Streszczenie treści zawartej na stronie nr. 1
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and seria
Streszczenie treści zawartej na stronie nr. 4
ELECTRICAL REQUIREMENTS The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front). Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord. Wiring Requirements Power Supply Cord • 115 volt (103.5 min.—126.5 Electrical Shock Hazard max) Plug into a grounded 3 prong outlet. • 0-12 amps Do not r
Streszczenie treści zawartej na stronie nr. 5
PACKING LIST 2/5” 3/4” Sash Lock (1) Screw (4) Screw (6) Packing List: • Sash Lock (1) • Window Air Conditioner • Window Sash Seal • Remote Control • 3/4” Screw for Sash Lock & Accordion • AAA Batteries (2) Panels (6) • Top Mounting Rail • Foam Top Window Gasket • Top Mounting Rail Seal Strip • Owner’s Manual • 2/5” Screw for Top Mounting Rail (4) • Accordion Panels (Left & Right) 4
Streszczenie treści zawartej na stronie nr. 6
SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the unit. Model SG-WAC-06SE SG-WAC-06ESE SG-WAC-08ESE Power Supply (Ph/V/Hz) 1/115/60Hz 1/115/60Hz 1/115/60Hz Dehumidifying Capacity (Pints/Day) 31.2 36 40.8 Rated Cooling Capacity (BTU/h) 6,000 6
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION & ASSEMBLY INSTRUCTIONS Some assembly is required for your new air conditioner. Please read and follow these instructions carefully. 1. This air conditioner is designed to be installed in a FIG. 1 standard double-hung window with a window width between 21” and 38” . 2. The air conditioner can be installed without the 21 38 accordion panels to fit in a narrow window opening. See the window dimensions. 13.5 3. The Lower Sash (the lower part of the window that moves
Streszczenie treści zawartej na stronie nr. 8
ASSEMBLY & INSTALLATION (CONT.) Accordion Panel Installation Storm Window Requirements A storm window frame will not allow the air conditioner to Now that you have installed the top rail, you can now install tilt properly which in turn will keep it from draining properly. the accordion panels on each side. To adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at 1. Place the air conditioner on a hard flat surface. least 1 1/2”.
Streszczenie treści zawartej na stronie nr. 9
ASSEMBLY & INSTALLATION (CONT.) 3. To secure the lower sash into place, use the sash lock Sash Lock and Foam Seal Installation and a 3/4” screw as shown below (See FIG. 12) MOUNTING HARDWARE FIG. 13 Qty 6 3/4” Screws Sash Lock 1 Tools Needed: 4. For added insulation, cut the supplied insulation foam to Phillips Screw Driver the width of the window. Insert the foam between the Drill (if plot holes are
Streszczenie treści zawartej na stronie nr. 10
USING YOUR AIR CONDITIONER 1. Power Button: Turns the air conditioner on and Electronic Control Panel & Remote Control off 2. Digital Display: Displays the current room tem- perature or the amount of time left on the timer. When the light is on the unit is in Shows the Set Temp when setting the tempera- This display always shows the room temperature or timer set mode. temperature except when setting ture. Shows the Timer Set when setting the timer. the Set temperature or the Time
Streszczenie treści zawartej na stronie nr. 11
USING YOUR AIR CONDITIONER (Cont.) • Freezing Conditions: This is a cooling only air • Fan Only Mode: Use Fan Only mode at Low, conditioner. It is not designed for freezing outdoor Med, or High fan speed to provide air circulation conditions. It must not be used in freezing outdoor and filtering without cooling. Since fan only setting conditions. do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in • Remote Control: To ensure
Streszczenie treści zawartej na stronie nr. 12
Cabinet Cleaning CARE AND CLEANING To clean the air conditioner cabinet: Clean your air conditioner to keep it looking new and to minimize dust build up. • Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front panel of Air Filter Cleaning the air conditioner may be dusted with an oil- The air filter should be checked at least once free cloth or washed with a cloth dampened in every month to see if it needs cleaning. Trapped a solution of warm water and
Streszczenie treści zawartej na stronie nr. 13
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged • Make sure the air conditioner is plug is pushed completely into the outlet • Check the house fuse/circuit The fuse is blown/circuit breaker is breaker box and replace the fuse tripped. or reset the breaker. • The unit will automatically re-start Power Failure when power is restored. • There is a protective time delay (app
Streszczenie treści zawartej na stronie nr. 14
TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS Water is dripping outside Hot and Humid weather. • This is normal Water is dripping inside the room The air conditioner is not correctly • For proper water drainage, make tilted outside. sure the air conditioner is slightly tilted downward from the front of the unit to the rear. Water collects in the base pan Moisture removed from the air is • This is normal for a short period in draining into the base pan. are
Streszczenie treści zawartej na stronie nr. 15
WARRANTY One Year Limited Warranty Soleus International, Inc. warrants the accompanying Soleus Air Powered by Gree Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International will, at its option, either repair or replace it, free of charge within a reasonable tim
Streszczenie treści zawartej na stronie nr. 16
66129903754