Streszczenie treści zawartej na stronie nr. 1
SEDONA™
Steam & Shower Base
INSTALLATION/OPERATING INSTRUCTIONS
Streszczenie treści zawartej na stronie nr. 2
IMPORTANT SAFETY INFORMATION READ ALL INSTALLATION INSTRUCTIONS Jacuzzi Whirlpool Bath does not recommend prolonged periods of use of the steamer. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia). Consult your physician about your safety and comfort before using the steam system. Limit your use of steam to 10–15 minutes until you are certain of your body’s reaction. A cool
Streszczenie treści zawartej na stronie nr. 3
CONTENTS Specifications _________________________________________________________________________ 2 Roughing-in Reference _________________________________________________________________ 2 Framing and Support ___________________________________________________________________ 3 Steam Enclosure _____________________________________________________________________ 4 SteamPro™ Drain Down Configurations ___________________________________________________ 4 Digital Control & Temperature Sensor Rou
Streszczenie treści zawartej na stronie nr. 4
Important: Read complete instructions before beginning installation. Each shower base is shipped with a drain and stainless steel strainer Remove the shower base from the carton. Do not destroy the shipping carton until after satisfactory inspection of the product. Immediately upon receipt, inspect the base before installing. Should inspection reveal any damage or defect in the finish, do not install the base. Damage or defect to the finish claimed after the base is installed is excluded fro
Streszczenie treści zawartej na stronie nr. 5
FRONT OF DOUBLE STUDS Framing and Support The drain extends below the bottom of the base. Note that this requires a cutout in the floor. The floor structure beneath the base must be able to support a total weight of base, and bather. The unit must be supported from the bottom of the base and not from the tile flange. If the subfloor is level, no other preparation is necessary. You can proceed to install the base. If the subfloor is not level, you MUST level the entire surface prior to insta
Streszczenie treści zawartej na stronie nr. 6
2" DOME HEIGHT NOTE: ADDITIONAL 2" REQUIRED TO INSTALL OR REMOVE DOME DOME TOP OF ENCLOSURE HEADER 85-3/8" 77-1/2" 12-3/4" TOP OF THRESHOLD 5-7/8" UNIT WITH JACUZZI WHIRLPOOL BATH OPTIONAL STEAM ENCLOSURE Drain Down Locations There are several locations (left hand unit shown) where the optional automatic valve may be located when connecting to a drain line as shown in illustration. Right hand unit is mirror image. Exact location to be determined by installer. The manual drain valve can be mov
Streszczenie treści zawartej na stronie nr. 7
Control and Temperature Sensor Cable Rough-in A rough-in wiring kit is provided with unit to allow installer to locate and run wires to the temperature sensor and digital controller before finish walls are installed. Control Cable Rough-in The low voltage control can be mounted up to 25 feet from the generator either inside or outside the steam room. String the 25' cable from the generator through 1/2" holes in the wall studs or ceiling joists to the controller location. Note: Do not staple thro
Streszczenie treści zawartej na stronie nr. 8
Base Drain Water Supply Remove the stainless steel strainer from the drain Consult local authorities for plumbing code require- assembly. Disassemble the locknut and two gaskets ments in your area. Connect house cold water supply to from the back of the drain assembly. Apply a 1/4" bead steam generator supply tubing. of caulking (silicone) to the drain hole and insert the drain IMPORTANT: Jacuzzi Whirlpool Bath does not assembly. Replace the rubber washer, fiber washer, warrant connections
Streszczenie treści zawartej na stronie nr. 9
Controller Mounting Finished Wall Mounting The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. Using a 2" hole saw, drill a hole in the finished wall where the control is to be mounted (the control cable should already be roughed-in to this location). Locate the control cable, pull it out through the 2" hole and plug it into the connector on the back of the control housing. With the decorative cover removed, screw the two 3" control housin
Streszczenie treści zawartej na stronie nr. 10
Temperature Sensor Mounting Finish Materials The temperature sensor should be mounted 6" below Apply tile (or other finishing material) leaving a 1/8" gap the ceiling or dome, inside the steam room, but not between the finishing material and the base flange lip. directly over the steam dispersion head or more than 7 Seal this gap with silicone sealant. Leave a minimum feet above the floor. Using a 7/8" hole saw, drill a hole 1/4" weep hole at the back and front corners of the base . in the fin
Streszczenie treści zawartej na stronie nr. 11
Note: The combined thickness of the tile (or other Service Access finish material), adhesive and cement board must not Service access is through the removable panel. To exceed the edge of the vertical wall on the drain side. remove panel, grab the middle of the panel and bow This condition will not allow the wall jamb of the steam outwards till clips disengage. enclosure to sit flat against the vertical wall. SERVICE ACCESS PANEL FINISH SURFACE DRAIN TILE FLUSH WITH VERTICAL WALL GRAB PANEL IN
Streszczenie treści zawartej na stronie nr. 12
Operation The digital control features an adjustable 60 minute time and temperature control with digital display. The actual room temperature and time remaining are alternately displayed every 5 seconds. The temperature can be adjusted in a range between 100 degrees and 125 degrees Fahrenheit with an initial default of 120 degrees. Once the set temperature is reached the ‘’soft steam’’ feature automatically engages cutting steam production back to a single element. If the steam room temperatu
Streszczenie treści zawartej na stronie nr. 13
Troubleshooting There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call the Service Department at 1-800- 363-0251 (This number is only for service for the steam generator.). The Trouble Shooting Guide below is meant as a general aid only. Follow ACTION TO BE TAKEN in order until the problem is resolved. 11
Streszczenie treści zawartej na stronie nr. 14
Troubleshooting 12
Streszczenie treści zawartej na stronie nr. 15
Wiring Diagram 13
Streszczenie treści zawartej na stronie nr. 16
PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT. Jacuzzi Whirlpool Shower base has obtained applicable code (standards) listings generally available on a national basis for products of this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation of the product. Jacuzzi Whirlpool Shower base makes no representation or warranty regarding, and will not be responsibl
Streszczenie treści zawartej na stronie nr. 17
Jacuzzi Whirlpool Bath Limited Warranty Steam Generator Products Jacuzzi Whirlpool Bath, warrants that its Steam Generators (warranted products) are free of manufacturing defects both as to workmanship and material for 5 years and it will replace or repair defective parts or equipment for the period of time and in accordance with the conditions set forth below. The terms of the warranty will be administered by Saunatec Inc. dba, AMEREC. 1. Applicability. This warranty applies when the warrante
Streszczenie treści zawartej na stronie nr. 18
6. Procedure. Requests for repair or replacement, a return authorization number, or warranty information should be directed to AMEREC by calling toll-free 1-800-363-0251 or by writing to AMEREC, 17683 128th Place N.E., Woodinville, WA 98072. Defective product or parts returned for repair or replacement must be shipped prepaid to AMEREC at the above address. Shipping costs for return of replacement product or parts to the purchaser will be at the expense of the purchaser. 7. Limitations, Exclu
Streszczenie treści zawartej na stronie nr. 19
Jacuzzi Whirlpool Bath Limited Warranty Builder Group Bath Product WARRANTY COVERAGE Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Builder Group Bath Product (“unit”) who purchases the product for personal or single family use (“user”). The Company will repair or replace, at its option, the unit or its equipment in accordance with the following terms and conditions. ONE YEAR LIMITED WARRANTY ON BATHS O
Streszczenie treści zawartej na stronie nr. 20
Warranty Registration Card This card must be filled out and returned to the address printed on the other side within thirty (30) days from date of purchase in order for this warranty to be come effective. Purchaser's Name ________________________________________ Purchaser's Address _______________________________________ City _____________________________ State _____ Zip ________ Date of Purchase _________________________________________ Model Name _____________________________________________ S