Resumo do conteúdo contido na página número 1
INSTALLATION/OPERATION
DX3100 Series
Digital Video Recorder
®
C695M-B (11/03)
Resumo do conteúdo contido na página número 2
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................................................................................................. 4 DESCRIPTION ..................................................................................................................................................................................................................... 5 MODELS ............................................
Resumo do conteúdo contido na página número 3
LIST OF ILLUSTRATIONS Figure Page 1 DX3100 Front and Rear Panels ......................................................................................................................................................................... 6 2 DX3108 Rear View ............................................................................................................................................................................................ 7 3 DX3116 Rear View ..................................
Resumo do conteúdo contido na página número 4
IMPORTANT SAFEGUARDS AND WARNINGS Observe the following WARNINGS before installing and using this product. 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including a
Resumo do conteúdo contido na página número 5
DESCRIPTION DX3100 digital video recorders (DVRs) combine the functions of a high-quality recorder with a multiplexer into a single unit. Both 8- and 16-channel models are available with 60, 120, or 240 GB hard drives. You can set the DX3100 to record video at either high (640 x 240) or low (352 x 240) resolution. The DX3100 software can be upgraded through the built-in floppy disk drive (FDD) or by remote download through a network connection. All units are capable of both NTSC and PAL formats.
Resumo do conteúdo contido na página número 6
115V 8-CHANNEL FRONT VIEW 8-CHANNEL REAR VIEW 16-CHANNEL FRONT VIEW 16-CHANNEL REAR VIEW 1 23 456 78 MON OUT IN 910 11 12 13 14 15 16 G1 2 3 4 G 1 2 NTSC PAL IN OUT ALARM 115V 230V LAN P/T/Z SERIAL OUT 1-8 OUT 9-16 RC Figure 1. DX3100 Front and Rear Panels 6 C695M-B (11/03)
Resumo do conteúdo contido na página número 7
115V 115V INSTALLATION DX3100 REAR PANEL CONNECTIONS The rear views of the DX3108 and DX3116 are shown in Figures 2 and 3, respectively. 1 23 4 5 6 78 MON OUT IN 12 3 4 5 6 78 G1 2 3 4G 1 2 OUT NTSC PAL IN OUT ALARM 115V 230V LAN P/T/Z SERIAL RC Figure 2. DX3108 Rear View 1 23 4 5 6 78 MON OUT IN 910 11 121314 15 16 G1 2 3 4G 1 2 NTSC PAL IN OUT ALARM 115V 230V LAN P/T/Z SERIAL OUT1-8 OUT9-16 RC
Figure 3. DX3116 Rear View Channel inputs: 16 for DX311
Resumo do conteúdo contido na página número 8
115V MOUNT THE DX3100 Mount the controller on a flat surface (attach rubber feet if mounting on a flat surface) or use the provided rack ears to rack-mount the unit. All models occupy two rack units (RU) of rack space. One RU equals 1.75 inches or 4.45 cm. CONNECT EQUIPMENT Use the following instructions to attach all equipment to be used with the recorder. Use Figure 4 as a visual guide for connecting various types of equipment. MONITOR CAMERA INPUTS (1-16) ALARM (SENSOR) INPUTS (4) ALARM (RELA
Resumo do conteúdo contido na página número 9
CHANNELS AND MONITOR Refer to Table A for video coaxial cable distances. 1. Connect video cables to the inputs on the rear of the unit. 2. If looping is desired, attach BNC monitor cables to the appropriate output BNCs (DX3108 models) or use the provided looping output cables (DX3116 models). 3. Attach a monitor to the MON OUT BNC on the rear of the unit. This is used for programming the unit and for user operation. Table A. Video Coaxial Cable Requirements Cable Type* Maximum Distance RG59/U 7
Resumo do conteúdo contido na página número 10
ALARM WIRING Up to four alarm inputs can be wired to the DX3100. You can also connect up to two external devices to the unit. When an alarm input is triggered, the unit begins alarm recording. It can also activate the external devices. Use Figure 5 as a guide for wiring the alarm inputs and relay outputs. G1234G 1 2 IN OUT ALARM WIRING PANEL LOAD:WARNINGLIGHT EXTERNALFUSE AUTODIALER EMERGENCYSIREN Figure 5. Alarm Wiring Example WARNING: The alarm relay output provides a maximum load of 1 A at
Resumo do conteúdo contido na página número 11
CONNECT POWER NOTE: The DX3100 is set at the factory to operate on 115 VAC. For 230 VAC operation, move the voltage selection slide switch (located below the power input cord connector) to the 230 VAC position. After attaching your equipment to the rear panel connectors, connect the power cable to the unit. The unit powers up automatically. NOTE: The unit defaults to LIVE VIEW mode immediately after power-up. POWER CYCLING AND SCAN MODE OPERATION The DX3100 enters SCAN mode when it is powered
Resumo do conteúdo contido na página número 12
OPERATING AND PROGRAMMING CONTROLS The DX3100 can be operated and programmed either from the front panel of the unit or from the IR (infrared) remote controller. NOTE: Each DX3100 has its own identification number or ID. This ID can be changed on the RECORDER SETUP screen on the unit. If you change the ID on the DX3100, you must enter the new ID on the IR remote controller (refer to DX3100-IR Remote Synchronization for more information). Many controls on both the front panel and the IR remote c
Resumo do conteúdo contido na página número 13
DX3100 FRONT PANEL CONTROLS General Power switch (startup and shutdown) Toggle on-screen display (OSD) Sequence Activate multi-screen views: for 1x1, for 2x2, for 3x3, for 4x4 Display selected channel (1-8 or 1-16) Setup Enter and exit setup mode; exit submenus NOTE: The default password is 1981. Select submenu or edit field Field selection and edit: , , , Edit password (DX3116): buttons 1-9 = numbers 1-9, button 10 = 0 Edit password (DX3108): buttons 1-8 = num
Resumo do conteúdo contido na página número 14
FOCUS NEAR FOCUS NEAR FOCUS NEAR FOCUS NEAR IR REMOTE CONTROLLER CONTROLS IRIS RETURN ENTER General ZOOM IN ZOOM OUT Power switch (startup and shutdown) P/T/Z OSD SEQ Toggle on-screen display (OSD) 1 2 3 Sequence 4 5 6 7 8 9 Display selected channel full screen 0 Step through multi-screen views: 1x1, 2x2, 3x3, 4x4 PLAYBACK EVENT SETUP DAY HOUR MIN PELCODX3100 IR-REMOTE Setup IRIS RETURN ENTER ZOOM IN Enter and exit setup mode; exit submenus ZOOM OUT NOTE: The default p
Resumo do conteúdo contido na página número 15
PROGRAMMING MENU STRUCTURE All programming operations are performed in SETUP mode. Use either the DX3100 front panel buttons or the IR remote controller to program the unit. The programming menu tree is shown in Figure 7. RECORDER SETUP IMAGE SIZE [352X240][640X240] PELCO DX3100 RECORDER IMAGE RATE 16 ips (1-30) RECORDER SETUP PAGE SEQUENCE [ON][OFF] CAMERA SETUP DWELL 5 sec (1-60) ALARM SETUP PASSWORD [EDIT][CREATE] TIME/DATE SET SAT, 04/22/2002 NETWORK SETUP AM 10:00:00 SYSTEM STATUS & UPGRADE
Resumo do conteúdo contido na página número 16
SETUP MENU NAVIGATION The DX3100 has four operating modes: LIVE VIEW, SETUP, PLAYBACK, and PTZ. LIVE VIEW, which is the default mode upon power-up, is “home base” for the other three modes. NOTE: When programming the DX3100, use either the DX3100 front panel controls or the IR remote controller. To access the DX3100 setup menu: 1. Make sure the unit is in LIVE VIEW mode. If not, exit the current mode. 2. Press the SETUP button. The unit asks for the security password. NOTE: The default passwor
Resumo do conteúdo contido na página número 17
Navigating specific setup menu screens is actually quite simple. The following five steps describe how to navigate the CAMERA SETUP menu shown in Figure 9. 1. CH1 is selected. The information in the right window applies to CH1. To select a different channel, use the up and down arrow buttons. 2. Press the ENTER button to access the CH1 setting fields. The currently selected field has a darker background. Use the up and down arrow buttons to select a different field. NOTE: On the IR remote contr
Resumo do conteúdo contido na página número 18
DX3100-IR REMOTE SYNCHRONIZATION If your IR remote controller does not work with a specific DX3100, perform the following: 1. Obtain the IR remote identification number for the DX3100 from your administrator, or, if you can access SETUP mode on the DX3100, open the RECORDER SETUP screen and note the IR REMOTE ID (refer to Figure 12). It will be a number between 00 and 99. 2. Press the - and + buttons on the IR remote controller simultaneously. These buttons are located on the left and right side
Resumo do conteúdo contido na página número 19
STORAGE CALCULATIONS Due to the nature of digital video recording, the particular capabilities of the DX3100, and the different parameters for each installation, it is very difficult to calculate storage capacity. Desired image size, record rate, image quality, and number of channels are only a few of the variables that affect capacity. Before configuring the DX3100, work through this section to identify the desired settings for the DX3100 as well as all channels that are connected to it. This s
Resumo do conteúdo contido na página número 20
Average Image Size in KB (IMAGE SIZE) File size affects how long you can record for a given time period. The greater the file size, the faster you will use available hard disk space. The resolution setting reflects the size of the recorded display and thus the KB size per image. For 352 x 240, the average file size is 3KB to 5KB. A 640 x 240 choice results in a 4KB to 8KB average file size. These resolution settings only affect the image size, not the image quality. Actual image size can vary wi