Hurricane™ 1100
OK on Dimmer
F-1100
Outdoor OK
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
User Serviceable
Duty Cycle
USER MANUAL
th
3000 N 29 Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS 1. Before You Begin ................................................................................................................................ 2 What is included ....................................................................................................................................... 2 Unpacking Instructions .............................................................................................................................. 2 AC Power ...........
Resumo do conteúdo contido na página número 3
AC Power To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power
Resumo do conteúdo contido na página número 4
2. INTRODUCTION Features Output: 8,000cfm 1.3L tank capacity Uses 1L every 21min (continuous use at full output) 5 minute heat up Manual fog button Low fluid indicator and auto shut down Wired remote included Water-based fogger Product Dimensions Hurricane™ 1100 User Manual 4 3/26/2009 3:17 PM
Resumo do conteúdo contido na página número 5
Product Overview Hanging bracket Fluid container Safety cable eye bolt Tilt Adjustment knob Heater Nozzle Manual Fog Low Fluid button indicator Fluid level indicator Manual Controller Wireless Controller Power input (hardwired) Fuse holder Hurricane™ 1100 User Manual 5 3/26/2009 3:17 PM
Resumo do conteúdo contido na página número 6
Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement With a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged The fuse is located fuse from its holder and replace with exact inside this compartment. same type fuse. Insert the fuse holder back in Remove using a flat its place and reconnect power. head screwdriver. Mounting ORIENTATION This fixture should only be mounted/used on
Resumo do conteúdo contido na página número 7
5. OPERATING INSTRUCTIONS Operation This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog machine to run off bursts with adjustable interval and duration settings. Manual Remote Operation (FC-M) (Standard) 1) Plug in the fog machine to power. 2) Plug in the M remote to the Manual Controller socket on the rear of the fog machine. 3) Press the single button located on the remote to trigger the fog output. Note: The button is mom
Resumo do conteúdo contido na página número 8
Wireless Controller (FC-W) (Optional) This mode will allow you to control the fogger using the optional wireless controller. This consists of the transmitter and the receiver. You may control up to 4 independent fog machines, or many more if you run them simultaneously. See the below instructions on setting up your fogger to operate with the FC-W. 1) Plug the wires receiver into the fog machine 5-pin port labeled “Wireless Controller”. 2) There are 4 buttons on the wireless remote transmitt
Resumo do conteúdo contido na página número 9
Hurricane™ 1100 General Troubleshooting Symptom Solution(s) No Power Check mains power. Check external fuse. Check internal fuse. No fog output Check fluid level. Check remote. If using wireless, check batteries. If using wireless, check dipswitches on receiver. Breaker/Fuse keeps blowing Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. Low fog output Run a cleaning solution through the fog machine. Check that the fog machine is plu
Resumo do conteúdo contido na página número 10
6. APPENDIX General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. Unplug fixture from power. U
Resumo do conteúdo contido na página número 11
Blow-out Diagram. 10 9 7 3 5 1 12 8 11 Description Part Number 1 Master PCB 120V P170-F1MSPCB 2 Master PCB 220V 220VP170-F1MSPCB 3 Heater 700W 550° Celsius 120V P120-HT7 4 Heater 700W 550° Celsius 220V 220VP120-HT7 5 Pump 120V P200-F1PUMP 6 Pump 220V 220VP200-F1PUMP 7 Fluid container 1.3 liters P70-F1FLC 8 Fluid sensor P170-F1FLOS 9 Thermal switch 115° Celsius P170-THEF11 10 Bracket Knob P111-F1BKNOB 11 Fuse holder P170-FUSEHOL 12 Manual fog button P111-F1FOGB 13
Resumo do conteúdo contido na página número 12
Connections Drawing In the event that any part(s) may need to be replaced/repaired, you may use the below diagram to assist in this operation. Warning: All repairs should only be performed by Authorized Service Personnel. Hurricane™ 1100 User Manual 12 3/26/2009 3:17 PM
Resumo do conteúdo contido na página número 13
Technical Specifications WEIGHT & DIMENSIONS Length ................................................................................................................................ 9.7 in (247 mm) Width .................................................................................................................................. 9.6 in (243 mm) Height ................................................................................................................................. 8.7 in (2