Streszczenie treści zawartej na stronie nr. 1
®
BUNN
OT & RT
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
32440.0000B 7/00 © 1999 BUNN-O-MATIC CORPORATION
!
!
CAUTION
DISCARD DECANTER
IF:
. CRACKED
. B . S OC ILR EA DT D CR HY E D
. HEATED WHEN EMPTY
. USED ON HIGH FLAME
FUNNEL CONTENTS E . L O E R M E EX NP TO SSED ELECTRIC
ARE HOT
FAILURE TO COMPLY RISKS INJURY
PN: 658 1985 BUNN-O-MATIC CORPORATION
CAUTION
DISCARD D
Streszczenie treści zawartej na stronie nr. 2
CONTENTS Introduction ............................................................... 2 User Notices .............................................................. 3 Electrical Requirements ............................................. 4 Plumbing Requirements ............................................ 4 Initial Set-Up.............................................................. 5 Adjusting Brew Volumes............................................ 6 Operating Controls...........................
Streszczenie treści zawartej na stronie nr. 3
USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protection. All notices on the equipment should be kept in good condition. Replace any unreadable or damaged labels. 00658.0000 00831.0000 ! WARNING Fill water tank before turning -on thermostat or connecting appliance to power source. Use only on a properly protected circuit capable of the rated load. Electrically ground the chassis. Follow national/local electrical codes. Do not
Streszczenie treści zawartej na stronie nr. 4
HI ELECTRICAL REQUIREMENTS CAUTION - Do not connect the brewer to the power source until specified in Initial Set-Up. L2 RED WHITE WHITE L2 RED NEUTRAL 120V.A.C. 120V.A.C. WHITE NEUTRAL L1 BLACK 200 OR 240V.A.C. 120V.A.C. 208 or 240V.A.C. L1 BLACK L1 BLACK NEUTRAL 120V.A.C. L1 BLACK MODELS OT15 & 20 require 2- MODELS OTA, RTA & RT35B MODELS OT35 & RT35 require MODEL RT requires 2- wire, grounded service rated require 2-wire, grounded ser- 3-wire, grounded service rated wire, grounded service 120
Streszczenie treści zawartej na stronie nr. 5
PLUMBING REQUIREMENTS (Cont.) Plumbing Hook-Up Model OT15 has an attached water strainer, proceed to step 2. Models OT20, OT35, & RT35, proceed as follows: 1. Remove the rear panel and bottom pan. Run the long piece of tubing from the strainer (supplied) under the brewer and attach it to the water inlet fitting on the solenoid. Reinstall the bottom pan and rear panel. 2. Flush the water line and securely attach it to the 1/4" flare fitting on the strainer. 3. Turn on the water supply. INITIAL
Streszczenie treści zawartej na stronie nr. 6
ADJUSTING BREW VOLUMES CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement or adjustment of any component. NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place. 1. Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board. To increase a batch size. Press
Streszczenie treści zawartej na stronie nr. 7
Streszczenie treści zawartej na stronie nr. 8
TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. • All electric components have 120 volt ac voltage on their terminals. Shorting of terminals or the application of external vol
Streszczenie treści zawartej na stronie nr. 9
TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Brew cycle will not start. (cont.) 4. On/Off Brew Station Warmer Refer to Service - On/Off Brew Sta- Switch tion Warmer Switch for testing pro- cedures. See page 18. Refer to Service - Start Switch for 5. Start Switch testing procedures. See page 23. Refer to Service - Timer for testing 6. Brew Timer procedures. See page 13 & 14. 7. Solenoid Valve Refer to Service - Solenoid Valve for testing procedures. See page 22. Refer to Service - Sol
Streszczenie treści zawartej na stronie nr. 10
TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Spitting or unusual steaming from 1. Control Thermostat Refer to Service - Control Thermo- sprayhead. stat for testing procedures. See page 16. 2. Lime build-up Inspect the tank assembly for exces- sive lime deposits. Delime as re- CAUTION quired. Tank and tank components should be delimed regularly depending on local water conditions. Excessive mineral build-up on stainless steel surfaces can initiate corrosive reac- tions resulting in se
Streszczenie treści zawartej na stronie nr. 11
TROUBLESHOOTING (cont.) Problem Probable Cause Remedy 1. Beverage left in decanter The brew cycle should be started Beverage overflows decanter. only with an empty decanter under the funnel. 1. Type of paper filters BUNN® paper filters should be used Weak beverage. for proper extraction. 2. Coffee A sufficient quantity of fine or drip grind coffee should be used for proper extraction. 3. Sprayhead B.O.M. sprayhead #01082.0000 should be used to properly wet the bed of ground coffee in the funnel.
Streszczenie treści zawartej na stronie nr. 12
Streszczenie treści zawartej na stronie nr. 13
If voltage is present as described, reconnect the po- SERVICE (cont.) larized, three-pin connectors, and proceed to #6. If voltage is not present as described, refer to the Wir- Brew Timer (Early Models) ing Diagrams and check the brewer wiring harness. 6. Disconnect the in-line connectors on the black and white wires from the timer to the solenoid. 7. Check the voltage across the black and white wires with a voltmeter when the On/Off brew sta- tion warmer switch is in the upper position and the
Streszczenie treści zawartej na stronie nr. 14
SET LOCK J1 J2 SERVICE (cont.) 6. Disconnect the white/blue wire from terminal TL3 and the blue/black wire from terminal TL5. With a DIGITAL BREW TIMER (Late Models) voltmeter, check for continuity across the two wires when the "ON/OFF" switch is in the "ON" position (upper) and the START switch is pressed. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models. b) 200 or 240 volts ac for two wire 200 or 240 volt models and three wire 12
Streszczenie treści zawartej na stronie nr. 15
SERVICE (cont.) 2. Setting brew volumes. To set a brew volume, first check that the SET/LOCK switch is in the “SET” DIGITAL BREW TIMER (Late Models)(cont.) position on the circuit board. Place the ON/OFF switch 3. Remove all wires from the timer. in the “ON” position, press and hold the START switch 4. Attach all wires to the replacement timer board until three distinct clicks are heard and then release prior to installation to the component mounting the switch. (Failure to release the switch w
Streszczenie treści zawartej na stronie nr. 16
Streszczenie treści zawartej na stronie nr. 17
Streszczenie treści zawartej na stronie nr. 18
Streszczenie treści zawartej na stronie nr. 19
SERVICE (cont.) 3. Check the voltage across terminal 1 and the white or red wire on the terminal block with a voltme- Warmer Switch(es) ter when the switch is in the "ON" position. Con- RT: Left Rear, Left Front, Right Rear & Right Front nect the brewer to the power source. The indica- tion must be as described in step 1. Voltage must not be present across these terminals in the "OFF" positions. 4. Disconnect the brewer from the power source. If voltage is present as described, the switch is
Streszczenie treści zawartej na stronie nr. 20