Resumo do conteúdo contido na página número 1
Snapshot
Hurricane™ 1300
OK on Dimmer
F-1300
Outdoor OK
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
User Serviceable
Duty Cycle
USER MANUAL
th
3000 N 29 Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS 1. Before You Begin .................................................................................................................................................................. 3 What is included .......................................................................................................................................................................... 3 Unpacking Instructions .................................................................................
Resumo do conteúdo contido na página número 3
1. BEFORE YOU BEGIN What is included 1 x Hurricane™ 1300 1 x FC-T wired timer remote 1 x Warranty Card 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the
Resumo do conteúdo contido na página número 4
Safety Instructions Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product. Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel o
Resumo do conteúdo contido na página número 5
2. INTRODUCTION Features Output: 20,000cfm 3.3L tank capacity Uses 1L every 8min (continuous use at full output) 5 minute heat up Manual fog button Low fluid indicator and auto shut down Wired timer remote included Water-based fogger Product Dimensions Hurricane™ 1300 User Manual 5 3/26/2009 3:18 PM
Resumo do conteúdo contido na página número 6
Product Overview Hanging bracket Safety eyebolt Fluid container Handle Tilt Heater Adjustment Nozzle knob Low Fluid indicator Manual Fluid level controller Power indicator switch Fuse holder Power input (hardwired) Manual Fog Wireless button Controller Hurricane™ 1300 User Manual 6 3/26/2009 3:18 PM
Resumo do conteúdo contido na página número 7
Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement With a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged The fuse is located fuse from its holder and replace with exact inside this same type fuse. Insert the fuse holder back in compartment. Remove using a flat its place and reconnect power. head screwdriver. Mounting ORIENTATION This fixture should only be mounted/used on a
Resumo do conteúdo contido na página número 8
3. OPERATING INSTRUCTIONS Operation Manual Remote Operation (FC-M) (Optional) 1. Plug in the fog machine to power and turn the power switch to the fixture on. 2. Plug in the wired manual remote to the Manual Controller socket on the rear of the fog machine. 3. Press the single button located on the remote to trigger the fog output. Note: The button is momentary, which means that the fog machine will only output while the button is pressed. Once the button is released, the fog will stop ou
Resumo do conteúdo contido na página número 9
Wireless Controller (FC-W) (Optional) This mode will allow you to control the fogger using the optional wireless controller. This consists of the transmitter and the receiver. You may control up to 4 independent fog machines or many more if you run them simultaneously. See the below instructions on setting up your fogger to operate with the FC-W. 1. Plug the wires receiver into the fog machine 5-pin port labeled “Wireless Controller”. 2. There are 4 buttons on the wireless remote transmitte
Resumo do conteúdo contido na página número 10
Hurricane™ 1300 General Troubleshooting Symptom Solution(s) No Power Check mains power. Check external fuse. Check internal fuse. No fog output Check fluid level. Check remote. If using wireless, check batteries. If using wireless, check dipswitches on receiver. Breaker/Fuse keeps Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for blowing further instruction. Low fog output Run a cleaning solution through the fog machine. Check that the fog machine is plu
Resumo do conteúdo contido na página número 11
4. APPENDIX General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. Unplug fixture from power. U
Resumo do conteúdo contido na página número 12
Blow-out Diagram. 7 6 2 3 1 4 8 9 Description Part Number 1 Master PCB P170-F3MSPCB 2 Heater P120-HT13 3 Pump P200-F3PUMP 4 Fluid container P170-F3FLC 5 Fluid sensor (not shown) P170-F1FLOS 6 Thermal switch 115° Celsius P170-THEF11 7 Bracket Knob P111-F3BKNOB 8 Fuse holder P170-FUSEHOL 9 Manual fog button P111-F3FOGB 10 Fuse 13A 250V (not shown) P170-FUSE013 11 Fluid filter (not shown) P110-F1FLAS 12 Fluid hose with fittings (not shown) P170-F3RUB 13 Copper tu
Resumo do conteúdo contido na página número 13
Connections Drawing In the event that any part(s) may need to be replaced/repaired, you may use the below diagram to assist in this operation. Warning: All repairs should only be performed by Authorized Service Personnel. Hurricane™ 1300 User Manual 13 3/26/2009 3:18 PM
Resumo do conteúdo contido na página número 14
Technical Specifications WEIGHT & DIMENSIONS Length .............................................................................................................................. 16.5 in (419 mm) Width ................................................................................................................................ 12.3 in (313 mm) Height ............................................................................................................................... 12.1 in (306