Model 9311 Satellite Brewer
w/optional
3902 Drip Tray
PRINTED IN UNITED STATES OF AMERICA
p/n 74415 Rev. F ECN-12888 M661 05006
Streszczenie treści zawartej na stronie nr. 2
661 74415 9311 Single Satellite Brewer WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD It also does not apply if the serial nameplate has been INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service. workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment are based upo
Streszczenie treści zawartej na stronie nr. 3
TABLE OF CONTENTS Thank You for purchasing this WARRANTY STATEMENT xi Bloomfield Industries appliance. SPECIFICATIONS 1 Proper installation, professional FEATURES & OPERATING CONTROLS 2 operation and consistent PRECAUTIONS & GENERAL INFORMATION 4 maintenance of this appliance will AGENCY APPROVAL INFORMATION
Streszczenie treści zawartej na stronie nr. 4
661 74415 9311 Single Satellite Brewer FEATURES AND OPERATING CONTROLS Fig 1. SS-1 Satellite Brewing System Features & Operating Controls 2
Streszczenie treści zawartej na stronie nr. 5
FEATURES AND OPERATING CONTROLS (continued) Brewer Adjustable Legs Allows brewer to be leveled. Also allow clearance for cleaning underneath brewer. Bypass Nozzle Dilution water flows into satellite server from here. Connector Connects to satellite. Allows satellite heater to be energized. Allows brewer to sense that a satellite is in place. Hot Water Faucet Hot water dispensed here. Nameplate Lists manufacturer, model and serial num
Streszczenie treści zawartej na stronie nr. 6
661 74415 9311 Single Satellite Brewer GENERAL INFORMATION AND PRECAUTIONS This appliance is intended for use in commercial establishments WARNING: only. Electric This appliance is intended to brew hot beverage, specifically coffee, Shock hazard for human consumption. No other use is recommended or authorized All servicing requiring by the manufacturer or its agents. access to non-insulated Operators of this appliance must be familiar with the appliance use, electrical co
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION INSTRUCTIONS INSTALL LEGS CAUTION: Hazard from The brewer is provided with adjustable legs and rubber feet. Be Unstable Equipment sure the legs are securely screwed into the base of the brewer, and that the rubber feet are properly installed. Rubber feet must be installed LEVEL THE UNIT on each leg of the brewer. Legs must be adjusted so that The adjustable legs allow the brewer to be leveled. Set the brewer all four feet rest firmly on the in its ultimat
Streszczenie treści zawartej na stronie nr. 8
661 74415 9311 Single Satellite Brewer INSTALLATION INSTRUCTIONS (continued) ELECTRICIAN’S INSTALLATION INSTRUCTIONS CAUTION: Electric Shock Refer to Electrical Specifications, page 1. Hazard Brewer requires a dedicated single-phase circuit: Brewer must be properly Model 9311 120/240 Volt AC, 50/60 Hz 4-Wire 20 Amps. grounded to a reliable earth ground to prevent possible shock hazard. Do not assume a plumbing line will provide such a ground. Electric
Streszczenie treści zawartej na stronie nr. 9
OPERATING INSTRUCTIONS Fig. 4 Control Panel BREWING COFFEE Prepare the Brew Basket: Make sure the wire rack is properly installed in the brew chamber. Insert one (1) Bloomfield paper filter into the brew chamber. Make sure the filter is properly supported by the wire rack. Add a measured amount of grounds to the brew basket. Recommendations (may vary, depending on type of coffee and personal taste preferences): To brew 1/2
Streszczenie treści zawartej na stronie nr. 10
661 74415 9311 Single Satellite Brewer OPERATING INSTRUCTIONS (continued) Fig. 6 Water Flow Diagram BREW & BYPASS The time the BREW SOLENOID is open is The SS-1 is a modified displacement brewer. controlled by the TIMER For 1/2 and 1 gallon brews, there is no bypass. Water admitted into in response to the the hot water tank by the BREW SOLENOID will displace a like amount position of the VOLUME of heated water through the brew head, brew chamber and into the
Streszczenie treści zawartej na stronie nr. 11
CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer CAUTION: Burn Hazard PRECAUTIONS: Press POWER key to OFF. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Hot coffee will cause Bristle Brush serious skin burns. 1. Press POWER key to OFF. Al
Streszczenie treści zawartej na stronie nr. 12
661 74415 9311 Single Satellite Brewer CLEANING INSTRUCTIONS (continued) CAUTION: PROCEDURE: Clean Satellite Burn Hazard PRECAUTIONS: Drain Satellite before Cleaning Brewing and serving FREQUENCY: Twice Weekly temperatures of coffee are extremely hot. TOOLS: Sight Glass Brush, Sanitizer Hot coffee will cause Soft Clean Cloth, Bucket serious skin burns. 1. Remove and drain satellites. WARNING: 2. P
Streszczenie treści zawartej na stronie nr. 13
SERVICING INSTRUCTIONS CAUTION: TEMPERATURE ADJUSTMENT SHOCK HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Live electrical circuits are exposed during this procedure. FREQUENCY: As required to adjust delivered volume Use care to avoid uninsulated electrical connectors. TOOLS: Phillips head screwdriver Adjustments to be performed by 1. Press H
Streszczenie treści zawartej na stronie nr. 14
661 74415 9311 Single Satellite Brewer SERVICING INSTRUCTIONS (continued) CAUTION: BREW TIMER ADJUSTMENT SHOCK HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Disconnect brewer from electric power before opening the FREQUENCY: As required to adjust delivered volume access panel. TOOLS: Phillips head screwdriver Adjustments to be performed by Small fla
Streszczenie treści zawartej na stronie nr. 15
SERVICING INSTRUCTIONS (continued) QUALITY TIMER ADJUSTMENT CAUTION: SHOCK HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Disconnect brewer from electric power before opening the FREQUENCY: As required to adjust delivered volume access panel. TOOLS: Phillips head screwdriver The QUALITY TIMER flashes Satellite or other container to calibrate volume t
Streszczenie treści zawartej na stronie nr. 16
661 74415 9311 Single Satellite Brewer SERVICING INSTRUCTIONS (continued) CAUTION - PROCEDURE: Delime the Water Tank CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals are caustic. Wear appropriate protective FREQUENCY: As required (Brewer slow to heat) gloves and goggles during this procedure. TOOLS: Deliming Solution Never siphon deliming
Streszczenie treści zawartej na stronie nr. 17
SERVICING INSTRUCTIONS (continued) 10. Reinstall tank lid assembly into hot water tank. Make sure NOTE: Normally, silicone the lid gasket is properly in place, then reinstall the hold- hoses do not need to be down clamps. delimed. Should deliming hoses become necessary, 11. Remove spray disks and gaskets. Rinse both brew heads Bloomfield recommends with clean water. Using a stiff brush, scrub spray disk to remove any l
Streszczenie treści zawartej na stronie nr. 18
661 74415 9311 Single Satellite Brewer TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Will not heat or brew Brewer not plugged in or circuit Reconnect brewer to electric power (no lights) breaker tripped Reset circuit breaker Fuse blown Check satellite for water saturation Replace fuse Will not brew Satellite is not in proper position Reinstall satellite. Satellite light should be on Brew switch damaged Check. Replace if needed Timer damaged Check. R
Streszczenie treści zawartej na stronie nr. 19
TROUBLESHOOTING SUGGESTIONS (continued) SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Insufficient brew volume Timer out of adjustment Adjust time for each brew volume (any one volume only) Timer damaged Check. Replace if needed Volume select switch damaged Check. Replace if needed Insufficient brew volume Timer out of adjustment Adjust time for each brew volume (1-1/2 gallon brew only) Bypass solenoid damaged Check. Replace if needed Volume select switch damaged Check. Replace if n
Streszczenie treści zawartej na stronie nr. 20
661 74415 9311 Single Satellite Brewer MODEL 9311 EXPLODED VIEW 18