OPERATING AND INSTALLATION MANUAL
Model: KFIHP-09-ID / KFHIP-09-OD
KFHHP-12-ID / KFHHP-12-OD
Indoor Unit.
Outdoor Unit.
Thank you for selecting Soleus Air. To ensure proper
operation, please read this manual and keep it for
future reference.
Streszczenie treści zawartej na stronie nr. 2
TABLE OF CONTENTS STRUCTURE AND OPERATION...……………………..……………………………………….....1-8 Name of Each Part …………………………………………………………….………..………...……1 The Instructions before Use…………………………………………………………………………2-3 Specifications and Technical Data……………………………….……..……………….…………….4 Remote Control Operation………………………………………………….….…...............………5-6 How to Insert Batteries……………………………………………..………………….………...……7 Operation………………………………………………………………………………………...……8 INSTALLATION...……………………..………………………………………………
Streszczenie treści zawartej na stronie nr. 3
Structure and Operation ◆Name of Each Part - 1 -
Streszczenie treści zawartej na stronie nr. 4
◆The Instructions before Use Warning ★Grounding: The unit must be properly ★Disconnect the power when the unit is not being grounded. used for extended periods of time. ★Don’t attempt to repair the air conditioner by ★If your air conditioner malfunctions, yourself. There are no user replaceable parts. discontinue use and call your authorized dealer. Please contact your authorized dealer. ★Never block the air inlet or outlet of indoor
Streszczenie treści zawartej na stronie nr. 5
◆The Instructions before Use ★Set the room temperature appropriately. ★Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the The difference between indoor direction of air flow. and outdoor temperature shall be 40 °F. ★Close all doors & windows for efficient ★To avoid harm to your pets or plants, never operation. direct the air
Streszczenie treści zawartej na stronie nr. 6
◆Specification and Technical Data KFIHP-09-ID KFHHP-12-ID Model KFIHP-09-OD KFHHP-12-OD Function Cool / Heat Accessory Air Cleaner Cooling capacity (Btu/h) 9000 12000 Heating capacity (Btu/h) 9500 13000 Power Supply (V) 115V~ 208~230 Frequency (Hz) 60 Cooling/Heating rated current(A) 12/13.6 9/10 Cooling/Heating rated power(W) 1250/1450 1700/1750 Cooling/Heating power input(W) 730/840 1100/1200 3 Recycling air Volume(m /h) 550 Refrigerant and weight(lbs) R410
Streszczenie treści zawartej na stronie nr. 7
◆Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will automatically resume its last running mode, and the outdoor unit will start there after. MODE Button: TEMP+ TEMP- Button: When the unit is turned on, press this Under the COOL, DRY, button. The AUTO, FAN or HEAT mode, COOL, DRY, FA
Streszczenie treści zawartej na stronie nr. 8
◆Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. SWING Button: ON/OFF Button Press once to have louvers Press ON. swing [oscillate]. Press Press OFF. twice in one second the panel light will turn on. Press twice again and the light will turn off. T-ON Button. When pressing this button once, enter into T-ON setting, the icon of T-ON flash, every press of T-OFF Button TIME+, the time of T-ON will
Streszczenie treści zawartej na stronie nr. 9
◆How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (Two AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • Don’t mix different batteries. • Remove batteries when not in use for a longtime. • The batteries can be used for about one year. • Keep remote at least 3.28 feet from TV’s and other electronic devices. When the wireless remote control is lost or broken, please use
Streszczenie treści zawartej na stronie nr. 10
◆Operation The general procedure: 1. Power the unit and a buzzer will sound. Power/Run indication is red and the air conditioner is waiting to run. (Note: Once the air conditioner plugs to power supply or receives the signal of remote control, the buzzer will send out the desirable sound.) 2. Press ON/OFF button, Power/Run indication is green and shows the running mode (Cooling, Heating, and Auto), and then the air conditioner starts running. 3. Press MODE butto
Streszczenie treści zawartej na stronie nr. 11
Installation ◆Installation Location Indoor Unit 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location from which the condensation water can be drained out conveniently and that is permitting easy connection with the outdoor unit. 3. Avoid a location where there is heat source, steam or inflammable gas. 4. Install in a location where it can withstand the full weight and vibration of the u
Streszczenie treści zawartej na stronie nr. 12
◆Electric Wiring 1. All the electric work must be done according to the wiring diagram. 2. Check for the correct voltage of the unit. 3. Don’t pull the power cord strongly. 4. The air conditioner must be safely grounded! Grounding wire must be connected to the building and done by the qualified personnel. In fixed circuit, there must be electricity leakage protection switch of enough power capacity and air switch with enough space. Air switch (thermal-magnetic bre
Streszczenie treści zawartej na stronie nr. 13
◆Installation Dimension Diagram Important Notes The installation must be done by trained and qualified service personnel. 112.6 inch 212.6 inch - 11 -
Streszczenie treści zawartej na stronie nr. 14
◆Installation • Install the rear panel 1. Always mount the rear panel horizontally. Because the mouth of drainage pipe is at the left side and the left side of the rear panel is better to adjust slightly lower. 2. Fix the rear panel on the selected location with 50 50 screws supplied with the unit. 3. Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult of 132.3 lbs; furthermore, the weight should be evenly share
Streszczenie treści zawartej na stronie nr. 15
◆Installation 4. Connect the Neutral wire of the power connection cables to the “N (1)” terminal of the terminal board, connect the Signal wire to the “2” terminal, and connect the live wire to the“3”terminal and connect the grounding wire to the “ ” terminal. 5. Reassemble the wiring cover and tighten the screw. 6. Recover the surface panel. - 13 -
Streszczenie treści zawartej na stronie nr. 16
◆ Install the Indoor Unit 1. When routing the piping and wiring from the left or right side of the indoor unit, cut off the tailings from the chassis in necessary (shown in Fig.4 (a), (b) and (c)). (1) Cut off the tailings 1 when routing the wiring only. (2) Cut off the tailings 1 and tailings 2 (or tailings 1, tailings 2 and tailings 3) when routing both the wiring and piping. ①, ②, and ③ in Fig. 4 are the recommended piping. 2. Wrap the piping and wiring and pull them through
Streszczenie treści zawartej na stronie nr. 17
◆Install the Outdoor Unit • Install the connection pipe 1. Align the center of the piping flare with the valve. 2. Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to right figure. Tightening Torque Table Hex Nut Diameter Tightening Torque (mm) (N.m) Φ6 15~20 φ12 50~55 Note: Exceeding tightening torque will damage the flare nut. • Electric wiring connection 1. Disassemble the big h
Streszczenie treści zawartej na stronie nr. 18
◆Install the Outdoor Unit • Air Purging and Leakage Test 1. Remove the flare nuts of charging end from gas valve. 2. Connect the charging hose in the middle to the vacuum pump, then Low-pressure (Lo) end should be connected to charging end of gas valve. (Shown in Fig. 9) 3. Open the vacuum pump to evacuate. When multi-meter indicates 1 bar, fully tighten Lo handle of manifold valve and stop evacuation. Keep it for over 15 minutes to ensure the pressure is const
Streszczenie treści zawartej na stronie nr. 19
◆Test Operation and Check after Installation Test Operation 1. Before Test Operation (1) Do not switch on power before installation is finished completely. (2) Electric wiring must be connected correctly and securely (3) Cut-off valves of the connection pipes should be opened. (4) All the impurities such as scraps must be cleared from the unit. 2. Test Operation Method (1) Switch on power and press “ON/OFF” button on the remote control to run the air con
Streszczenie treści zawartej na stronie nr. 20
Care and Maintenance ◆Care and Maintenance CAUTION: Turn power off and pull out the power cord before cleaning air conditioner. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile Liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.) Clean the front panel (Don’t remove the fro