Streszczenie treści zawartej na stronie nr. 1
SERVICE MANUAL
(DOMESTIC)
IMPINGER CONVEYOR OVENS
MODEL
1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1,
1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1,
1132-080-A, 1132-080-A1, 1133-080-A, 1132-080-A1,
1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A,
1161-080-A, 1162-080-A
WITH PUSH BUTTON CONTROLS
Lincoln Foodservice Products, LLC
1111 North Hadley Road
Fort Wayne, Indiana 46804
United States of America
Phone : (800) 374-3004
U.S. Fax: (888) 790-8193 •
Streszczenie treści zawartej na stronie nr. 2
SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, GAS (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A LP GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A1 LP GAS 120VAC 60 HZ. 1 PHASE POWER SUPPLY Electrical power is supplied to the oven by a three-conductor cordset. Voltage from the black conductor to the white conductor is 120VAC. Black conductor is hot White conductor is neutral. Green
Streszczenie treści zawartej na stronie nr. 3
SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, ELECTRIC (OVENS WITH PUSH BUTTON CONTROLS) 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240VAC 60 HZ. 1 PHASE 1131-080-A1 120/240VAC 60 HZ. 1 PHASE 1131-08H-A 240 VAC 60 HZ. 1 PHASE 1132-080-A 120/208VAC 60 HZ. 3 PHASE 1132-080-A1 120/208VAC 60 HZ. 3 PHASE 1132-08H-A 208 VAC 60 HZ. 3 PHASE 1133-080-A 120/240VAC 60 HZ. 3 PHASE 1133-080-A1
Streszczenie treści zawartej na stronie nr. 4
SCHEMATIC DIAGRAM MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 4 Impinger II – Advantage Digital Express Service Manual - Domestic
Streszczenie treści zawartej na stronie nr. 5
SCHEMATIC DIAGRAM MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1 SCHEMATIC DIAGRAM Impinger II – Advantage Digital Express Service Manual - Domestic 5
Streszczenie treści zawartej na stronie nr. 6
MODEL 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1 6 Impinger II – Advantage Digital Express Service Manual - Domestic
Streszczenie treści zawartej na stronie nr. 7
SCHEMATIC DIAGRAM MODEL 1161-080-A Impinger II – Advantage Digital Express Service Manual - Domestic 7
Streszczenie treści zawartej na stronie nr. 8
SCHEMATIC DIAGRAM MODEL 1162-080-A 8 Impinger II – Advantage Digital Express Service Manual - Domestic
Streszczenie treści zawartej na stronie nr. 9
SCHEMATIC DIAGRAM MODEL 1130-08H-A, 1131-08H-A Impinger II – Advantage Digital Express Service Manual - Domestic 9
Streszczenie treści zawartej na stronie nr. 10
SCHEMATIC DIAGRAM MODEL 1132-08H-A, 1133-08H-A 10 Impinger II – Advantage Digital Express Service Manual - Domestic
Streszczenie treści zawartej na stronie nr. 11
TROUBLESHOOTING GUIDE GAS OVENS MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. MODEL 1117-080-A LP GAS 120VAC 60 HZ. MODEL 1117-080-A1 LP GAS 120VAC 60 HZ. SYMPTOM POSSIBLE CAUSE EVALUATION Oven fan will not run Incoming power supply Check circuit breakers, reset if required. Check power plug to be sure it is firmly in receptacle. Measure incoming power, call power co. if needed. Fuse, 10 Amp Check, replace if necessary. Fuse holder Check, r
Streszczenie treści zawartej na stronie nr. 12
the main fan motor) to neutral. If no voltage is present, trace wiring back to the main power switch. If voltage is present, check for 120VAC at wire #22 (output of centrifugal switch) to neutral. If no voltage is present at #22, and the motor is running, replace the main fan motor. Hi-limit thermostat, Terminals are normally closed. If open, reset oven cavity thermostat and retest. If thermostat will not hold for maximum oven temperature, and oven is not exceeding temperature setti
Streszczenie treści zawartej na stronie nr. 13
occur. If flame is not detected, the ignition control will shut off and lock out. To reset the ignition control, turn off the power switch for 45 seconds, then turn the switch on to re-try ignition. The ignition control requires a minimum of 0.8 DC microamps to prove flame. To check flame sensing operation, connect a digital multimeter (capable of measuring DC microamps) between the “ground” terminal on ignition control and the ground lead. NOTE: This is a current measurement and the me
Streszczenie treści zawartej na stronie nr. 14
Oven control If the thermocouple checks good, but the oven control display indicates that there is a thermocouple failure, replace the oven control. If the oven control indicates a temperature reading but the oven won’t heat, proceed. Thermocouple WITH POWER ON AND THERMOCOUPLE ATTACHED TO THE OVEN CONTROL: Measure the DC millivolt output of the thermocouple. Refer to the thermocouple chart (located in the “Removal” section of the manual) for proper millivolt readings. If these readi
Streszczenie treści zawartej na stronie nr. 15
needed. WARNING: Capacitor has a stored charge, discharge before testing. Switch, conveyor reversing Check continuity between switch terminals. Replace switch as needed. Oven control If there is 120VAC supplied to the motor, and the motor, capacitor, and reversing switch check good, replace the oven control. Conveyor motor runs, but NOTE: Display will indicate there is no speed display “Belt Jam” Oven control Check for output voltage from oven control to hall effect sensor (sens
Streszczenie treści zawartej na stronie nr. 16
1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240VAC 60 HZ. 1 PHASE 1131-080-A1 120/240VAC 60 HZ. 1 PHASE 1131-08H-A 240 VAC 60 HZ. 1 PHASE 1132-080-A 120/208VAC 60 HZ. 3 PHASE 1132-080-A1 120/208VAC 60 HZ. 3 PHASE 1132-08H-A 208 VAC 60 HZ. 3 PHASE 1133-080-A 120/240VAC 60 HZ. 3 PHASE 1133-080-A1 120/240VAC 60 HZ. 3 PHASE 1133-08H-A 240 VAC 60 HZ. 3 PHASE 1161-080-A 120/240VAC 60 HZ
Streszczenie treści zawartej na stronie nr. 17
Replace relay as needed. Main fan runs after Oven start relay Contacts should open when main power switch is 20 minute cool down turned off. Replace relay as needed. 20 Minute time delay 120VAC at terminal #2 should discontinue approx. 20 minutes after main power is switched off. If the oven start relay contacts are open, and the voltage continues at terminal #2 of the 20 minute timer, for more than 20 minutes, replace the 20 minute time delay. Oven fan relay Check to insure that the
Streszczenie treści zawartej na stronie nr. 18
If there is a read-out on the control, set the control to maximum temperature (see installation operations manual for temperature adjustment). With the control set at maximum temperature, check for supply voltage at mercury contactor. If there is voltage at the mercury contactor, proceed to “mercury contactor” for next check. If there is no voltage at the mercury contactor, trace wiring back to the oven control. If there is no voltage output at the oven control, check the read-out on th
Streszczenie treści zawartej na stronie nr. 19
thermal protection and will cease to operate if overheating occurs. As the motor overheats and then cools, this will cause the oven to cycle on and off intermittently. Improper ventilation or lack of preventive maintenance may cause this. Also, most of the problems listed under “Oven will not heat” can cause intermittent failure. Conveyor will not run Power supply Check circuit breakers, reset if required. Check power plug to be sure it is firmly in receptacle. Measure incoming power,
Streszczenie treści zawartej na stronie nr. 20
Conveyor motor If there is voltage supplied to the hall effect sensor, check for a frequency output from the hall effect sensor. Measure frequency across the yellow and white wires at the motor connector. Frequency reading should be approx. 25 – 100 Hz. If these readings are not achieved, replace conveyor motor. If the readings are achieved, proceed. Oven control If the hall effect sensor readings are correct, but there is no speed indicated on the display, replace the oven control.