Resumo do conteúdo contido na página número 1
12843 Foothill Blvd.,
Suite D
Sylmar, CA 91342
818 898 3380 voice
818 898 3360 fax
www.dnfcontrols.com
Model No. 4000CL-MAV-PBIO
(&4000CL-MAV-T-PBIO)
250 CLIP FAST ACCESS SYSTEM
with Peripheral Bus Interface Option
Sony DP Protocol
for SONY MAV-555 Video Servers
NOTE: Supports up to 4 Video Server Channels
USER MANUAL
1 4000CL-MAV, 250 Clip Fast Access System, for Sony MAV-555, with PBIO option
Resumo do conteúdo contido na página número 2
Table of Contents 1. REVISION HISTORY 3 GETTING STARTED . . . 4 2. SYSTEM DESCRIPTION 4 FEATURES 4 DEFINITIONS 4 1. SYSTEM INSTALLATION 5 a. ST300-S/SM, VTR/DDR CONTROLLER 5 b. PRODUCTION SWITCHER 5 2. VIDEO SERVER SETUP 7 3. LOAD A CLIP 7 4. LEARN ON THE ST300 7 7. LEARN ON THE PRODUCTION SWITCHER 8 8. RECALL ON THE ST300 8 9. RECALL ON THE PRODUCTION SWITCHER 8 10. PBIO ENABLE/DISABLE 9 11. TRIGGERS FROM THE PRODUCTION SWITCHER 9 ADVANCED FEATURES . . . 10 11. CREATE NEW CL
Resumo do conteúdo contido na página número 3
1. REVISION HISTORY 120602 Rev. 3.0 Added GPI’s 040303 Rev. 3.1 Added Key Layout 100903 Rev. 3.2 Company header information revised. 112503 Rev. 3.3 Updated Transmit Cue List Function and Receive Cue List Function description. Changed Key Layout. Added DNF Controls Limited Warranty. 121003 Rev. 3.4 Added LOOP A CLIP Section. Revised TRIM CLIPS Section. Added Video Sync, Video Standard, Recall Menu Options. 020504 Rev. 3.5 Added note to cover: Sup
Resumo do conteúdo contido na página número 4
Getting Started . . . 2. SYSTEM DESCRIPTION NOW, production switchers can load & play video clips on Sony MAV DDRs. Use the EMEM or SNAPSHOT Learn & Recall functions of the production switcher to load and play a video clip from a Recall or timeline. Use the Run and Trigger functions of the production switcher to Play, Stop or Recue the video clip. Instantly load a video clip at the press of a button. Instantly load a FILL clip & KEY clip at the press of ONE button, the
Resumo do conteúdo contido na página número 5
1. SYSTEM INSTALLATION a. ST300-S/SM, VTR/DDR CONTROLLER 1) Plug one end of a 9-conductor, RS422 serial cable into the 9-pin connector (VTR 1, 2, 3 or 4) on the rear of the ST300. Plug the other end of the cable into the 9-pin REMOTE connector on the Video Server. 2) Connect the +5, +12, -12 VDC POWER SUPPLY into the POWER connector on the rear of the ST300. Plug the Power Supply into an outlet, 90 VAC to 240 VAC. 3) Check SETUP MENU prior to using the ST300 to confirm pro
Resumo do conteúdo contido na página número 6
CONNECTION DIAGRAM 6 4000CL-MAV, 250 Clip Fast Access System, for Sony MAV-555, with PBIO option
Resumo do conteúdo contido na página número 7
2. VIDEO SERVER SETUP a. The SONY MAV unit must have the following or higher software versions: V1.1 b. Clips loaded from the front panel of the MAV will not be displayed on the ST300. c. SETUP MENU/RECORD MODE. Crash and Lockout are the only modes supported. 3. LOAD A CLIP a. Select VTR. Connection must be to the Player port in order to load existing clips. b. Press [CLIP LIST]. The CLIP LIST indicator will turn on. The display prompts: “WHEEL-scroll files, ENTER-ent
Resumo do conteúdo contido na página número 8
7. LEARN ON THE PRODUCTION SWITCHER a. Select and enable the Peripheral Device Addresses for the ST300. b. Do a LEARN to the desired REGISTER. The ST300 will: LEARN (save) the VTR#, loaded CLIP ID and current IN time to the REGISTER number in the ST300. 8. RECALL ON THE ST300 a. Select the desired Cue Point by pressing [NEXT CUE], [LAST CUE]. OR By manually entering the Cue Point using the numeric keypad. The selected Cue Point number is shown on the bottom line
Resumo do conteúdo contido na página número 9
10. PBIO ENABLE/DISABLE On the ST300, press the [PBIO] key to enable or disable PBIO. When disabled, the ST300 will ignore all Pbus commands. When enabled, the ST300 will respond to all Pbus commands. When enabled and Pbus commands are received, the key's LED will flash. 11. TRIGGERS FROM THE PRODUCTION SWITCHER Firing a trigger, using either the Timeline or Run function on the production switcher, causes the ST300 to put the Video Server into the following modes, based upon th
Resumo do conteúdo contido na página número 10
Advanced Features . . . 11. CREATE NEW CLIPS NOTE: Record duration must be set BEFORE creating a new clip. a. Press [SHIFT] + [RECORD]. The first line of the display shows current record duration. The second line of the display prompts “Enter record length.” b. Enter the desired record length using numeric keypad. d. Press [ENTER] to save the entered time and exit. OR Press [ESC] to exit without saving. NOTE: Default record duration is 30 minutes. d. Select
Resumo do conteúdo contido na página número 11
13. SETTING THE IN (OUT) POINT a. MARKING THE IN (OUT) POINT 1) Press [IN] ([OUT]). The IN (OUT) indicator turns on. The display shows: “IN (OUT) xx:xx:xx:xx,” where xx:xx:xx:xx is the saved time. OR Press [SHIFT] + [IN] ([OUT]) to manually enter a new IN (OUT) time. 2) Press [ENTER] to save the entered time. OR Press [ESC] to exit without saving. NOTE: When manually entering IN and OUT points, they are always marked based on tape time, not LTC, no matter what time
Resumo do conteúdo contido na página número 12
15. VIEW CONTENTS OF CUE POINT a. Use [NEXT CUE] or [LAST CUE] to access Cue Point. Contents loaded at this Cue Point (CLIP ID) will be displayed. OR b. Use numeric keypad to enter Cue Point number. Press [ENTER]. Contents are displayed. 16. TRANSFERRING CUELIST a. TRANSMIT CUE LIST FUNCTION The TRANSMIT CUELIST function allows you to transmit your list of Cue Points to a PC, using the provided utility software on the PC, or to another ST300. Transfer to a PC requires
Resumo do conteúdo contido na página número 13
b. RECEIVE CUELIST FUNCTION The RECEIVE CUELIST function allows you to receive your list of Cue Points from a PC or from another ST300. Transfer to a PC requires OpSuite 3.0 software, which runs on a Windows-based computer. Contact DNF Controls for more information. 1) TO RECEIVE CUE POINTS FROM THE ST300 a) Connect the VTR4 connector on the back of the ST300 from the VTR4 connector of the transmitting ST300 using RS422 9-pin cable with TX and RX lines crossed. (A “Turnaround”
Resumo do conteúdo contido na página número 14
Reference . . . 17. SETUP MENU Press [MENU]. The MENU indicator will turn on. Turn the Wheel to select item to change. Press [MENU] OR use the Softkeys to change the desired mode for that option. Turn the Wheel at anytime to select another item. Press [ESC] at anytime to exit SETUP MENU. The MENU indicator will turn off. MENU MODES (Turning Wheel Clockwise) RECORD Press [MENU] to select the desired record mode: Lockout, Crash (Full). WIND MODE Press Softkey to select
Resumo do conteúdo contido na página número 15
ST300 SETUP ST300 SETUP Clear Cues SetDefault Press Softkey beneath ClearCues to clear all Cue Points to 00:00:00:00. Press Softkey [YES] when asked “Are You Sure?” Press Softkey beneath SetDefault to set ST300 to default settings. Press Softkey [YES] when asked “Are You Sure?” DISPLAY The version number for the currently installed software is displayed. SOFTWARE VERSION SYNC Set to ON if black burst is supplied to the Ref Video connector on the rear panel. Set
Resumo do conteúdo contido na página número 16
18. FUNCTION TABLE Function Key Press Description GOTO ENTERED [SHIFT] + [RECUE] Search the VTR to the manually entered time. TIME Use the ST300 numeric keypad. Press [ENTER] or [RECUE]. FFWD [FFWD] Press and HOLD to shuttle. Release key to stop. Set WIND Speed in MENU. JOG [JOG] Select JOG mode and enable Wheel. LAST CUE [LAST CUE] Step to the previous Cue Point Location. NEXT CUE [NEXT CUE] Step to the next Cue Point Location. RECORD [REC] Places VTR into the Record mo
Resumo do conteúdo contido na página número 17
19. SPECIFICATIONS ST300 Power: 90 VAC to 265 VAC adapter supplied with IEC connector Size: (L” x W” x H”) 12” x 6” x 1.5” (front) 3.0” (rear) (T-bar unit is 12.6” long) Weight: 4 lbs. Rear Panel Connectors: VTR1, VTR2, VTR3, VTR4 … All DB9F GPI......................................….. DBF15F Power....................…................ DB9M Aux .............................…......… DB9F Display: Easy to read 2-line, back-lit LCD display (User adj
Resumo do conteúdo contido na página número 18
GPI IN/OUT CONNECTOR 15-Pin D-Type, Female (DB15F) Pin # Description Function Pin # Description Function 1 GPI 1 Out 9 GPI 1 In Play 2 GPI 2 Out 10 GPI 2 In Stop 3 GPI 3 Out 11 GPI 3 In Recue 4 GPI 4 Out 12 GPI 4 In Next Cue 5 GPI 5 Out 13 GPI 5 In Last Cue 6 GPI 6 Out 14 GPI 6 In Recall 7 GPI 7 Out 15 GPI 7 In 8 Ground 18 4000CL-MAV, 250 Clip Fast Access System, for Sony MAV-555, with PBIO option
Resumo do conteúdo contido na página número 19
20. KEY LAYOUT 19 4000CL-MAV, 250 Clip Fast Access System, for Sony MAV-555, with PBIO option
Resumo do conteúdo contido na página número 20
21. DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one (1) year from the date of sale to the original purchaser from DNF Controls. In order to enforce the rights under this warranty, the customer must first contact DNF’s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair. If DNF’s Customer Support Department cannot fix