Streszczenie treści zawartej na stronie nr. 1
The.Danger.signal.indicates.an.immediately.hazardous.situation.which,.
if.not.avoided,.will result.in.death.or.serious.injury.
The.Warning.signal.alerts.you.to.potential.hazards.or.unsafe.practices.which,.
if.not.avoided,.could result.in.severe.personal.injury.or.death.
The.Caution.signal.alerts.you.to.hazards.of.unsafe.practices.which,.if.not.avoided,.
may.result.in.minor.personal.injury.or.property.damage.
Please.be.certain.that.the.person.who.installs.or.uses.this.appliance.carefully.
reads.a
Streszczenie treści zawartej na stronie nr. 2
Table of Contents Warranty...........................................................................................................4 Introduction/Typical Installation . Introduction.......................................................................................4 . Typical.Installation.............................................................................4 Waste Xpress Features...................................................................................5 WX-101A Control Featu
Streszczenie treści zawartej na stronie nr. 3
Warranty WASTE XPRESS SYSTEM LIMITED WARRANTY ® ® The.InSinkErator .Waste.Xpress,.disposer.and.control.centers.are.warranted.against.defects.in.material.and. workmanship.for.one.year.from.the.date.of.installation..The.warranty.includes.parts.and.labor,.provided.an.. InSinkErator.Factory.Authorized.Service.Center.performs.the.service..This.warranty.does.not.apply.if.the.failure.. is.due.to:.faulty.or.improper.electrical.installation,.faulty.or.improper.plumbing.installation,.product.abuse.or.. mi
Streszczenie treści zawartej na stronie nr. 4
Waste Xpress Features CONSTRUCTION FEATURES Stainless.steel.construction.(for.physical.size.see.. COMPACT.SIZE ® Figure.3). The.Waste.Xpress .is.designed.to.fit.under.a.34".high commercial.kitchen.table. WASTE.MIX The.Waste.Xpress.can.process.non-food.waste.such WASTE.REDUCTION as.paper,.light.and.rigid.plastic.or.food.wrappings.when Reduces.volume.by.85%. mixed.with.a.minimum.of.50%.food.waste. SAFETY.INTERLOCK The.Waste.Xpress.is.equipped.with.safety.interlock.. on.the.discharge.chute.(see.Fig
Streszczenie treści zawartej na stronie nr. 5
WX-101A Control Features/Mounting Control Center ® The.WX-101A.Control.Center.is.UL .approved.for.use. with.InSinkErator.Waste.Xpress.food.waste.reduction. systems..The.control.center.operates.the.disposer.and. ELECTRICAL SHOCK Waste.Xpress..Its.main.functions.are: .•.Ensure.that.Waste.Xpress.voltage.and.phase. match.that.of.the.electrical.supply,.control.center.. •.To.start.and.stop.the.disposer/Waste.Xpress.system. &.disposer..Check.nameplate.for.specification. •.To.reverse.the.direction.of.th
Streszczenie treści zawartej na stronie nr. 6
Installing Disposer CLEAN.THE.DRAIN.LINE With.a.drain.line.auger,.clear.away.all.hardened.waste material.in.the.horizontal.drainpipe.running.from.the PERSONAL INJURY drain.trap.to.the.main.waste.line. .•.For.safe.operation,.The.minimum.required.distance . from.the.table.top.or.trough.to.the.mounting.flange. is.6.inches.for.standard.body.disposers.. (as.specified.by.UL)..See.Figure.5. 6" min. (152.4 mm min.) .•.Moving.shredder.parts.may.cause.serious.injury.if. a.hopper.or.cone.is.not.properly.in
Streszczenie treści zawartej na stronie nr. 7
InSinkErator Mounting Assemblies 4..From.the.bottom,.insert.two.screws.through.opposite STANDARD MOUNTING ASSEMBLY . sides.of.the.flat.gasket.(3).and.mounting.flange,.into 1..Place.mounting.flange.(1).over.the.existing.collar . the.threaded.fasteners.in.the.existing.flange..The . adaptor.connection.lip.or.sink.bowl.flange.(this.may . flat.gasket.is.used.only.in.the.#6.mounting.assembly. . require.some.force). . The.screws.should.protrude.about.1/4".below.the 2..Push.the.mounting.flange.up.out.of
Streszczenie treści zawartej na stronie nr. 8
Installing the Waste Xpress 45˚ bend shown (max of 4 can be used) 1-1/2" 3" (38.1 mm) (76.2 mm) Figure 11. Top View Syphon Breaker Sink Bowl Cold Water Solenoid Hot Water Solenoid Waste Xpress 1-1/2" min 1" min (38.1 mm (25.4 mm min) min) Disposer Flow Control Valve Shut Off Valve (supplied by others) WX-101A Controller 10 max (3.1 m max) Figure 12. Typical Installation Diagram 9
Streszczenie treści zawartej na stronie nr. 9
Installing the Waste Xpress 7....Connect.wire.bundle.between.WX-101A.and.. WASTE XPRESS LOCATION Waste.Xpress.unit.as.detailed.in.wiring.diagram.. NOTE: Prior to installing the Waste Xpress the Door.interlock.connections.are.#3.and.#95..Replace. disposer and control center should be installed as terminal.cover. specified within this manual. 8....Wire.per.local.electrical.codes.and.install.. •.Position.Waste.Xpress.within.10.feet.of.the.disposer using.NEMA.4.watertight.electrical.connectors.. out
Streszczenie treści zawartej na stronie nr. 10
Plumbing Connections PROPERTY DAMAGE Water.connections.must.comply.with.all.local. plumbing.codes. WASTE INLET LINE Connect.the.disposer.outlet.flange.as.close.as.. possible.and.with.as.few.as.possible.90°.elbows.to.. the.Waste.Xpress.inlet. NOTE: The maximum allowable distance between the Figure 15. disposer outlet flange and the Waste Xpress inlet is 10 feet with a maximum of four (4) 90° elbows. 1..Connect.the.disposer.outlet.to.the.Waste.Xpress.. . inlet.using.2".NPT.plumbing..3.HP.will.re
Streszczenie treści zawartej na stronie nr. 11
Plumbing Connections WASTE OUTLET LINE WATER SUPPLY CONNECTIONS Connect.a.2".drain.line.to.the.Waste.Xpress.waste.. When.connecting.the.incoming.water.supply.to.the outlet.as.specified.per.local.codes.(see.Figure.18.. disposer,.sink.bowl.and.Waste.Xpress,.use.as.few for.water.outlet.location). elbows.and.tees.as.possible. InSinkErator.recommends.that.the.water.outlet.. All.cold.water.line.fittings.are.1/2".NPT.except.the empties.into.a.floor.drain. sink.bowl.nozzles.which.are.1/2".compression...
Streszczenie treści zawartej na stronie nr. 12
Electrical Connections ELECTRICAL SHOCK PROPERTY DAMAGE .•.Turn.off.all.electrical.supply.to.the.disposer.before. .•.Ensure.that.control.center.voltage.and.phase attempting.any.work.on.it..Use.a.voltmeter.or.. . match.the.disposer.motor.and.electrical.supply... circuit.tester.to.ensure.that.power.is.off. . Check.nameplates.on.disposer.and.control.. . center.for.voltage.and.phase.specifications. .•.All.Installation.work.must.conform.to.local.. plumbing.and.electrical.codes. .•.Refer.to.the.contro
Streszczenie treści zawartej na stronie nr. 13
Operating Instructions PRE-OPERATION TEST Before.operating.the.Waste.Xpress.complete.. the.following.steps.to.ensure.the.unit.has.been.. PERSONAL INJURY properly.installed. If.system.does.not.shut.down.when.front.. cover/discharge.chute.is.removed,.interlock.may. 1....Ensure.plumbing.and.electrical.connections.. not.be.wired.correctly..See.Troubleshooting.section. are.secure. for.corrective.action. 2....Turn.on.incoming.cold.water.supply.to.disposer.. and.hot.water.supply.to.the.Waste.Xpress. 3.
Streszczenie treści zawartej na stronie nr. 14
Operating Instructions TO.START 1..Check.to.ensure.disposer.is.free.of.foreign.objects. 2..Ensure.power.is.on. 3..Push.start.button..Disposer.and.Waste.Xpress.will. run.and.water.will.flow.into.disposer TO.STOP 1..Push.stop.button..System.will.stop. 2..Water.may.continue.to.flow.into.disposer.for.up.to.. 10.minutes,.per.the.time.set.on.the.water.shutoff. delay.timer..This.post-flush.clears.the.drain.lines.. of.food.waste. WATER.SHUTOFF.DELAY.ADJUSTMENT This.water.shutoff.delay.is.adjustable.from
Streszczenie treści zawartej na stronie nr. 15
Operating Instructions OPERATING WASTE XPRESS SYSTEM 1..Make.sure.there.are.no.foreign.objects.in.disposer. grind.chamber..Do.not.pre-load.disposer.with.food. waste.prior.to.starting. 2..Place.10.gallon.waste.bin.under.discharge.chute. 3..Push.start.button.on.control.center..Waste.Xpress. and.disposer.will.run.and.water.will.flow.into.disposer. 4..Feed.food.waste.into.disposer.in.a.steady,.. continuous.flow..Waste.will.exit.discharge.chute.. and.drop.into.waste.bin. NOTE: Once all waste has been
Streszczenie treści zawartej na stronie nr. 16
Cleaning Instructions PERSONAL INJURY Discharge Chute Wait.until.auger.paddles.stop.before.cleaning. Waste.Xpress. 1....Press.stop.button.on.control.center.to.stop.system. (disposer.&.Waste.Xpress). 2....Holding.both.handles.remove.discharge.chute.by.. tilting.it.upward.(see.Figure.25). 3....Remove.auger-bearing.bracket.by.sliding.the.two. captive.fasteners.inward.and.then.pull.bracket.. Figure 25. upward.(see.Figure.26.and.27). 4....Lift.auger.and.screen.up.and.then.out.. (see.Figure.26). 5....
Streszczenie treści zawartej na stronie nr. 17
Troubleshooting ELECTRICAL SHOCK PERSONAL INJURY •.Disconnect.power.before.servicing. Wait.until.auger.paddles.stop.before.servicing. Waste.Xpress. •.Do.not.bypass.interlock.switch. Troubleshooting.for.problems.other.than.what.is.listed.below.should.be.performed.by.a.qualified.service.person.. Troubleshooting.performed.by.untrained.personnel.could.result.in.electrical.shock.or.damage.to.the.Waste.Xpress,. disposer.and/or.Control.Center. SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The.
Streszczenie treści zawartej na stronie nr. 18
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Water.backs.up.into.disposer.. •. The.auger.and.screen.plugged. •. Remove.plug. (does.not.drain). •. Auger.not.turning.. •. Ensure.that.auger.is.seated.properly.and.. . that.auger.belt.in.place..Check.motor. •. Plumbing.line.between.disposer.and.. •. Remove.clog. . Waste.Xpress.clogged. Waste.Xpress,.disposer.and.water. •. Insufficient.time.allowed.after.Line.. •. Allow.15-20.seconds.prior.to.attempting.. will.start.when."sta
Streszczenie treści zawartej na stronie nr. 19
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION No.water.spraying.onto.. •. Solenoid.valve.clogged. •. Remove.clog. auger.screen. •. Water.turned.off. •. Turn.on.water. •. Solenoid.valve.defective. •. Call.for.service. •. Spray.nozzles.clogged. •. Replace.nozzles. •. Timer.defective. •. Call.for.service. •. Timer.not.set.properly. •. Call.for.service. •. Solenoid.valve.installed.incorrectly. •. Reinstall.solenoid.valve.so.arrow.is.pointing. . in.correct.direction. Water.fl
Streszczenie treści zawartej na stronie nr. 20
Troubleshooting DISPOSER TROUBLESHOOTING PROBLEM CAUSE SOLUTION Disposer.motor.will.not.start.and. •. No.incoming.line.power. •. Turn.line.power.on. water.does.not.flow. •. Line.disconnect.switch.is.not.on.. •. Turn.line.disconnect.to."on".position..Wait.. . . 15-20.seconds.before.attempting.to.start.. . system.to.allow.control.to.perform."self.test." •. Line.disconnect.switch.has.been.. •. Wait.30.seconds.and.try.starting.again.. . reactivated.and.30-second.delay.. . . has.not.yet.expired. •. L