Streszczenie treści zawartej na stronie nr. 1
FMD-1
FMD-2
S/N FMD0013000-UP
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
29112.0000C 01/06 ©1998 Bunn-O-Matic Corporation
PUSH and HOLD BUTTON UNTIL CUP
PUSH and HOLD BUTTON UNTIL CUP
IS 2/3 FULL, THEN RELEASE
IS 2/3 FULL, THEN RELEASE
RELEASE BUTTON WHEN CUP IS 2/3 FULL RELEASE BUTTON WHEN CUP IS 2/3 FULL
PLACE PLACE
PLACE
CUP HERE CUP HERE
CUP HERE
Streszczenie treści zawartej na stronie nr. 2
INTRODUCTION This equipment dispenses hot beverages or soups on demand from powered product. It is for indoor use only on a sturdy counter or shelf. WARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. In addition: 1.) Bunn warrants electronic circuit and/or control boards to be commercially free from defects
Streszczenie treści zawartej na stronie nr. 3
USER NOTICES (Cont.) This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /SanitationCode. 00656.0000 00831.0000 27096.0000 FMD-1 ONLY 28368.0001 PUSH and HOLD BUTTON UNTIL CUP PUSH and HOLD BUTTON UNTIL CUP IS 2/3 FULL, THEN RELEASE IS 2
Streszczenie treści zawartej na stronie nr. 4
INITIAL SET-UP 1. Locate the drip tray assembly beneath the dispenser nested in the packing material. 2. Remove the drip tray and the drip tray cover and set them aside. 3. Remove the water strainer assembly from the drip tray and set it aside. 4. Remove the four legs from the packaging material, apply non-skid pads to the bottom of the legs and securely install the legs in the dispenser base. ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be disconnected from the power source until speci
Streszczenie treści zawartej na stronie nr. 5
INITIAL FILL & HEAT CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Turn-on the water supply and connect the dispenser to the power source. 2. Water will automatically flow into the tank to the proper level and then shut-off. This will take less than five minutes. 3. When the tank is full of water, open the front door and place the heater switch in the “ON” (lower) position. A tank full of cold water
Streszczenie treści zawartej na stronie nr. 6
COLD BEVERAGE SET-UP (OPTIONAL FMD-2 ONLY) Cold beverages may be dispensed from the left dispense position as follows: 1. Disconnect the dispenser from the power source. 2. Remove the lower front access panel. 3. Locate the Hot/Cold jumper connection near the whipper panel in the main wiring harness. 4. Remove the Hot jumper connection (red jumper plug) from the main wiring harness and connect the Cold jumper connection (blue jumper plug) to the main harness. 5. Replace the lower front access pa
Streszczenie treści zawartej na stronie nr. 7
HOPPER MOTOR SPEED PROGRAMING (FMD-2) The hopper dispense rate is preset at the factory. With 22 tooth gear and auger wire the preset dispense rate is approximately 3 to 5 grams per second. With 32 tooth gear and auger wire the preset dispense rate is approximately 5 to 7 grams per second. The hopper dispense rate can be adjusted to a range of dispense rates from approximately 1.5 to 12 grams per second, as follows: 1. Place the rinse/run switch in the center (program) position. 2. Place the inc
Streszczenie treści zawartej na stronie nr. 8
TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. • All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the appl
Streszczenie treści zawartej na stronie nr. 9
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY 5. Solenoid Valve (Inlet) Refer to Service - Solenoid Valve Product will not dispense (cont.) (Inlet) for testing procedures. See page 36 6. A) Level Control Board and Probe Refer to Service - Level Control Board - FMD-1 and Probe for testing procedures. See page 30 B) Control Board and Probe - FMD- Refer to Service - Control Board and 2 Probe for testing procedures. See page 20 7. A) Auger Drive - FMD-1 Refer to Service - Auger Drive. S
Streszczenie treści zawartej na stronie nr. 10
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Water is not hot (Cont.) 4. Tank Heater Switch Refer to Service - Tank Heater Switch for testing procedures. See page 38 Spitting or excessive steaming 1. Lime build-up Inspect the tank assembly for exces- CAUTION - Tank and tank compo- sive lime deposits. Delime as re- nents should be delimed regularly quired. depending on local water conditions. Excessive mineral build-up on stain- less steel surfaces can initiate corro- sive reactions res
Streszczenie treści zawartej na stronie nr. 11
TROUBLESHOOTING (cont.) PROBLEM REMEDY PROBABLE CAUSE Product overflows container 1. Dispense Switch Refer to Service - Dispense Switch for testing procedures. See page 22 Remove the solenoid valve and clear 2. Dispense Solenoid Valve any obstructions. Rebuild or replace the valve if necessary. See page 35 Weak product 1. Water Temperature Place an empty container beneath the dispense tip. Initiate a dispense cycle and check the water tempera- ture immediately below the dispense tip with a the
Streszczenie treści zawartej na stronie nr. 12
TROUBLESHOOTING (CONT.) PROBLEM PROBABLE CAUSE REMEDY Dispenser is making unusual 1. Plumbing Lines Plumbing lines should not be rest- ing on the counter top. noises 2. Water Supply (A) The dispenser must be connected to a cold water line (B) Water pressure to the dispenser must not exceed 90 psi (620 kPa). Install a regulator if necessary to lower the working pressure to ap- proximately 50 psi (345 kPa). Remove and clean lime off the tank 3. Tank Heater heater. See page 37 1. Fan Refer to Servi
Streszczenie treści zawartej na stronie nr. 13
AUGER DRIVE COMPONENTS FMD-1 SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Re- fer to Troubleshooting for assistance in determin- ing the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by quali- fied service personnel. The dispenser should be unplugged when servicing, except when electrical tests are required and the test proc
Streszczenie treści zawartej na stronie nr. 14
SERVICE AUGER DRIVE COMPONENTS - FMD-1 (CONT.) 1 5. Check the voltage across the positive (red wire) terminal and the negative (black wire) terminal on 2 the auger motor with a voltmeter. With the rinse/ run switch in the run (lower) position press and hold the dispense switch. Connect the dispenser to the power supply. After a .6 second delay the 3 indication must be 4.0 to 24.5 volts dc. 4 5 7 If voltage is present as described, the auger motor 13 drive is operating properly. If auger does no
Streszczenie treści zawartej na stronie nr. 15
12 11 9 8 7 AUGER DRIVE COMPONENTS - FMD-2 SERVICE (cont.) AUGER DRIVE COMPONENTS - FMD-1 (cont.) Auger Drive Motor (Refer to Fig. 2) 1. Remove hopper assy (17), and set aside for reas- sembly. 2. Remove the four #8-32 screws securing the hop- per support plate (12), remove plate and set aside for reassembly. 3. Remove the four #8-32 screws, located inside the dispenser housing on the lower right front of the auger motor mounting panel (21), securing auger motor mounting bracket (18) and auger
Streszczenie treści zawartej na stronie nr. 16
SERVICE (cont.) AUGER DRIVE COMPONENTS - FMD-2 (CONT.) 1 4 2 4. Disconnect the dispenser from the power supply. 11 If voltage is present as described and the auger does 6 not turn, replace the auger motor. 3 If voltage is not present as described, refer to the wir- 5 ing diagrams and check the dispenser wiring harness. 7 Removal, Cleaning and Replacement Hopper & Auger (Early Models)(Refer to Fig. 5) 12 8 1. Open the dispenser door and raise the top front 13 9 cover. 10 2. Lift the front edg
Streszczenie treści zawartej na stronie nr. 17
SERVICE (cont.) AUGER DRIVE COMPONENTS - FMD-2 (cont.) 1 2 Removal, Cleaning and Replacement 4 Hopper & Auger (Late Models)(Refer to Fig. 6) 1. Open the dispenser door and raise the top front 5 3 cover. 8 2. Lift the front edge of hopper assy (20) over the tab on hopper support plate (19) and slide hop- per assembly out the front of the dispenser. 3. Remove hopper lid (1) and empty product. 7 9 4. Pull off the ejector elbow (13). 10 5. Remove agitator disc assy (2) by pulling agitator 6 support
Streszczenie treści zawartej na stronie nr. 18
12 11 9 8 7 SERVICE (cont.) LEFT AUGER DRIVE COMPONENTS - FMD-2 (cont.) RIGHT Auger Drive Motor (Refer to Fig. 5 or 6) 1. Remove all hopper assemblies (20) and set aside for reassembly. 2. Remove the four #8-32 screws securing the hop- per support plate (19), remove plate and set aside for reassembly. 3. Remove the four #8-32 locking screws, located inside the dispenser housing on the front of the RED to WHI/ORN from auger motor mounting panel (14), securing auger Control Board J3-2 motor mount
Streszczenie treści zawartej na stronie nr. 19
tighten the two #8-32 screws securing the compo- SERVICE (cont.) nent bracket to the dispenser housing base. BALLAST - FMD-1 & FMD-2 (cont.) Location FMD-1 BLK to BLK The front door lamp ballast is located behind from Main the front access panel on the left front side of the com- Wiring Harness ponent bracket. BLK to BLU from FMD-2 Main Harness The front door lamp ballast is located behind the front access panel on the left rear side of the com- ponent bracket. P1447 FIG. 9 BALLAST TERMINALS CON
Streszczenie treści zawartej na stronie nr. 20
12 11 9 8 7 CONTROL BOARD - FMD-2 ONLY SERVICE (cont.) CONTROL THERMOSTAT - FMD-1 & FMD-2 (cont.) a) 120 volts ac for two wire 120 volt models. b) 208 volts ac for three wire 120/208 volt models. c) 240 volts ac for three wire 120/240 volt models. 5. Disconnect the dispenser from the power source. If voltage is present as described the control thermo- stat is operating properly. Reinstall bulb into the tank. If voltage is not present as described, replace the thermostat. Removal and Replacement