Streszczenie treści zawartej na stronie nr. 1
QuickSpecs
HP AlphaServer GS1280 Systems
Overview
HP AlphaServer GS1280 Models 8 and 16
1. Cable/DSL HUB
2. PCI/PCI-X I/O Expansion Drawer (optional)
3. PCI/PCI-X I/O Master Drawer (mandatory option)
4. System Building Block Drawer (Model 8 Includes 1 drawer, Model 16 includes 2 drawers)
5. 48-volt DC Power shelves, 3 power supplies per shelf (Model 8 includes 1 shelf, Model 16 includes 2 shelves)
6. AC input controller(s) (mandatory option)
DA - 11921 Worldwide — Version 24 — July 23, 20
Streszczenie treści zawartej na stronie nr. 2
QuickSpecs HP AlphaServer GS1280 Systems Overview HP AlphaServer GS1280 Model 32 1. Cable/DSL HUB 2. I/O Expansion Drawer (optional) 3. I/O Master Drawer (mandatory option) 4. System Building Block Drawer (Model 32 includes four drawers) 5. Power supply, dual AC input is standard 6. AC input controllers (two mandatory options for Model 32) DA - 11921 Worldwide — Version 24 — July 23, 2007 Page 2
Streszczenie treści zawartej na stronie nr. 3
QuickSpecs HP AlphaServer GS1280 Systems Overview HP AlphaServer GS1280 Model 64 1. Cable/DSL HUB 2. I/O Expansion Drawer (optional) 3. I/O Master Drawer (one drawer is optional) 4. System Building Block Drawer (Model 64 includes eight drawers) 5. Power supply, dual AC input is standard (two included for Model 64) 6. AC input controllers (two mandatory options for Model 64) DA - 11921 Worldwide — Version 24 — July 23, 2007 Page 3
Streszczenie treści zawartej na stronie nr. 4
QuickSpecs HP AlphaServer GS1280 Systems Overview At A Glance AlphaServer GS1280 Systems Up to 64 Alpha 21364 EV7 processors at 1300 MHz and 1150 MHz with advanced on-chip memory controllers and switch logic capable of providing 12.3 GB/s of memory bandwidth per processor Choice of memory options; up to 8 GB of RDRAM memory per CPU supported (512 GB total for a 64P system) Redundant features providing maximum uptime - N+1 Voltage Regulator Modules (VRMs); hot- plug redundant power supplies; cool
Streszczenie treści zawartej na stronie nr. 5
QuickSpecs HP AlphaServer GS1280 Systems Standard Features Processor Up to 64 Alpha 21364 EV7 processors at 1300 MHz and 1150 MHz Cache Memory 1.75-MB ECC L2 on-chip cache, 7-way set associative Architecture Glue-less processor-to-processor multiprocessor architecture constructed from a set of basic components: System Building Block Drawers CPU Building Block Modules I/O Expansion Building Block Drawers CPUs, Memory, and I/O slots GS1280 Model Maximum CPUs supported 64 (64 per hard partition for
Streszczenie treści zawartej na stronie nr. 6
QuickSpecs HP AlphaServer GS1280 Systems Standard Features Service and Support Protected by HP Services including a 1-year on-site hardware warranty. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support. DA - 11921 Worldwide — Version 24 — July 23, 2007 Page 6
Streszczenie treści zawartej na stronie nr. 7
QuickSpecs HP AlphaServer GS1280 Systems Systems Step 1 - Requirements Step 1a - System Requirements Mandatory Purchases: The system cannot function without these options or services - the option or service must be ordered with the system. Base System (Step 2) Dual CPU Building Block Modules (Step 3) Memory (Step 4) Master I/O Building Block Drawer (Step 5) Power Distribution Unit(s) (Step 6) Optional Purchases: I/O Building Block Drawer(s) (Step 5) System disk(s) (Step 5) Dual AC Power (Step 7)
Streszczenie treści zawartej na stronie nr. 8
QuickSpecs HP AlphaServer GS1280 Systems Systems 1. One Dual CPU Building Block Module (Step 3) 2. Memory (Step 4) 3. I/O Drawer (Step 5) a. One Standard I/O Drawer (Master or Expansion), or b. Shared (up to four hard partitions) access to one High Performance I/O Drawer (Master or Expansion) 4. One local disk (Step 5) or external storage for the system software. Network boot can be used in place of the disk storage. 5. User access via the USB port in a Master I/O Drawer, a network connection (r
Streszczenie treści zawartej na stronie nr. 9
QuickSpecs HP AlphaServer GS1280 Systems Systems Step 1d - System Management Hardware/Software Requirements Each AlphaServer ES47, ES80, and GS1280 system includes System Management software that can significantly enhance and simplify monitoring and control of the system. Use of the System Management software is optional. The software, which runs on a separate Intel or Alpha system, consists of two major components: 1. Alpha Management Station (AMS) - for monitoring and control of multiple ES47,
Streszczenie treści zawartej na stronie nr. 10
QuickSpecs HP AlphaServer GS1280 Systems Systems Step 3 - CPU Building Block Modules – Mandatory M=Mandatory O=Optional Supported Configurations CPUs 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 36 40 44 48 52 56 60 64 Dual CPU Modules 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 20 22 24 26 28 30 32 GS1280 Model 8 M O O O - - - - - - - - - - - - - - - - - - - - GS1280 Model 16 M O O O O O O O - - - - - - - - - - - - - - - - GS1280 Model 32 M O O O O O O O O O O O O O O O - - - - - - - - GS1280 M
Streszczenie treści zawartej na stronie nr. 11
QuickSpecs HP AlphaServer GS1280 Systems Systems iCAP CPU Building AlphaServer GS1280 iCAP Dual CPU Building Block Module, 1300 MHz, Tru64 3X-KN72D-CB Block Modules UNIX SMP License AlphaServer GS1280 iCAP Dual CPU Building Block Module, 1300 MHz, 3X-KN72D-CC OpenVMS SMP License AlphaServer GS1280 iCAP Dual CPU Building Block Module, 1150 MHz, Tru64 3X-KN72C-CB UNIX SMP License AlphaServer GS1280 iCAP Dual CPU Building Block Module, 1150 MHz, 3X-KN72C-CC OpenVMS SMP License iCAP Enablement
Streszczenie treści zawartej na stronie nr. 12
QuickSpecs HP AlphaServer GS1280 Systems GS Options Step 4 - Select Memory Options - Mandatory Configuration Guidelines 1. Mandatory selection of one memory option per CPU (two memory options per Dual CPU Building Block Module). 2. Optional selection of a second memory option for each CPU. 3. Both options must be the same size and speed for a CPU, but different size options can be used on different CPUs. 4. Each memory option consists of four RDRAM Inline Memory Modules (RIMMs). An optional fi
Streszczenie treści zawartej na stronie nr. 13
QuickSpecs HP AlphaServer GS1280 Systems GS Options Configuring memory is a compromise between cost, total memory capacity, and memory bandwidth requirements. The following may be used as guidelines: Applications, in which large amounts of memory can substantially reduce I/O throughput, may be optimized for total memory capacity and future capacity growth. (Case B) Typical commercial applications, such as transaction processing (OLTP) and multi-user timesharing, usually operate efficiently from
Streszczenie treści zawartej na stronie nr. 14
QuickSpecs HP AlphaServer GS1280 Systems GS Options Total I/O Drawer Connections =12 I/O connections used I/O Module I/O Buses I/O Slots Dual USB/ DVD/ Universal Part Number for Redundant Ultra3 CD-RW Slot for Connection Power SCSI Drive Disks to CPU in a Supplies Adapter System Card Building Block Drawer Standard I/O 1 3 PCI-X 8 PCI-X Yes No No None 3X-BA70A-BA Drawer, 1 AGP 4X 1 PCI 3.3V; Expansion 2 PCI, 5V 1 AGP 4X 4 Standard I/O 1 3 PCI-X 8 PCI-X Yes 1 in PCI 1 2 3X-BA70A-AA Drawer,
Streszczenie treści zawartej na stronie nr. 15
QuickSpecs HP AlphaServer GS1280 Systems GS Options NOTES: 1. One High Performance I/O Drawer can be used by up to four separate hard partitions. Each of the four I/O connections (and two associated PCI-X slots) in the High Performance I/O Drawer can be independently controlled (e.g. power on/off) in conjunction with a separate partition. 2. A Master I/O Drawer consists of a Standard or High Performance I/O Drawer plus a Combination Adapter in one slot. The Combination Adapter provides an Ultra3
Streszczenie treści zawartej na stronie nr. 16
QuickSpecs HP AlphaServer GS1280 Systems GS Options Step 7 - Dual AC Power - Optional A Dual AC power option provides the capability to connect to two separate AC feeds: a primary AC feed and a secondary AC feed. The feeds can be direct from the power utility, or they can be a combination of utility feeds and UPS or generator feeds. The preferred (primary) feed is determined by the user. In the event of failure of the primary feed, the system will automatically transfer the load to the seconda
Streszczenie treści zawartej na stronie nr. 17
QuickSpecs HP AlphaServer GS1280 Systems GS Options AlphaServer GS1280 Model 8 with Dual AC Option AlphaServer GS1280 Model 16 with Dual AC Option DA - 11921 Worldwide — Version 24 — July 23, 2007 Page 17
Streszczenie treści zawartej na stronie nr. 18
QuickSpecs HP AlphaServer GS1280 Systems GS Options Dual AC Power Options for GS1280 Model 32 and Model 64 Systems not originally equipped with Dual AC (DA/DY- 1280A-AC/AD) GS1280 Model 32 and Model 64 systems that were not originally equipped with power supplies that included dual AC capability (DA/DY-1280A-AC/AD) may be upgraded in the field to a power supply with Dual AC. Configuration Guidelines 1. The upgrade consists of one new power supply rack that replaces the existing power supply rack
Streszczenie treści zawartej na stronie nr. 19
QuickSpecs HP AlphaServer GS1280 Systems GS Options AlphaServer GS1280 Model 16 - Internal System Expansion Options DA - 11921 Worldwide — Version 24 — July 23, 2007 Page 19
Streszczenie treści zawartej na stronie nr. 20
QuickSpecs HP AlphaServer GS1280 Systems GS Options AlphaServer GS1280 Model 32 and Model 64 - Internal System Expansion Step 9 - External Rack Expansion - Optional Expansion Racks can be configured to hold I/O Drawers and StorageWorks components. External Expansion Rack, 41U, 2m 3X-H9A45-ZA Mandatory with External One required for Model 8 or North America/Japan 200 -208V, NEMA 3X-H7606-AA Expansion Rack, above Model 16 systems. Second L21-30P 30A; 3 x C19 outlets plus 24 x Type