Streszczenie treści zawartej na stronie nr. 1
H8/3257 Series DP-64S
User System Interface Cable
(HS3257ECS61H)
for E6000 Emulator
User’s Manual
Rev. 3.0
4/1/03
Renesas Technology Corp.
HS3257ECS61HE(C)
Streszczenie treści zawartej na stronie nr. 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Streszczenie treści zawartej na stronie nr. 3
Preface Thank you for purchasing the E6000 emulator for the Renesas’s original microcomputer H8/3257 series. The HS3257ECS61H is a user system interface cable that connects an H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a DP-64S package for the H8/3257 series MCU on the user system. i
Streszczenie treści zawartej na stronie nr. 4
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .........................................3 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ..........................
Streszczenie treści zawartej na stronie nr. 5
Section 1 Configuration CAUTION Use an IC83-64075-GS4 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the DP-64S package IC socket on the user system. Figure 1 shows the configuration of the HS3257ECS61H user system interface cable for the DP-64S package. Figure 1 HS3257ECS61H User System Interface Cable 1
Streszczenie treści zawartej na stronie nr. 6
Table 1 lists the HS3257ECS61H components. Please make sure you have all of these components when unpacking. Table 1 HS3257ECS61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 2 For protection of the DP-64S package 4 Documentation 1 User’s manual for HS3257ECS61H (this manual) 2
Streszczenie treści zawartej na stronie nr. 7
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before c
Streszczenie treści zawartej na stronie nr. 8
Emulator station Figure 2 Connecting User System Interface Cable to Emulator Station 4
Streszczenie treści zawartej na stronie nr. 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cab
Streszczenie treści zawartej na stronie nr. 10
Pin 1 Cable head IC socket (IC83-64075-GS4 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 3 Connecting User System Interface Cable to User System 6
Streszczenie treści zawartej na stronie nr. 11
2.2.3 Fastening Cable Body Connect the cable body to the cable head. Figure 4 Fastening Cable Body 7
Streszczenie treści zawartej na stronie nr. 12
2.3 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 4. Figure 5 Dimensions for User System Interface Cable Head 8
Streszczenie treści zawartej na stronie nr. 13
2.4 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 5. IC83-64075-GS4 IC83-64075-GS4 Figure 6 Resulting Dimensions after Connecting User System Interface Cable 9
Streszczenie treści zawartej na stronie nr. 14
Section 3 Verifying Operation 1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator according to the procedures described in the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator connected to this user system interfac
Streszczenie treści zawartej na stronie nr. 15
Section 4 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do not use this cable with any other emulator station. 3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable. 4. While the emulator statio