Resumo do conteúdo contido na página número 1
Installation, Service and User Instructions
Built-in gas cooktops
BERTAZZONI
DIMENSIONS: 36’’ (915 mm)(W) x 253/16’’ (640 mm)(D)
Models C36500X (Z36500X) [C3W0..U4X(2 or 5)A]
Models C36600X (Z36600X) [C3Y0..U4X(2 or 5)A]
IMPORTANT - PLEASE READ AND FOLLOW
-Before beginning installation, please read these instructions completely and carefully.
-Do not remove permanently affixed labels, warnings, or plates from the product. This may void the wa
Resumo do conteúdo contido na página número 2
WARNING Read this instruction booklet before installing and using the appliance. The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance. The manufacturer reserves the right to make changes to its products when considered necessary and useful, without affecting the essential safety and operating characteristics. This appliance has been designed for non-professional, domestic use only. Warning: do n
Resumo do conteúdo contido na página número 3
INSTALLATION MANUAL BACKGUARD INSTALLATION INSTRUCTION Please follow the following installation instructions afther installing the cooktop: 1) Remove n°2 screws fixing worktop as shown in fig.1 2) Place front part of the backguard and attach it from bottom side with the two removed screws (point 2) as shown in fig .2 3) Fix the front part of the backguard with the screws supplied with the backguard kit (fig.3) 4) Assemble back part with front part of backguard and fix them with a screw s
Resumo do conteúdo contido na página número 4
PROXIMITY TO SIDE CABINET INSTALLATION 1. This rangetop may be installed directly adjacent to existing 36" (91.5 cm) high base cabinets. IMPORTANT: The top grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertOP. 2.The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36" (91.5 cm) high. There must be a minimum of 6" (15.2 cm) side clearance from the rangetop to such combustible surfaces
Resumo do conteúdo contido na página número 5
COOKER HOOD INSTALLATION The bottom of the hood should be 25 ½ " (65 cm) min. to 31 ½ " (80 cm) above the countertop. Refer to the rangehood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. ELECTRICAL CONNECTION This unit is manufactured for a polarized, grounded 120 volt/60 Hz, 16 amp system. Electric power consumption is about 1 W. The minimum of 102 VAC is required for proper operation of gas ignition systems. Th
Resumo do conteúdo contido na página número 6
Wiring diagram For freestanding gas range model C36600X (Z36 6 00 X) C3Y0..U4X(2 or 5)A CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. For freestanding gas range model C36500X (Z36 5 00 X) C3W0..U4X(2 or 5)A CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation
Resumo do conteúdo contido na página número 7
Resumo do conteúdo contido na página número 8
REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the appliance. Replacement parts are available from factory authorized parts distributors. CONVERSIONE TO DIFFERENT TYPES OF GAS Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig. Adaptation of the pressure regulator for use with different type of gas The pressure regulator supplied with the appl
Resumo do conteúdo contido na página número 9
Models C36600X (Z36 6 00 X) [C3Y0..U4X(2 or 5)A] Adapting to different types of gas Burner Position Injector Gas Pressure Max Rate Min Rate By-pass diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm] Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated 0,54 LP (Propane) 11” 3400 996 900 264 0,29 Semi-Rapid Rear L & C 1,18 NG 4” 6100 1787 1500 439 Regulated Front C 0,70 LP (Propane) 11” 6100 17871500 439 0,36 Rapid Rear L 1,55 NG 4” 10400 30472500 732 Regulated 0,92
Resumo do conteúdo contido na página número 10
SERVICE & MAINTENANCE INSTRUCTIONS Service and maintenance only to be carried out by an authorised person To replace parts such as burners, valves and electric components, the appliance must be open removing the worktop. Note: if the valves must be replaced, first disassemble the ignitions switches wires. It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal between the body and the gas train. WARNING: After first installation of the a
Resumo do conteúdo contido na página número 11
USING BURNERS A diagram is etched on the control panel above each knob which indicates which burner corresponds to that knob. Manual ignition: Manual ignition is always possible even when the power is cut off or in the event of prolonged power failure. Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star (large flame) and place a lit match up to the burner. Automatic electric ignition: Turn the knob that corresponds to the burner s
Resumo do conteúdo contido na página número 12
CLEANING THE APPLIANCE: Never use abrasive cleaners Before cleaning the appliance it should be disconnected from the power supply. Cleaning the work surface: periodically clean the burner heads, the cast iron pan supports and the burner caps using warm water. Any spillage must always be removed as soon as possible using a rag. If it become difficult to open or close a valve, do not force it, but immediately request the assistance of the technical service personnel. Cleaning the enamelled
Resumo do conteúdo contido na página número 13
SPARE PART LIST Quantity Number Drawing Code Description 1 601739 CIRCUIT DIAGRAM 1 1 11 202317 PART FOR BURNER FIXING 3 3 11 202386 PART FOR DUAL WOK AND SEMI RAPID BURNERS 1 1 13 510507 SMALL BURNER 1 1 13 510508 SEMI RAPID BURNER 1 3 13 510509 RAPID BURNER 1 1 13 510511 DUAL BURNER 1 1 14 504128 SMALL FLAME SPREADER 1 1 14 504129 MEDIUM FLAME SPREADER 2 3 14 504130 RAPID FLAME SPREADER 1 1 14 504189 ULTRA RAPID FLAME SPREADER 1 1 15 504160 COVER FOR SMALL FLAME SPREADE
Resumo do conteúdo contido na página número 14
1631 501647 TUBE FOR RIGHT BACK BURNER 1 1 1800 501652 REAR CENTRAL TUBE 1 1801 501648 TUBE FOR LEFT BACK BURNER 1 1 1802 501653 FRONT CENTRAL TUBE 1 1803 501655 TUBE FOR EXTERNAL DUAL BURNER 1 1804 501654 TUBE FOR INTERNLA DUAL BURNER 1 1805 501650 CENTRAL TUBE 1 1806 501651 EXTERNAL CENTRAL TUBE 1 1807 501649 TUBE FOR FRONT LEFT BURNER 1 14
Resumo do conteúdo contido na página número 15
15