Streszczenie treści zawartej na stronie nr. 1
®
VENT-FREE PROPANE GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Models: VP1000BA & VP600B
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone
Streszczenie treści zawartej na stronie nr. 2
SECTION PAGE CONTENTS Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ................................................................................... 4 Unpacking...................................................................................... 4 Product Features ............................................................................
Streszczenie treści zawartej na stronie nr. 3
SAFETY WARNINGS Continued WARNING ICON G 001 INFORMATION WARNING: Any change to this heater or its controls can be dangerous. Continued 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supp
Streszczenie treści zawartej na stronie nr. 4
Ignitor Button Control Knob PRODUCT IDENTIFICATION Grill Guard Glass Panel Heater Front Cabinet Panel Figure 1 - Vent-Free Propane Gas Heater (Model VP1000BA Shown) Install and use heater with care. Follow all local codes. In the absence of local LOCAL CODES codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batter
Streszczenie treści zawartej na stronie nr. 5
FRESH AIR WARNING WARNING ICON G 001 FOR This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to COMBUSTION insure proper fresh air for this and other fuel-burning appliances in your home. AND VENTILATION Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to
Streszczenie treści zawartej na stronie nr. 6
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION FRESH AIR Determining if You Have a Confined or Unconfined Space FOR Use this worksheet to determine if you have a confined or unconfined space. COMBUSTION Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. AND 1. Determine the volume of the space (length x width x height). VENTILATION Length x Width x Height = ___________________ cu. ft. (volume of sp
Streszczenie treści zawartej na stronie nr. 7
VENTILATION AIR FRESH AIR Ventilation Air From Inside Building FOR This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the COMBUSTION ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and AND 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). VENTILATION WARNING WARNING ICON G 001 Continued Rework wor
Streszczenie treści zawartej na stronie nr. 8
VENTILATION AIR (Continued) FRESH AIR Ventilation Air From Outdoors FOR Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these COMBUSTION items directly to the outdoors or spaces open to the outdoors. These spaces include attics AND and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size o
Streszczenie treści zawartej na stronie nr. 9
INSTALLING NOTICE TO WALL A qualified service person must install heater. Follow all local codes. CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have the items listed below. • sediment trap • external regulator (supplied by • manual shutoff valve * installer, see page 13) • ground joint union • tee joint • piping (check local codes
Streszczenie treści zawartej na stronie nr. 10
For convenience and efficiency, install heater INSTALLING • where there is easy access for operation, inspection, and service • in coldest part of room TO WALL Continued CEILING 36" Minimum 6" Minimum From Sides Of Heater Right Side Left Side 3" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material FLOOR Figure 4 - Mounting Clearances As Viewed From Front of Heater INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater. WARNING WARNING ICO
Streszczenie treści zawartej na stronie nr. 11
Installing Two Mounting Screws INSTALLING Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater. TO WALL Continued Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting screw into wall stud. 3. Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall. Attaching to wall anchor method Follow instructions below to attach mounti
Streszczenie treści zawartej na stronie nr. 12
Placing Heater On Mounting Screws INSTALLING 1. Locate two keyhole slots on back panel of heater (see Figure 9). 2. Place large openings of slots over screwheads. Slide heater down until screws TO WALL are in small portion of slots. Continued Keyhole Slots Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pu
Streszczenie treści zawartej na stronie nr. 13
CONNECTING NOTICE TO GAS A qualified service person must connect heater to gas supply. Follow all local codes. SUPPLY CAUTION WARNING ICON G 001 Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of
Streszczenie treści zawartej na stronie nr. 14
IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping CONNECTING and/or fittings. TO GAS SUPPLY Continued Pressure Regulator 3/8" NPT Pipe Nipple Heater Cabinet Ground Joint Union Tee Joint Manual Shutoff Valve * Reducer Test Bushing to Gauge From External 1/8" NPT Connection * Regulator (11" W.C. to 14" W.C. 1/8" NPT Plug Tap Pressure) Tee Joint 3" Minimum Sediment Trap Pipe Nipple Cap Figure 13 - Gas Connection * An A.G.A. design-certified manual shutoff valve with
Streszczenie treści zawartej na stronie nr. 15
3. Pressurize supply piping system by either using compressed air or CHECKING opening propane supply tank valve. GAS 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. CONNECTIONS 5. Correct all leaks at once. Continued Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 14). 2. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 3.
Streszczenie treści zawartej na stronie nr. 16
OPERATING FOR YOUR SAFETY READ BEFORE LIGHTING HEATER WARNING WARNING ICON G 001 If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the
Streszczenie treści zawartej na stronie nr. 17
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including OPERATING near the floor. If you smell gas, STOP! Follow “B” in the safety information HEATER at the top of page 16. If you don’t smell gas, go to the next step. Continued C-clockwise 5. Press in control knob and turn counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 16, page 16). Note: You may be running this heater for the first time after hooking up to gas supply.
Streszczenie treści zawartej na stronie nr. 18
OPERATING TO TURN OFF GAS TO APPLIANCE HEATER Shutting Off Heater Clockwise Continued 1. Turn control knob clockwise to the PILOT position. Clockwise 2. Press in control knob and turn clockwise to the OFF position. Shutting Off Burner Only (pilot stays lit) Clockwise 1. Turn control knob clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Remove front panel (see Figure 10, page 12). 2. Follow steps 1 through 5 under Lighting Instructions, pages 16 and 17. 3. With control knob presse
Streszczenie treści zawartej na stronie nr. 19
BURNER FLAME PATTERN INSPECTING Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect BURNER burner flame pattern. The incorrect burner flame pattern shows yellow tipping of Continued the flame. It also shows the flame higher than 1/2 the glass panel height. WARNING WARNING ICON G 001 If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page. NOTICE Do n
Streszczenie treści zawartej na stronie nr. 20
CLEANING WARNING WARNING ICON G 001 AND Turn off heater and let cool before cleaning. MAINTENANCE CAUTION WARNING ICON G 001 You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc. ODS/PILOT AND BURNER ORIFICE • Use a vacuum cleaner, pressurized air, or small,