Streszczenie treści zawartej na stronie nr. 1 
                    
                        H8/2318 Series
FP-100B/TFP-100B  
User System Interface Cable 
(HS2318ECH61H) 
for E6000 Emulator 
User’s Manual 
 
Rev. 2.0 
4/1/03 
Renesas Technology Corp. 
 
 
HS2318ECH61HE(B)                                                                                                                                                                                                                                                                                                                                
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        Cautions  1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s  patent, copyright, trademark, or other intellectual property rights for information contained in  this document.  Renesas bears no responsibility for problems that may arise with third party’s  rights, including intellectual property rights, in connection with use of the information contained  in this document.  2. Products and product specifications may be subject to change without notice.
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        Preface  Thank you for purchasing this user system interface cable (HS2318ECH61H) for the Renesas’s  original microcomputer H8/2318 series.  The HS2318ECH61H is a user system interface cable that connects an H8/2318 series E6000  emulator (HS2338EPI61H; hereinafter referred to as the emulator) to the IC socket for a  FP-100B/TFP-100B package for the H8S/2318 series MCU on the user system.    i                                                                                                        
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        Contents    Section 1    Configuration....................................................................................1  Section 2   Connection Procedures......................................................................3  2.1 Connecting User System Interface Cable to Emulator Station .........................................3  2.2 Connecting User System Interface Cable to User System ................................................5  2.2.1 Installing IC Socket ..........................
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        Section 1    Configuration  CAUTION    Use an IC149-100-054-B51 socket (manufactured by    YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/TFP-  100B package IC socket on the user system.    Figure 1 shows the configuration of the HS2318ECH61H user system interface cable for the   FP-100B/TFP-100B package.    Figure 1   HS2318ECH61H User System Interface Cable  1                                                                                                                                       
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        Table 1 lists the HS2318ECH61H components.  Please make sure you have all of these components  when unpacking.  Table 1 HS2318ECH61H Components  No. Component Quantity Remarks  1 Cable body 1 Flat cable  2 Cable head 1    3 IC socket 1 For the FP-100B/TFP-100B package  4 Socket cover 1 For installing an FP-100B/TFP-100B-packaged  MCU  5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers)  6 Screws (M2.6 x 6 mm) 4 For installing an FP-100B/TFP-100B-packaged  MCU (with four f
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        Section 2   Connection Procedures  2.1 Connecting User System Interface Cable to Emulator Station  WARNING     Observe the precautions listed below.  Failure to do so    will result in a FIRE HAZARD and will damage the user    system and the emulator product or will result in    PERSONAL INJURY.  The USER PROGRAM will be    LOST.     1.  Always switch OFF the user system and the emulator    product before the USER SYSTEM INTERFACE CABLE     is connected to or removed from any part.  Before     c
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                          Figure 2   Connecting User System Interface Cable to Emulator Station  4                                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        2.2 Connecting User System Interface Cable to User System  WARNING     Always switch OFF the user system and the emulator    product before the USER SYSTEM INTERFACE CABLE    is connected to or removed from any part.  Before    connecting, make sure that pin 1 on both sides are correctly    aligned.  Failure to do so will result in a FIRE HAZARD and    will damage the user system and the emulator product or    will result in PERSONAL INJURY.  The USER PROGRAM will    be LOST.  To connect the cab
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        2.2.3 Inserting Cable Head  CAUTION    Check the location of pin 1 before inserting.    Align pin 1 on the IC socket for an FP-100B/TFP-100B package on the user system with pin 1 on  the user system interface cable head, and insert the user system interface cable head into the IC  socket on the user system, as shown in figure 3.   2.2.4 Fastening Cable Head  CAUTION   1. Use a Philips-type screwdriver whose head matches     the screw head.   2. The tightening torque must be 0.294 N•m or less.   
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        Fasten the user system interface cable head to the IC socket for an FP-100B/TFP-100B package on  the user system with the four screws (M2.6 x 12 mm; with four flat washers) provided.  Each screw  should be tightened a little at a time, alternating between screws on opposing corners.  Take special  care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from  being damaged by overtightening the screws or twisting the components.   Cable head User system   Fi
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        2.2.5 Fastening Cable Body  Connect the cable body to the cable head.  Cable body Removing Push the remove jigs. Remove jig Cable head User system   Figure 4   Fastening Cable Body  8                                                                                                                                                                                                                                                                                                                             
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        2.3 Recommended Dimensions for User System Mount Pad  Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with  an IC socket for an FP-100B/TFP-100B package (IC149-100-054-B51: manufactured by  YAMAICHI ELECTRONICS Co., Ltd.).  Note that the dimensions in figure 5 are somewhat  different from those of the actual chip's mount pad.  17.10 min 13.80 max 0.5  24 = 12.00 ± 0.05 0.50 ± 0.05 0.30 ± 0.05 Unit: mm   Figure 5   Recommended Dimensions for Mount Pad  
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        2.4 Dimensions for User System Interface Cable Head  The dimensions for the user system interface cable head are shown in figure 6.  29.0 16.5 63.5          Unit: mm Tolerance: ±0.5 mm   Figure 6   Dimensions for User System Interface Cable Head  10    16.0 29.0 63.5                                                                                                                                                                                                                                         
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        2.5 Resulting Dimensions after Connecting User System Interface Cable  The resulting dimensions, after connecting the user system interface cable head to the user system,  are shown in figure 7.      Figure 7   Resulting Dimensions after Connecting User System Interface Cable  11                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        Section 3   Installing the MCU to the User System  CAUTION   1. Check the location of pin 1 before inserting.   2. Use a Philips-type screwdriver whose head matches     the screw head.   3. The tightening torque must be 0.294 N•m or less.      If the applied torque cannot be accurately measured,     stop tightening when the force required to turn the screw     becomes significantly greater than that needed when first     tightening.  If a screw is tightened too much, the screw     head may break
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                          Figure 8   Installing MCU to User System  13                                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        Section 4   Verifying Operation  1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the  procedures described in the H8S Series E6000 Emulator User’s Manual (HS2000EPI61HE).  2. Verify the user system interface cable connections by accessing the external memory and ports  to check the bus states of the pins with the MEMORY_FILL command (emulator command).  If an error is detected, recheck the soldered IC socket and the location of pin 1.  3. The emulator 
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        Section 5   Notice  1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  head before inserting the cable head into the user system IC socket.  2. The dimensions of the recommended mount pad for the user system IC socket are different from  those of the MCU.  3. This user system interface cable is specifically designed for the HS2338EPI61H emulator.  Do  not use this cable with any other emulator station.  4. To prevent breaking of wires in the cable 
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                          Figure 11 P1 Short Connector  16