Resumo do conteúdo contido na página número 1
www.sylvane.com 1-800-934-9194
Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual
Instruction Manual
P1000/ P2000 Platinum/P3000 Onix
P1000/ P2000 Platinum/P3000 Onix
The World’s Safest and most Tested Air Purifi er
Resumo do conteúdo contido na página número 2
www.sylvane.com 1-800-934-9194 Copyright 2005 Policon Ltd. All Rights Reserved All rights reserved. No part of this publication may be reproduced, photocopied, transmitted, transcribed, stored in a retrieval system, or translated into any lan- guage in any form or by any means without the express prior written consent of Policon Ltd.
Resumo do conteúdo contido na página número 3
www.sylvane.com 1-800-934-9194 Index 2 Introduction 3 Safety Instructions 5 The invisible Enemies Applications 6 9 Airfree and Mold 10 Technical Characteristics 11 Airfree Description 12 Installing and Connecting How does Airfree work? Maintenance 14 15 Airfree’s Independent and Efficiency Tests FAQ - Frequently Asked Questions 16 20 Warranty
Resumo do conteúdo contido na página número 4
www.sylvane.com 1-800-934-9194 Congratulations for having purchased your Airfree. Airfree air purifiers are manufactured under license of US Patent 5,874,050, and many other patents pending worldwide. Airfree was designed with most advanced American and German technologies, to drastically destroy indoor airborne micro- organisms and reduce ozone. Different from other air purifier manufacturers, Airfree does not spend much time in describing fancy technologies with difficult words and theori
Resumo do conteúdo contido na página número 5
www.sylvane.com 1-800-934-9194 Safety Instructions Please read and save these instruction This applicance has a polarized plug (one blade is wider than the other). To reduce the risk of eletric shock, this plug is internaded to fi t in a polarized outlet only one way. If the plug does not fi t fully in the outlet, reverse the plug. If it still does not fi t, contact a qualifi ed electrician. Do not attempt to defeat this safety feature. Before plugging in Airfree slightly shake it to check for
Resumo do conteúdo contido na página número 6
www.sylvane.com 1-800-934-9194 Safety Instructions Always keep Airfree in its vertical position as shown in the picture. Do not attempt to use it sideways, under furniture, or with its bottom air inlets and or outlets blocked avoiding air to flow in and sterilized air to flow out ™ Airfree. If any of the above occurs, the TSS ceramic core will be discon- nected as the unit will not work properly in those conditions and after about 1 minute, the anti-stress light will start blinking to call for
Resumo do conteúdo contido na página número 7
www.sylvane.com 1-800-934-9194 The Invisible Enemies Most people spend around 90% of their time time indoors, at home or in the of- fice. The EPA – Environmental Protection Agency claims the quality of air indoors can be 100 times worse than outdoors. Some factors contribute to indoor contamination: - High concentration of people in rooms increase fungus, bacteria and vi- rus development, and cross contamination - New building insulation techniques reduce outside air interchanges and consequ
Resumo do conteúdo contido na página número 8
www.sylvane.com 1-800-934-9194 Applications Healthy rooms with pure clean air The efficient and noiseless Airfree technology safely destroys mold spores, bacteria, viruses and other airborne organic microorganisms. Respiratory allergies and Asthma Airfree drastically reduces airborne organic allergens and ozone, provid- ing cleaner and safer environment for allergic people. Airfree destroys mold spores, bacteria, viruses, dust mite allergens, pet dander and re- duces ozone, all kept to minimum
Resumo do conteúdo contido na página número 9
www.sylvane.com 1-800-934-9194 Applications Offices, Public Buildings Populated rooms, corridors, and elevators offer a constant contamination risk to employees and guests. This situation is aggravated by the flow of hazardous fungi and other microbes entering through the A/C system, and the ozone generated by computers and photocopiers. The spread of air- borne transmittable diseases can accelerate in this environment. Airfree is a powerful weapon in the reduction of airborne contamination by
Resumo do conteúdo contido na página número 10
www.sylvane.com 1-800-934-9194 Applications Pollens Pollens are no exception and like other microorganims are totally destroyed when passing through Airfree patented sterilizing core. After being incinerated the resulting harmless particles are released back to the environment. Ozone (O3) Ozone is a very toxic gas that according to EPA can damage lung tissue, cause chest pain, throat irritation and trigger asthma. The FDA, the US Food and Drug Administration, recommends not to use any equip
Resumo do conteúdo contido na página número 11
www.sylvane.com 1-800-934-9194 Airfree and Mold Guide for Airfree installation in mold contaminated rooms 1 - Install your Airfree unit in accordance with the user manual 2 - Allow your unit to run for at least one week to achieve significant airborne mold spore reduction. 3 - Clean mold infected items and surfaces, since they are a continu- ous source of new spores. It is important to stress that Airfree will not destroy or remove mold from an infected item or surface. Those surfaces must be
Resumo do conteúdo contido na página número 12
www.sylvane.com 1-800-934-9194 Technical Characteristics Model P1000 P2000 Platinum P3000 Onix 2 2 2 Capacity 450 sq ft. (42m ) 550 sq. ft (51m ) 650 sq. ft (61m ) Inside Temperature 400°F (204°C) 400°F (204°C) 400°F (204°C) Electric 45W 48W 52W Consumption Voltage 110V - 240V 110V - 240V 110V - 240V Noise Totally Silent Totally Silent Totally Silent Weight 3.1 lbs (1,43 Kg) 3.2 lbs (1,45 Kg) 3.3 lbs (1,48 Kg) height: 10.4in height: 10.4in height: 10.4in (26.5 cm) (26.5 cm) (26.5 cm) Dimensio
Resumo do conteúdo contido na página número 13
www.sylvane.com 1-800-934-9194 Airfree Description 1 1- Top Lid with Air outlets and Anti-Stress Light 2- Side Shells 2 3- On/Off Led 3 4 4- Base 5- Air Inlets 6- Power Cord 7- Anti-Stress Light 5 Dimmer 6 7 The Airfree’s anti-stress light has a esthetic effect and may be relaxing. It is pos- sible to adjust the light intensity using the dimmer at Airfree’s base. The light does not intervene or has any relation with Airfree’s patented sterilization core functioning. 11
Resumo do conteúdo contido na página número 14
www.sylvane.com 1-800-934-9194 Installing and Connecting Plug power cord to the nearest outlet. Make sure the surface is dry (never place Airfree on wet floor or immerge in water) Make sure side blue led is on. Switch on dimmer and the anti-stress light should glow from the top lid (1). After 10 minutes the top lid should be warm. Place Airfree on the floor. Do not install it under furniture or shelves, behind curtains as it will reduce air flow and Airfree efficiency in reducing microorganisms
Resumo do conteúdo contido na página número 15
www.sylvane.com 1-800-934-9194 Installing and Connecting Airfree can only be used in rooms with minimum air volume of 330 cu. ft. (10 m3), free of obstacles. Airfree can be installed in rooms equipped with air conditioning and heating systems. However it is recommended not to place Airfree nearby them to avoid potential interference in Airfree air flow. Do not place Airfree in the corridor to try to reach the whole house. In this case Airfree will only reduce air pollution in the corridor a
Resumo do conteúdo contido na página número 16
www.sylvane.com 1-800-934-9194 How does Airfree Work? Maintenance Purifi ed Air Cooling Chamber Cold and clean air is delivered to the environment without signifi cant change in room temperature and humidity. Sterilizing Ceramic Core Inside the ceramic core 99.99% of all microorganims are incinerated and eliminated from the environment Air Inlets Contaminated air enters Airfree by air convection Contaminated Air How Airfree works? Contaminated air silently enters Airfree by
Resumo do conteúdo contido na página número 17
www.sylvane.com 1-800-934-9194 Airfree Independent and Efficiency Tests AIRFREE EFFICIENCY TESTS BY INDEPENDENT LABORATORIES, INSTITUTES AND UNIVERSITIES IN FOLLOWING COUNTRIES. Reduction of Microorganisms Laboratory Local Dust Mite alergens Fungus Bacteria DerP-1 Insect R&D Limited Cambridge, UK Laboratory 70,6% to 97,95% june, 2005 SGS Natec Institute* Hamburgo/Germany Laboratory Office 99% 99% september to november, 2000 Technical Micronics Control Huntesville/USA Laboratory 93
Resumo do conteúdo contido na página número 18
www.sylvane.com 1-800-934-9194 FAQ - Frequently Asked Questions 1. How does Airfree work? Airfree incinerates microorganisms at its heated capillaries. Contaminated air is dragged into Airfree’s ceramic core by air convection and microorganisms are destroyed at high temperatures regardless of how resistant and dangerous they might be. 2. Are there any side effects? No. Airfree’s new technology uses heat to purify the air. No side effects, no emissions, NO IONS, nor new particles are gener
Resumo do conteúdo contido na página número 19
www.sylvane.com 1-800-934-9194 FAQ - Frequently Asked Questions 7. Can I use Airfree in air conditioned rooms? Yes. 8. How do I know if Airfree is no longer working? Check the top lid, if warm Airfree is working. 9. Can I place Airfree at the corridor to reach the whole house? No. Airfree will just reduce air pollution in the corridor’s area. 10. Can I place Airfree in a closed room? Yes. Please remember such a room must have at least 330cu.ft (10m3)*. * as a reference 330cu.ft
Resumo do conteúdo contido na página número 20
www.sylvane.com 1-800-934-9194 FAQ - Frequently Asked Questions 15. Does CADR measure the effectiveness of the Airfree? Not at all. CADR is not designed to test the Airfree technology. The AHAM seal (usually found on the back of an air cleaner’s box) lists three Clean Air Delivery Rate (CADR) numbers: one for tobacco smoke, one for pollen and one for dust. The CADR indicates volume of fi ltered air delivered by an air cleaner. The higher the tobacco smoke, pollen and dust numbers, the faster