Streszczenie treści zawartej na stronie nr. 1
™
SUMMER RAIN
2 WALL & 3 WALL
WALK-IN SHOWER SYSTEMS
INSTALLATION AND OPERATING INSTRUCTIONS
Streszczenie treści zawartej na stronie nr. 2
IMPORTANT SAFETY INFORMATION Do not place or use electrically connected devices, such as television, radio, or stereo speakers, lights, hair dryers, or telephones, within 1.5 m (5 feet) of shower. Note: This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath produ
Streszczenie treści zawartej na stronie nr. 3
CONTENTS 2 WALL Specifications _________________________________________________________________________ 2 Rough-in Reference ____________________________________________________________________ 3 Component Identification ________________________________________________________________ 4 Base Installation _______________________________________________________________________ 5-7 Tower and Glass Panels Installation ________________________________________________________ 8-12 3 WALL Specificatio
Streszczenie treści zawartej na stronie nr. 4
2 WALL SPECIFICATIONS Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware. Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Immediately upon receipt, inspect the base and other components before installing. Check all carton inserts for parts and hardware. Should inspection reveal any damage or defect in any compon
Streszczenie treści zawartej na stronie nr. 5
2 WALL ROUGH-IN REFERENCE 84" FRONT VIEW 60" 33-3/4" 1-1/2" TILE FLANGE 23" 21-1/2" 1/2" RIGID 27-15/16" COPPER PIPE UNDER BASE 42-5/16" COLD SUPPLY HOT SUPPLY MINIMUM WATER PRESSURE FOR THE SYSTEM IS 40PSI TOP VIEW 3
Streszczenie treści zawartej na stronie nr. 6
2 WALL COMPONENT IDENTIFICATION TOWER WITH PLUMBING, FIXTURES, MAGNETIC HEX WRENCH (1) GASKET, BOTTOM PLATE CURVED STRAIGHT (PROVIDED) AND TOP COVER GLASS GLASS (PREASSEMBLED) MOUNTING WALL WALL POST MOUNTING MOUNTING WALL CAP (2) TOWER POST POST MOUNT SUPPORT BRACKET (2) RAIL GLASS PANEL SUPPORT FRONT BRACKET RAIL RAIL COVER (2) GLAZING GASKET TAPE (6 PIECES) 3 SCREWS AND 3 WALL ANCHORS PER MOUNTING POST GLAZING GASKET (3) CURVED STRAIGHT GLASS GLASS PANEL GLAZING GASKET TOWER COVER BOTTOM TOWE
Streszczenie treści zawartej na stronie nr. 7
2 WALL BASE INSTALLATION INSTALLATION INSTRUCTIONS PRELIMINARY ROUGH-IN The floor structure beneath the unit must be able to STEP 2 support a total weight of the unit and bather. Refer Remove the stainless steel strainer from the drain assembly. Disassemble the locknut and two gaskets to the table under total weight. from the back of the drain assembly. Apply a 1/4" bead of caulking (silicone) to the drain hole and insert the drain STEP 1 assembly. Replace the rubber washer, fiber washer, Pr
Streszczenie treści zawartej na stronie nr. 8
2 WALL BASE INSTALLATION STEP 4 STEP 5 With the drain fitting passing over the center of the With a large screwdriver and the tool included with the drainpipe, lower the shower base carefully into place, drain, tighten the inside compression nut to seal the push down firmly until the base is in place. You must drain pipe connection. After drain is fully installed, test check the level of the base in two directions. Do not lift for proper drainage. If the shower base does not drain a corner t
Streszczenie treści zawartej na stronie nr. 9
2 WALL BASE INSTALLATION STEP 6 STEP 8 Place cement board or equivalent on top of shower Filling the area marked DO NOT FILL will prevent base flange and secure to studwall. moisture from draining back into the base through the weep holes. This moisture is due to leakage through the tile grout. Sealing the tile grout will prevent this leakage. CEMENT BOARD TILE CEMENT BOARD GROUT STUD STUD SILICONE SEALANT SHIM IF NECESSARY DO NOT FILL STEP 7 Apply tile (or other finishing material) leaving a
Streszczenie treści zawartej na stronie nr. 10
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 1 STEP 3A Position the wall posts so the edge of the post is set back Slide straight glass panel all the way into wall post. Mark 3/4" (19 mm) in from the edge of the base position of glass post. Remove panel. 3/4" (19 mm) FINISH WALL EDGE OF BASE STEP 2 Level both wall posts in their proper position and mark where screw holes are to be drilled. Drill 3/16" holes and MARK POSITION secure with wall anchors and screws provided. Cut a
Streszczenie treści zawartej na stronie nr. 11
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 4 STEP 6 Slide the glass panel into the wall post. Make sure that Insert tower support rail into glass panel rail but do not the corner notch is positioned toward the base of the tighten at this time. tower. GLASS PANEL SUPPORT RAIL TOWER SUPPORT RAIL STEP 7 Insert support rails into brackets in top moulding of tower but do not tighten at this time. Front and tower support rails may have to be cut if they are too long. TOWER SUPPORT
Streszczenie treści zawartej na stronie nr. 12
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 9 STEP 11 Place the front rail and tower support rail against the Secure the rails. walls. Check level and mark the position for the rail mounting bracket. The screw position will be above the rail. Drill the wall with a 3/16" bit and secure bracket with screws and wall anchors provided. ATTACH RAIL BRACKET TO WALL SECURE RAIL TO BRACKET (TURN CW TO TIGHTEN) STEP 12 MOVE COVER CAP Tighten the tower base bolt. Two shut-off valves
Streszczenie treści zawartej na stronie nr. 13
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 14 STEP 13A Install cover cap on fixed glass wall post. Insert fixed glass support rail into panel post and tighten set screw. COVER CAP STEP 13B Drill a 1/8" pilot hole into tower support rail using the hole STEP 15 in the glass panel support rail. Screw M3.5X9.5 mm Install glazing gasket on curved glass wall post on the screw into hole. outside. Note orientation of gasket. Soapy water may help to insert the glazing gasket. On the
Streszczenie treści zawartej na stronie nr. 14
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 16 STEP 18 Turn on water supply and check for leaks. Correct any Seal all around the base of tower with silicone sealant. leaks before installing tower cover. Also seal the inside of both wall posts, glass post and the bottom of both glass panels on the inside only. STEP 17 Install tower cover as shown. Insert cover at top first. APPLY SEALANT ALONG BASE AND SIDE OF WALL POST TOWER TOP PLATE APPLY SEALANT ALONG BASE APPLY SEALANT OF
Streszczenie treści zawartej na stronie nr. 15
3 WALL SPECIFICATIONS Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware. Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Immediately upon receipt, inspect the base and other components before installing. Check all carton inserts for parts and hardware. Should inspection reveal any damage or defect in any compon
Streszczenie treści zawartej na stronie nr. 16
3 WALL ROUGH-IN REFERENCE 84" FRONT VIEW 60" 33-3/4" 1-1/2" TILE FLANGE 23" 21-1/2" 1/2" RIGID 27-15/16" COPPER PIPE UNDER BASE 42-5/16" COLD SUPPLY HOT SUPPLY MINIMUM WATER PRESSURE FOR THE SYSTEM IS 40PSI TOP VIEW 14
Streszczenie treści zawartej na stronie nr. 17
3 WALL COMPONENT IDENTIFICATION TOWER WITH PLUMBING, FIXTURES, MAGNETIC HEX WRENCH (1) GASKET, BOTTOM PLATE CURVED (PROVIDED) AND TOP COVER GLASS (PREASSEMBLED) WALL MOUNTING MOUNTING POST POST CAP WALL TOWER MOUNT SUPPORT BRACKET (2) RAIL FRONT BRACKET RAIL COVER (2) TAPE (3 PLACES) 3 SCREWS AND 3 WALL ANCHORS GLAZING GASKET CURVED GLASS GLAZING GASKET (2) TOWER COVER TOWER MOUNTING BOLT & WASHER SELF DRILLING SCREW BASE 15
Streszczenie treści zawartej na stronie nr. 18
3 WALL BASE INSTALLATION PRELIMINARY ROUGH-IN INSTALLATION INSTRUCTIONS The floor structure beneath the unit must be able to STEP 2 support a total weight of the unit and bather. Refer Remove the stainless steel strainer from the drain assembly. Disassemble the locknut and two gaskets to the table under total weight. from the back of the drain assembly. Apply a 1/4" bead STEP 1 of caulking (silicone) to the drain hole and insert the drain Provide an opening in the subfloor no less than 5" x 5
Streszczenie treści zawartej na stronie nr. 19
3 WALL BASE INSTALLATION STEP 4 STEP 5 With the drain fitting passing over the center of the With a large screwdriver and the tool included with the drainpipe, lower the shower base carefully into place, drain, tighten the inside compression nut to seal the push down firmly until the base is in place. You must drain pipe connection. After drain is fully installed, test check the level of the base in two directions. Do not lift for proper drainage. If the shower base does not drain a corner t
Streszczenie treści zawartej na stronie nr. 20
3 WALL BASE INSTALLATION STEP 6 STEP 7 With the drain fitting passing over the center of the With a large screwdriver and the tool included with the drainpipe, lower the shower base carefully into place, drain, tighten the inside compression nut to seal the push down firmly until the base is in place. You must drain pipe connection. After drain is fully installed, test check the level of the base in two directions. Do not lift for proper drainage. If the shower base does not drain a corner t