA
For Residential Use Only/Sólo para uso residencial
Model/Modelo 139.53939D
Read and follow all safety rules Leer y seguir todas las reglas de
and operating instructions before seguridad y las instrucciones de
first use of this product. operación antes de usar este
producto por primera vez.
Guardar este manual cerca de la
Fasten the manual near the garage
puerta de la cochera.
door after instal
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS Adjustment 27-29 Introduction 2-7 Program the travel limits . . . . . . . . . . . . . . . . . . . . . .27 Safety symbol review and signal word review . . . . . . . . .2 Setting the force . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . .3 Test the safety reversal system . . . . . . . . . . . . . . . . .29 Tools needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 ® Test The
Resumo do conteúdo contido na página número 3
1 Preparing your garage door Before you begin: To prevent possible SERIOUS INJURY OR DEATH: • Disable locks. • ALWAYS call a trained door systems technician if garage • Remove any ropes connected to garage door. door binds, sticks, or is out of balance. An unbalanced • Complete the following test to make sure your garage garage door may not reverse when required. door is balanced and is not sticking or binding: • NEVER try to loosen, move or adjust garage door, door springs, cables, pulleys,
Resumo do conteúdo contido na página número 4
— — — — — — — — • Do you have an access door in addition to the garage Planning door? If not, Model 139.53702 Emergency Key Identify the type and height of your garage door. Survey Release is required. See Accessories page. your garage area to see if any of the conditions below • Look at the garage door where it meets the floor. Any apply to your installation. Additional materials may be gap between the floor and the bottom of the door must required. You may find it helpful to ref
Resumo do conteúdo contido na página número 5
Planning (Continued) ONE-PIECE DOOR INSTALLATIONS Without a properly working safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED • Generally, a one-piece door does not require or KILLED by a closing garage door. reinforcement. If your door is lightweight, refer to the • The gap between the bottom of the garage door and the information relating to sectional doors in Installation floor MUST NOT exceed 1/4" (6 mm). Otherwise, the safety Step 12. reversal system
Resumo do conteúdo contido na página número 6
Carton Inventory Your garage door opener is packaged in one carton material. Parts may be stuck in the foam. Hardware for which contains the motor unit and all parts illustrated assembly and installation is shown on the next page. below. Accessories will depend on the model purchased. Save the carton and packing material until installation If anything is missing, carefully check the packing and adjustment is complete. ® SECURITY✚ 3-Function Mini Remote Control (1) ® SECURITY✚ Battery 3-Functio
Resumo do conteúdo contido na página número 7
Hardware Inventory Separate all hardware and group as shown below for the assembly and installation procedures. ASSEMBLY HARDWARE Lock Nut Lock Washer Nut Spring/Trolley Nut (1) 1/4"-20 (2) 3/8" (1) 3/8" (1) Bolt 1/4"-20x1-3/4" (2) Master Idler Bolt (1) Link (2) Trolley Threaded Shaft (1) INSTALLATION HARDWARE Carriage Bolt Handle Ring Nut 5/16"-18 (6) Wing Nut 1/4"-20x1/2" (2) Fastener (3) 1/4"-20 (2) Lag Screw Hex Bolt Insulated 5/16"-9x1-5/8" (2) 5/16"-18x7/8" (4) Staples (30) Lock Washer
Resumo do conteúdo contido na página número 8
ASSEMBLY STEP 1 Assemble the Rail and Install the Trolley To prevent INJURY from pinching, keep hands and fingers away from the joints while assembling the rail. To avoid installation difficulties, do not run the garage door opener until instructed to do so. The front rail has a cut out “window” at the door end (see 3. Place the motor unit on packing material to protect the illustration). The hole above this window is larger on cover, and rest the back end of the rail on top. For the top of the
Resumo do conteúdo contido na página número 9
ASSEMBLY STEP 2 Fasten the Rail to the Motor Unit To avoid SERIOUS damage to garage door opener, use ONLY those bolts/fasteners mounted in the top of the opener. • Insert a 1/4"-20x1-3/4 bolt into the cover protection bolt hole on the back end of the rail as shown. Tighten securely with a 1/4"-20 lock nut. Do NOT overtighten. • Remove the two bolts from the top of the motor unit. • Place the “U” bracket, flat side down, on the motor unit and align the bracket holes with the bolt holes. Fasten wi
Resumo do conteúdo contido na página número 10
ASSEMBLY STEP 4 Install the Belt and Attach the Belt To avoid possible SERIOUS INJURY to fingers from moving Cap Retainer garage door opener: • ALWAYS keep hand clear of belt pulley while operating 1. Pull the belt around the idler pulley and toward the opener. trolley. The ribbed side must contact the pulley. • Securely attach belt pulley cover BEFORE operating. 2. Hook the trolley connector into the retaining slot on the trolley as shown. 3. With the trolley against the screwdriver, dispense t
Resumo do conteúdo contido na página número 11
ASSEMBLY STEP 5 Set the Tension • Insert a screwdriver tip into one of the nut ring slots and brace it firmly against the trolley. • Place a 7/16" open end wrench on the square end. Rotate the nut about 1/4 turn until the spring releases and snaps the nut ring against the trolley. This sets the spring to optimum belt tension. Nut Ring Slot Square End You have now finished assembling your garage door opener. Please read the following warnings before proceeding to the installation section. Trolley
Resumo do conteúdo contido na página número 12
INSTALLATION STEP 1 Unfinished Ceiling Determine the Header Bracket OPTIONAL CEILING Location MOUNT FOR HEADER BRACKET Header Wall 2x4 To prevent possible SERIOUS INJURY or DEATH: Vertical Centerline of Garage Door • Header bracket MUST be RIGIDLY fastened to structural 2x4 support on header wall or ceiling, otherwise garage door Structural Supports might not reverse when required. DO NOT install header bracket over drywall. • Concrete anchors MUST be used if mounting header bracket or 2x4 into
Resumo do conteúdo contido na página número 13
Wall Mount INSTALLATION STEP 2 Install the Header Bracket You can attach the header bracket either to the wall UP above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided). Optional Mounting Holes WALL HEADER BRACKET INSTALLATION • Center the bracket on the vertical centerline with the Vertical bottom edge of the bracket o
Resumo do conteúdo contido na página número 14
INSTALLATION STEP 3 Attach the Rail to the Header Bracket NOTE: (Optional) With some existing installations, you may re-use the old header bracket with the two plastic spacers included in the hardware bag. Place the spacers inside the bracket on each side of the rail, as illustrated. • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way, you will need help. Have someone hold the opener securely on a t
Resumo do conteúdo contido na página número 15
INSTALLATION STEP 4 Position the Opener To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door. Follow instructions which apply to your door type as illustrated. SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal door-to-rail distance. Rail • Remove foam packaging. • Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough. • Open the door all the way and place
Resumo do conteúdo contido na página número 16
INSTALLATION STEP 5 Hang the Opener To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of Three representative installations are shown. Yours may the garage. Concrete anchors MUST be used if installing any be different. Hanging brackets should be angled brackets into masonry. (Figure 1) to provide rigid support. On finished ceilings (Figures 2 and 3), attach a sturdy metal bracket to structural supports before installing the opener. This
Resumo do conteúdo contido na página número 17
INSTALLATION STEP 6 Install the Control Console To prevent possible SERIOUS INJURY or DEATH from electrocution: Locate control console within sight of door, at a minimum • Disconnect ALL electric and battery power BEFORE height of 5 feet (1.5 m) where small children cannot performing ANY service or maintenance. reach, away from moving parts of door and door • Connect ONLY to 24 VOLT low voltage wires. hardware. If installing into drywall, drill 5/32" holes and To prevent possible SERIOUS INJURY
Resumo do conteúdo contido na página número 18
NOTICE INSTALLATION STEP 7 Battery Battery Cover Install the Battery • Make sure motor unit is unplugged. • Using a Phillips head screwdriver, remove the battery cover on the motor unit. • Partially insert battery into motor unit with terminals facing out. • Connect the red (+) and black (-) wires from motor unit to corresponding terminals on battery. • Replace battery cover. INSTALLATION STEP 8 Install the Lights To prevent possible OVERHEATING of the endpanel or light socket: • Press the rel
Resumo do conteúdo contido na página número 19
INSTALLATION STEP 10 Electrical Requirements To prevent possible SERIOUS INJURY or DEATH from electrocution or fire: To avoid installation difficulties, do not run the • Disconnect ALL electric and battery power BEFORE opener at this time. performing ANY service or maintenance. To reduce the risk of electric shock, your garage door • Garage door installation and wiring MUST be in compliance opener has a grounding type plug with a third grounding with ALL local electrical and building codes. pin.
Resumo do conteúdo contido na página número 20
INSTALLATION STEP 11 ® Install The Protector System Be sure power is NOT connected to the garage door opener (Safety Sensors) BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from a closing The safety reversing sensor must be connected and garage door: aligned correctly before the garage door opener will • Correctly connect and align the safety reversing sensor. move in the down direction. This required safety device MUST NOT be disabled. • Install the safety rev