Streszczenie treści zawartej na stronie nr. 1
Media Air Cleaner
INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL
Contents
How Your Media Air Cleaner Works............................................................................................................................................ 3
How You Can Maintain Your Media Air Cleaner.......................................................................................................................... 3
Read Before You Begin installing Your Media Air Cleaner..............................
Streszczenie treści zawartej na stronie nr. 2
MEDIA AIR CLEANER HOW YOUR MEDIA AIR CLEANER WORKS Thank you for purchasing a Honeywell Media Air Cleaner. 2 Your Honeywell Media Air Cleaner works by capturing small particles, such as dust and pollen, in between thousands of 1 small fibers. These fibers provide high efficiency filtration while allowing air to pass with minimal resistance. Since your heating and cooling system relies on proper air flow to operate correctly, this feature allows improved filtration without impacting the pe
Streszczenie treści zawartej na stronie nr. 3
MEDIA AIR CLEANER IMPORTANT Failure to replace the filter cartridge on a regular CAUTION basis may result in decreased system performance Sharp Edges Installation Hazard. Can cause and possible damage to HVAC components. personal injury. Wear gloves and safety glasses when handling media air cleaner or sheet metal components. READ BEFORE YOU BEGIN INSTALLING YOUR MEDIA AIR Included in the Box This box contains the following items: CLEANER: — Media Air Cleaner Cabinet and Door — CF200 Media A
Streszczenie treści zawartej na stronie nr. 4
MEDIA AIR CLEANER HOW TO INSTALL YOUR MEDIA AIR CLEANER IMPORTANT: Due to differences in how furnaces are installed, it is impossible to provide detailed instructions that cover every installa- tion. The following instructions provide general guidelines on installation of the Media Air Cleaner. It is the responsibility of the installer to determine how to properly install the Media Air Cleaner in accordance with local codes, standards, and accepted building practices. Determine Best Location f
Streszczenie treści zawartej na stronie nr. 5
MEDIA AIR CLEANER M941A Fig. 5. Highboy furnace with closet installation. Media air cleaner is mounted vertically on furnace between furnace and louvered return air opening in closet door. M943A Fig. 7. Downflow furnace with media air cleaner mounted horizontally in return duct just above furnace. M942A Fig. 6. Lowboy furnace with media air cleaner mounted horizontally in return duct just above furnace and opposite heating duct. 5 69-1866—01
Streszczenie treści zawartej na stronie nr. 6
MEDIA AIR CLEANER M944A Fig. 8. Central return installation with media air cleaner mounted horizontally in central return duct. M945A Fig. 9. Horizontal furnace with media air cleaner mounted vertically in return duct near furnace. FILTER SIZE 20 X 25 16 X 25 0.300 1 0.250 0.200 0.150 0.100 0.050 0.000 0 500 1000 1500 2000 AIRFLOW (CFM) 1 WHEN FIRST INSTALLED. PRESSURE DROP INCREASES AS FILTER BECOMES LOADED. REPLACE FILTER WHEN PRESSURE DROP REACHES 0.5 IN. WC. (0.1 kPa). M13644 Fig. 10. Press
Streszczenie treści zawartej na stronie nr. 7
MEDIA AIR CLEANER 1 1 (29) 8 DIM. B DIM. A (SEE TABLE) (SEE TABLE) 7 3 7 8 6 5 (22) 8 4 DIM. C (SEE TABLE) 8 (171) (22) (16) DIM. D (SEE TABLE) RMAC SIZE DIM. A DIM. B DIM. C DIM. D IN. MM IN. MM IN. MM IN. MM IN. MM 406 X 635 16 X 25 14 7/16 367 16 3/16 411 23 1/4 591 25 1/2 648 406 X 508 16 X 20 14 7/16 367 16 3/16 411 18 1/4 457 20 1/2 521 M13643 Fig. 11. Air cleaner dimensions. Determine Sheet-Metal Requirements The media air cleaner is adaptable to all new or existing for DUCT SIZE CHANGED
Streszczenie treści zawartej na stronie nr. 8
MEDIA AIR CLEANER 2. Turning Vanes • If the media air cleaner is installed next to an elbow TURNING or angel fitting, add turning vanes inside the angle to VANES distribute airflow more evenly across the face of the media. See Fig. 13. • Turning vanes must be properly secured to prevent movement. 3. Duct Offsets • If the duct connection to the furnace in a side installation is less than 7 in. you will need to add an offset. See Fig. 14. • Turning vanes may be required to distribute air flo
Streszczenie treści zawartej na stronie nr. 9
MEDIA AIR CLEANER Disconnect Existing Ductwork NOTE: Skip this step if the media air cleaner is being installed on a new system without existing duct that needs to be removed or modified. 1. Review the installation location and verify that there is adequate clearance for removal and replacement of the filter cartridge. See Fig. 16. 2. Make sure that all sheet-metal components, such as transitions and duct offsets, are available. 3. Carefully disconnect the existing ductwork where the air c
Streszczenie treści zawartej na stronie nr. 10
MEDIA AIR CLEANER Install Filter Cartridge 1. Slide filter cartridge into cabinet, making sure the “AIR MARK AIR FLOW DIRECTION FLOW” arrow on the cartridge is in the direction of air WITH PERMANENT flow (pointing towards furnace). MARKER 2. Record installation date in the space provided on the replacement filter cartridge. See Fig. 17. 3. Insert the tab on the bottom of the door into the slot in the cabinet. AIR FLOW Make sure the air flow is in the direction of the arrow. 4. Swing door cl
Streszczenie treści zawartej na stronie nr. 11
MEDIA AIR CLEANER Limited Warranty Honeywell warrants this product, excluding bulbs, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option) within a reasonable period of time. If the product is defective, return it, with a bill of sale or other d
Streszczenie treści zawartej na stronie nr. 12
MEDIA AIR CLEANER Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2009 Honeywell International Inc. 69-1866—01 E.K. Rev. 05-09