CONTACT INFORMATION Website: wolfappliance.com As you follow these instruc tions, you will notice WARNING and CAUTION symbols. This blocked information is impor tant for the safe and efficient installation of Wolf equip- ment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Anothe
Streszczenie treści zawartej na stronie nr. 5
WOLF WARMING DRAWER INSTALLATION REQUIREMENTS IMPORTANT NOTE: This installation must be Record the model and serial numbers before completed by a qualified technician. installing the warming drawer. Both numbers are listed on the product rating plate, located Installer: Please read the entire Installation on the left front floor area of the inner cabinet. Model ICBWWD30 Instructions prior to installation. Save these with Stainless Steel To access the rating plate, the drawer must be instructions
Streszczenie treści zawartej na stronie nr. 6
WOLF WARMING DRAWER BEFORE YOU START DRAWER FRONT OPTIONS Before you install the warming drawer, IMPORTANT NOTE: Model ICBWWD30 must make sure you have the Wolf accessory be installed with a Wolf stainless steel or drawer front called for in your installation. integrated drawer front. IMPORTANT NOTE: If you are installing Classic Stainless Steel WWDFRONT/S the warming drawer with integrated drawer ACCESSORIES Integrated Drawer Front WWDFRONT/I front in an inset panel application, make (accepts w
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION INSTRUCTIONS STAINLESS STEEL DRAWER FRONT INSTALLATION SPECIFIC ATIONS MODEL ICBWWD30 with Stainless Steel Drawer Front The following illustrations provide the overall dimensions and installation specifications for Overall Width 759 mm the Wolf warming drawer with a stainless steel Overall Height 260 mm drawer front. Overall Depth 689 mm Wolf recommends using a 838 mm wide Depth Behind Frame* 597 mm cabinet for the warming drawer with stainless steel drawer front. A minimum 762 mm w
Streszczenie treści zawartej na stronie nr. 8
WOLF WARMING DRAWER STAINLESS STEEL DRAWER FRONT INSTALLATION WITH BUILT-IN OVEN IMPORTANT NOTE: Additional clearance between warming drawer and oven openings The Wolf warming drawer with stainless steel may be required. Check that oven supports do drawer front may be installed below or above not obstruct the interior dimensions required a Wolf 762 mm built-in single oven or below a for the warming drawer. double oven, provided the warming drawer is When the warming drawer is installed below ful
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION INSTRUCTIONS STAINLESS STEEL DRAWER FRONT OPTIONAL INSTALLATIONS The Wolf warming drawer with stainless steel drawer front may be installed in combination with a 762 mm single oven and microwave oven with 762 mm trim, provided the warming drawer is fully enclosed, top and bottom. Refer to the illustration below. Also refer to installa- tion instructions provided with the built-in oven and microwave for additional specifica- tions. Dimensions will vary according to the specific insta
Streszczenie treści zawartej na stronie nr. 10
WOLF WARMING DRAWER INTEGRATED DRAWER FRONT INSTALLATION SPECIFIC ATIONS MODEL ICBWWD30 with Integrated Drawer Front The following illustrations provide the overall dimensions and installation specifications for Overall Width 746 mm the Wolf warming drawer with integrated Overall Height 257 mm drawer front. The warming drawer with inte- Overall Depth* (behind frame) 597 mm grated drawer front can be used in an overlay application or an inset panel application where Minimum Cabinet Requirements i
Streszczenie treści zawartej na stronie nr. 11
INSTALLATION INSTRUCTIONS INTEGRATED DRAWER FRONT OVERLAY APPLIC ATION UNDERCOUNTER INSTALLATION A minimum 838 mm wide by 610 mm deep For undercounter installations, 597mm from cabinet is required for the warming drawer the bottom of the warming drawer opening to with integrated drawer front using the overlay the floor is recommended. It must be installed application. A minimum base support of 91 kg a minimum of 127 mm above the floor or is required. Refer to the illustration on page 10. 25 mm
Streszczenie treści zawartej na stronie nr. 12
WOLF WARMING DRAWER INTEGRATED DRAWER FRONT INSTALLATION WITH BUILT-IN OVEN IMPORTANT NOTE: Additional clearance between warming drawer and oven openings The Wolf warming drawer with integrated may be required. Check that oven supports do drawer front may be installed below or above not obstruct the interior dimensions required a Wolf 762 mm or 914 mm built-in single oven, for the warming drawer. provided the warming drawer is fully enclosed, When the warming drawer is installed below top and bo
Streszczenie treści zawartej na stronie nr. 13
INSTALLATION INSTRUCTIONS INTEGRATED DRAWER FRONT INSTALLATION OPTIONS Refer to installation instructions provided with the built-in oven and microwave for additional The Wolf warming drawer with integrated specifications. Dimensions will vary according drawer front may be installed in combination to the specific installation. with a 762 mm single built-in oven and The Wolf warming drawer with integrated microwave with 762 mm trim, provided the drawer front may be installed next to or above warm
Streszczenie treści zawartej na stronie nr. 14
WOLF WARMING DRAWER ELECTRICAL REQUIREMENTS The Wolf warming drawer requires a separate, In addition, be aware of local codes and ordi- grounded 220–240 V AC, 50/60 Hz power nances when installing your service. supply and must be connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or The electrical outlet must be checked by IMPORTANT time delay fuse. a qualified electrician to be sure that it is NOTE wired with the correct polarity. Verify
Streszczenie treści zawartej na stronie nr. 15
INSTALLATION INSTRUCTIONS CABINET SUPPORTS UNPACK THE WARMING DRAWER IMPORTANT NOTE: When the warming Unpack the warming drawer on a flat surface. drawer is installed with a built-in oven, Remove all packaging materials and tape from additional clearance between openings may be inside the warming drawer and discard. Do not required. Check that oven supports do not discard the package containing the two wood obstruct the interior dimensions required for screws needed for installation. the warmin
Streszczenie treści zawartej na stronie nr. 16
WOLF WARMING DRAWER STAINLESS STEEL FRONT PANEL INSTALL ANTI-TIP BLOCKING INSTALL WARMING DRAWER TRIM Remove all packaging materials from the trim. The stainless steel drawer front kit comes with An anti-tip block or platform must be two long trim pieces for the top and bottom installed to prevent the warming drawer collar of the warming drawer and two short from tipping forward while opened when trim pieces for the sides. Each trim piece has a loaded. Failure to do so could result in groove tha
Streszczenie treści zawartej na stronie nr. 17
INSTALLATION INSTRUCTIONS STAINLESS STEEL FRONT PANEL INSTALL FRONT PANEL INSTALL WARMING DRAWER Slide the left corner of the warming drawer Remove all packaging materials from the into the opening. If the electrical outlet is handle and front panel. Gently remove the installed inside the opening, plug the power protective covering from the stainless steel cord into the outlet. The excess cord should be front panel. The adhesive covering should peel coiled behind or beside the unit. If the outle
Streszczenie treści zawartej na stronie nr. 18
WOLF WARMING DRAWER INTEGRATED FRONT PANEL INSTALL CLEATS AND PLATFORM IMPORTANT NOTE: Be sure to finish the inside lip of the opening and the front face of For an overlay or inset application, you will the shelf and cleats. Some of these areas will need to install a recessed platform and cleats be visible when the drawer is open. of the following dimensions into the opening. IMPORTANT NOTE: Be aware of the location Top Cleat Dimensions of the mounting holes on the warming drawer 749 mm W x 13 m
Streszczenie treści zawartej na stronie nr. 19
INSTALLATION INSTRUCTIONS INTEGRATED FRONT PANEL INSTALL ANTI-TIP BLOCKING INSTALL WARMING DRAWER Install a 51 mm x 51 mm or 51 mm x 102 mm Turn power off to the electrical outlet. Slide the anti-tip block against the rear cabinet wall as left corner of the warming drawer into the shown in the installation illustration for your opening. If the electrical outlet is installed specific installation on pages 11–13. inside the opening, plug the power cord into the outlet. The excess cord should be co
Streszczenie treści zawartej na stronie nr. 20
WOLF WARMING DRAWER INTEGRATED FRONT PANEL INSTALL FRONT PANEL TO DRAWER Route out the rectangular areas (8 locations) Disconnect the communications line from marked on the back of the decorative panel communications jack. The communications 6.35 mm deep. jack is removed by depressing retaining clip from front of mounting panel, then pushing Attach the handle hardware to the front of the the retaining clip side of jack through decorative panel. The integrated drawer front mounting panel first,