The Danger signal indicates an immediately hazardous situation which, if not
avoided, will result in death or serious injury.
The Warning signal alerts you to potential hazards or unsafe practices which,
if not avoided, could result in severe personal injury or death.
The Caution signal alerts you to hazards of unsafe practices which, if not avoided,
may result in minor personal injury or property damage.
Please be certain
Streszczenie treści zawartej na stronie nr. 2
Table of Contents Introduction/Features Introduction ..................................................................................... 3 Features .......................................................................................... 3 Mounting The Control Center/Plumbing Connections Mounting the Control Center........................................................... 4 Plumbing Connections .................................................................... 4 Electrical Connection D
Streszczenie treści zawartej na stronie nr. 3
Introduction/Features NOTE: When the disposer is first turned on, both INTRODUCTION ® ® solenoids will operate. After the set time has expired, the The AS-101K Control Center is UL and CUL approved flow to the disposer will slow to one gallon per minute if for use with InSinkErator Foodservice Disposers. See there is not food waste present in the grinding chamber. Table 1 for approved disposer and control center combinations. The control center operates the disposer AUTOMATIC TIMED DISPO
Streszczenie treści zawartej na stronie nr. 4
Mounting the Control Center/Plumbing Connections MOUNTING THE CONTROL CENTER Use the flanges at the back of the control center enclosure and only mount panel in the upright vertical 9-7/8" (250.8 mm) position (door hinge is on the left). See Figure 1. 8-1/4" (209.6 mm) 1" (25.4 mm) Locate control center within sight of disposer per local codes. Locate any remote control station within sight of disposer per local codes. If box is mounted to the sink table, recess the box so 15-3/4" (400.1 m
Streszczenie treści zawartej na stronie nr. 5
Electrical Connection Diagrams 2 3 4 6 7 7 13 14 M1/M3 M2 M4/M6 M5 M7 NC NC 2 3 4 6 7 7 13 14 M1 M2 M3/M4 M5 M6 M7 NC 1 3 2 4 6 5 7 1 2 3 4 5 6 7 Motor Leads Motor Leads 24V Water Solenoid 24V Water Solenoid 1 GPM Flow Control 1 GPM Flow Control Disposer Disposer 24V Water Solenoid 24V Water Solenoid 7 GPM Flow Control 7 GPM Flow Control Pre-wired in Pre-wired in panel to panel to contactors contactors Hot L1 L2 Neutral L1 L2 Neutral Hot On On Control Center Connection Control Center Connectio
Streszczenie treści zawartej na stronie nr. 6
Electrical Connections 14 2 3 4 6 7 7 13 ELECTRIC SHOCK • Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or Jumper Wire Removed circuit tester to ensure that power is off. For Remote Operation • All installation work must conform to local 24V Water Solenoid plumbing and electrical codes. 1 GPM Flow Control Disposer • All control centers and disposers must be carefully and permanently grounded. 24V Water Solenoid 7 GPM Flow Control •
Streszczenie treści zawartej na stronie nr. 7
Operating Instructions/Aqua-Saver Adjustment NOTE: This feature is set in the manual position at the OPERATING INSTRUCTIONS factory. To activate the automatic timed disposer TO START shut-off, disconnect the electric power to the control 1. Check to ensure disposer is free of foreign objects. center, then open the control center door. Locate the 2. Ensure power is on. Dip Switch Module at the top of the printed circuit board 3. Push start button. Disposer motor will run and water (see Fig
Streszczenie treści zawartej na stronie nr. 8
Troubleshooting PERSONAL INJURY ELECTRICAL SHOCK/PROPERTY DAMAGE • Allow only trained personnel to operate disposer. • Troubleshooting other than what is recommended in this section should only be performed by • Use baffles and guarding to avoid splashing and qualified service personnel. ejection of materials. • Further troubleshooting performed by untrained • Do not put fingers or hands into the disposer. personnel could result in electric shock or damage • When attempting to remove
Streszczenie treści zawartej na stronie nr. 9
AS-101K-1 Wiring Diagram ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The disposer motor wiring connection is sh
Streszczenie treści zawartej na stronie nr. 10
AS-101K-2 Wiring Diagram ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The disposer motor wiring connection is sh
Streszczenie treści zawartej na stronie nr. 11
AS-101K-3 Wiring Diagram ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The disposer motor wiring connection is sh
Streszczenie treści zawartej na stronie nr. 12
AS-101K-4 Wiring Diagram ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The disposer motor wiring connection is sh