Resumo do conteúdo contido na página número 1
3511035556
¤
®
Series
IS, ISL, IC, H
Includes Remote Control
and SERIES II Electronics
Included Wall Control MUST be installed prior to operation of this Garage
Door Operator
®
Safe-T-Beam Safety Reverse System Must be installed to close door
NOTE: Your Residential Operator comes with a Rail Assembly
which is standard for up to a 7 foot 6 inch high door. An extension
kit for an 8 foot high door is available.
For Answers and Assistance:
1.800.354.3643
or visit www.geniecompa
Resumo do conteúdo contido na página número 2
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM PRE-INSTALLATION CHECK LIST Things to consider if you are planning to “do-it-yourself.” Whether you are replacing an existing garage door operator or installing an operator in your garage for the first time, there are some pre-installation issues which need to be addressed. They are as follows: 2 The Genie Company recommends that you read and fully understand all information and instructions contained herein before choosing a “do-it-yourself ” inst
Resumo do conteúdo contido na página número 3
TYPICAL SECTIONAL DOOR INSTALLATION 2 5 1 ADDED TYPICAL HEADER BRACKET SUPPORT MOUNTING BOARD BRACKET 3 BRACES 36” POWER CORD TO 120V GROUNDED OUTLET EXTENSION SPRING OR TORSION SPRING 4 3 6 3 ® SAFE-T-BEAM 7 TYPICAL 1-PIECE DOOR INSTALLATION 1-PIECE DOOR SECTIONAL DOOR
Resumo do conteúdo contido na página número 4
RECOMMENDED TOOLS TABLE OF CONTENTS SECTION PAGE PRE-INSTALLATION CHECK LIST . . . . . . . . . . . . . . . . 2-3 Carpenter’s level TOOLS REQUIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 SAFETY FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 OPERATIONAL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . 5 PARTS LISTS AND ILLUSTRATIONS . . . . . . . . . . . . . . . . . 5-8 Adjustable wrench POWER HEAD . . . . . . . . . . . . . . . . . .
Resumo do conteúdo contido na página número 5
POWER HEAD EXPLODED VIEW FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 41 Power Head Assembly E [ ] F 1 N R D 5 B 48 G 5 C P A 49 42 J K N L 45 H 39 M 4 POWER HEAD PARTS LIST Item Part Name Item Part Name 1Power Head Assembly MTerminal Strip NNo. 8-32 x 1/2" Hex Washer Head Screw ACover (By Series/Model) B Front Plate Assembly PNo. 8-32 x 3/8" Slot Hex Washer Head Screw RCapacitor Isolator C Light Socket D Motor Parts 45 Bumper 4 1/4-20 Shoulder Bolt E Receiver
Resumo do conteúdo contido na página número 6
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 1-PIECE RAIL HARDWARE EXPLODED VIEW 1-Piece Rail & Screw Assembly [ ] 2 ® NOTE:The operator will not function properly unless the Safe-T-Beam sensors are installed and the force controls adjusted. 6 1 6 5 15A 16 OR 44 39 4 45 22 9 2 15B 9 20 46 47 24 22 13 10 24 25 23 21 25 28 17 18 27 26 PARTS LIST PARTS LIST Parts Required Parts Required Item Part Name Item Part Name 1 Piece 3-Piece 1 Piece 3-Piece 1 Power Head Assembl
Resumo do conteúdo contido na página número 7
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 3-PIECE RAIL HARDWARE EXPLODED VIEW 3-Piece Rail & Screw Assembly [ ] 3 ® NOTE: The operator will not function unless the Safe-T-Beam system is installed and the force controls are properly set. 7 6 5 15A 16 44 11 12 9 1 4 3A 8 7 3B 22 39 15B 9 45 9 24 10 3C 20 25 28 46 23 47 17 13 24 22 18 27 25 26 21 PARTS LIST Parts Required Item Part Name 1 Piece 3-Piece 33 Wall Console varies varies 34 #6 x 1-1/4” Pan Head Screw 2 2 35 Ent
Resumo do conteúdo contido na página número 8
PARTS IDENTIFICATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 29 8 36 35 remotes 37 vary by model 50 43 19 31 38 33 NOTE: Accessories vary by model. FASTENERS - Shown full size. See Parts List for description. 4 22 39 1/4" x 2" Lag screw Coupler 1/4" Shoulder bolt w/flange 5 24 40 1/4" Flange nut Clevis pin #10 x 1-1/4" Phillips hex head screw 41 6 25 OR #8 x3/8" Hex flange head screw Cotter pin Carriage stop (not to scale) 8 27 42 5/16" Shoulder bolt w/flange #8 x 3/8" Pan head screw 3/8" H
Resumo do conteúdo contido na página número 9
SAFETY INFORMATION PRE-INSTALLATION WARNING OVERVIEW OF IMPORTANT POTENTIAL HAZARDS Garage doors are large, heavy objects that move with the help of springs INSTALLATION under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of INSTRUCTIONS others depend on you reading the information in this manual. If you have 9 questions or do not understand the information presented, call your nearest service r
Resumo do conteúdo contido na página número 10
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM SECT 1—MAIN ASSEMBLY OPEN BLUE PARTS BAG NOTE: 3-piece rail assembly is for doors up to coupler and including 7 feet 6 inches high. An extension 10 for 8 feet doors is available. 1. Set power head so that front panel (with end of shaft and rail attachment flange) is facing up. Fig. 1-1. serial no. NOTE: If you have this type Carriage Stop, skip bumper Step 2. DO NOT install Bumber. Fig. 1-1 2. Install bumper [45]. P eel protective paper from glue side
Resumo do conteúdo contido na página número 11
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM MAIN ASSEMBLY 6. Attach “middle” rail section [3B]. Select “middle” rail section. (This section looks identical on both ends with each set of holes being about 4 inches apart.) Fig. 1-6. 11 F ind arrows stamped into side of rail. Fig. 1-7. Align rail so arrows point away from power head. Slide screw toward power head so it sticks out end of rail section about 2 inches. Fig. 1-5 middle rail section end rail section Fig. 1-6 Fig. 1-7 [ ] 4 1/4
Resumo do conteúdo contido na página número 12
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM MAIN ASSEMBLY Slide a collar [11] over exposed end of screw on “middle” rail as far as it will go. slide collar Fig. 1-8. Engage “hook” on “middle” rail with “hook” 12 on “first” rail section. Fig. 1-9. Slide collar toward power head so that it now covers hooks. Fig. 1-10. Snap a clip [12] onto screw behind collar to hold collar in place. Fig. 1-11. Slide middle rail against first rail. Fig. 1-8 Place rail clamp [7] on each side of joint
Resumo do conteúdo contido na página número 13
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM MAIN ASSEMBLY NOTE: If installing an extension kit for an carriage stop 8 feet high door, refer to the instructions included with the extension kit now. 7. Attach “end” rail section [3C]. 13 Attach “end” rail in same way as “middle” rail USES BUMPER (step 5). (“End” rail section screw has “hook” OR on one end only.) carriage stop 8. Flip power head/rail assembly over (upside down), so that entire length of screw is visible from above. 9. Install
Resumo do conteúdo contido na página número 14
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM MAIN ASSEMBLY release OPEN GREEN PARTS BAG Screws for attaching light cover are included in this bag. knob Please set aside for use later. 14. Attach emergency release knob, cord 14 and tag. cord T ie an overhand knot in one end of Fig. 1-17 emergency release cord [17]. – Slide cord through center of knob [18]. Fig. 1-17. – Slide cord through hole in emergency release lever (on carriage). – Tie a second knot in this end. Fig. 1-18. tag – Slip wire
Resumo do conteúdo contido na página número 15
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM SECT 2—INSTALLATION NOTE: There are differences in installations TYPICAL TRACKLESS CENTERLINE depending on which type of door you have. These differences are explained throughout this section. Please note those steps which are 15 applicable to your particular door. garage door REFER TO PAGES 2 & 3. There are two basic types of residential garage doors. They are: floor SECTIONAL DOORS—divided into a set of TYPICAL TRACK GUIDED narrow panels (usually fo
Resumo do conteúdo contido na página número 16
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM INSTALLATION 2. Finding highest point of travel. SECTIONAL DOORS While raising garage door manually, watch top edge of door to see where it reaches its highest point. This is called “highest point of Highest point of travel. 16 travel.” Fig. 2-2. Measure from here to floor A locking pliers can be used to hold the door in position by clamping it onto the rail. (A stool, chair, table or any object that can safely support door will also work.) –Wi
Resumo do conteúdo contido na página número 17
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM INSTALLATION NOTE: If torsion spring interferes with your wooden plate fastened to wall studs ceiling final location, mark bracket location 2-1/2" or 6" above torsion spring depending on garage header door type. wall 17 studs 4. Check mounting location for strength. Header bracket must be attached to garage door opening framework of garage. Fig. 2-5. If final header bracket position is on garage TYPICAL UNFINISHED WALL door header, continue with st
Resumo do conteúdo contido na página número 18
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM INSTALLATION 7. Attaching rail to header bracket. 5/16" Gently set power head on garage floor while FLANGE NUT leaning rail strap against header bracket. (It is recommended that you place a piece of 18 cardboard or similar material between power head and floor to prevent scrapes and scratches to power head.) NOTE: It may be necessary to support power head above floor. As little as a few inches, or as much as 5 or 6 feet depending on position o
Resumo do conteúdo contido na página número 19
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM INSTALLATION 8. Mounting power head. Raise power head and support it high enough that you can manually raise garage 19 door fully open. Line up power head and rail with center of door. Fig. 2-9. K eeping power head centered, mount to ceiling: –at proper height; a. for sectional doors rail should be level with floor or slightly below level. Fig. 2-10. b. for 1-piece doors rail should clear door by about 2 inches. Fig. 2-10. Fig. 2-9 SECTIONAL
Resumo do conteúdo contido na página número 20
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM INSTALLATION 9. Mounting door bracket [21]. WOODEN ONE-PIECE Center of bracket must be on centerline of door and must be mounted as high as top of door possible. Fig. 2-12A & B. centerline 20 Hold bracket against door at preferred location and mark screw holes. – for wooden doors, drill 5/32 inch pilot holes. a. Fasten door bracket using 3 lag screws [22]. b. Check thickness of door against lag attached board for screws. (It may be necessary