Streszczenie treści zawartej na stronie nr. 1
®
Sealtht
CONTENTS
INTRODUCTION 1
mOUNTINg RCO e mmeND a TIONs 2
PRP e aRa TION INsTRUCTIONs 3
aN f INsT LL a a TION 4
CONTROL fea TURes:
INTELI•TOUCH OPERATION 8
INTELI•TOUCH TROUBLESHOOTING 16
READ AND SAVE THESE INSTRUCTIONS
SAFETY FIRST
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product
and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this
owner’s manual completely and carefully.
Streszczenie treści zawartej na stronie nr. 2
MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mounting recommendations as you decide where to install your Casablanca fan. • For safety reasons, the fan blades must be a minimum of 7 ′ above the floor . • Do not loc
Streszczenie treści zawartej na stronie nr. 3
® Sealtht STEALTH INSTALLATION INSTRUCTIONS Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against the parts listed here. Before discarding packaging material, be certain that all parts have been removed. PERMA LOCk™ HARDw ARE • ALLEN SET SCREw DOwNROD & BALL 1 1 ⁄4-20 x ⁄4” ASSEMBLY 1/8” (PRE-INSTALLED) ALLEN wRENCH FAN PREPARATION IMpOr T aNT saFeTy INFOrMa TION! BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN, I
Streszczenie treści zawartej na stronie nr. 4
CEILING HARDw ARE ADDITIONAL HARDWARE 1 2 /4” x 8-32 ROUNDED HEAD SCREw (2) CROSSBAR wIRE NUT (4) 1” x 8-32 ROUNDED FLAT w ASHER MOUNTING HEAD SCREw (2) (2) BRACkET SUPPORT INSTALLATION PARTS LARGE LAG SCREw FLAT w ASHER 3 /8” #7 X 5” (1) 3 /8” (1) CROSSBAR MOUNTING BRACkET INSTALLATION JOIST Note: after removing the old fixture, check the outlet box to insure that it is supported by a joist or beam across its upper surface. If not, a 2” x 4” stud must be installed. Step 1. Remo
Streszczenie treści zawartej na stronie nr. 5
® Sealtht LAG SCREw INSTALLATION Step 3. With the large washer attached, pass the lag screw through the center hole of the crosbar mounting bracket and screw into guide hole. Tighten until outlet box is firmly mounted to beam. This box must be firmly secured to the ceiling. We recommend that the ceiling fixture outlet box be of sufficient capacity enabling it to support the weight of fan and light fixture under any conditions. LAG SCREw LARGE w ASHER CANOPY H
Streszczenie treści zawartej na stronie nr. 6
ATTACHING THE BLADES Step 3a. Attach the 5 blade tips to the blades using two 3a - BLADE TIP INSTALLATION: 1 6-32x ⁄8” round head screws provided. Note: the screws 1 6-32x ⁄ ” 8 have locktite on them, so once they are installed it will ROUND HEAD BLADE be difficult to remove the screws. SCREw Step 3b. a t t a c h e a c h o f t h e fi v e b l a d e s t o t h e b l a d e 1 6-32x ⁄ ” 8 holders using four of the truss head screws and fiber ROUND BLADE washers provi
Streszczenie treści zawartej na stronie nr. 7
® Sealtht CANOPY HATCH INSTALLATION Step 6. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the white and black wires are HATCH CANOPY on opposite sides of the canopy and all wires are clear CANOPY of the canopy opening. LOCk Step 7. Install canopy hatch with the last canopy screw w ASHER and lock washer. To do this, tilt the fan body away from CANOPY the hatch opening. SCREw Tip: Place the lock washer on the canopy screw, and the screw through the hatch before
Streszczenie treści zawartej na stronie nr. 8
® 3 W-85 CONTROl INSTAllATION WALL CONTROL AND HARDWARE (not to scale) (4) Wire Cap Wall Plate W-85 Switch Bezels switch Mounting Screws White Wall Almond Wall Wall Control (1) White Screws (2) (2) White Plate(1) Plate(1) (1) Almond (2) Almond WARNINg! BEZEL To avoid possible electrical shock, make cer- tain that electricity is turned off at the circuit breaker or fuse box before attempting any in- stallation or repair procedure CAUTION! NOT turning the power OFF at the circuit breaker or f
Streszczenie treści zawartej na stronie nr. 9
® 3 W-85 Wall Control Bezel replacement: - aLMOND CONTINUED BEZEL Step 17c. Reinstall the rubber key pad on to the four (4) locating pins located on the almond bezel as shown in Figure #3 and #4. RUBBER KEY PAD Figure #3 RUBBER KEY Step 17d. To attach the bezel back on to the front PAD of the switch you will need to align the four (4) tabs on the bezel with the front of the wall control and by gently pressing on both top and button of the bezel at the same time, snap the bezel back on t
Streszczenie treści zawartej na stronie nr. 10
® 3 INSTAllINg ThE W-85 W All CONTROl ® NOTE: W-85 Wall Control should only be installed on Casablanca's Inteli-Touch 3 fans with DOWNLIGHTS ONLY. The wall control installs in the same manner as an ordinary light switch, using an existing wall box and wiring. This controller is designed to signal the fan microcomputer as well as perform normal switching operations. For this reason the following precautions must be observed: 3. Do not use more than one fan per wall control. 1. Use only the Cas
Streszczenie treści zawartej na stronie nr. 11
® 3 DUAL w -85 INSTALLATION DIP SWITChES To control the fan and lights from two locations (a three-way circuit), use two W-85 wall controls as shown in the wiring diagram in Figure #5. Before installing the two switches into the wall, place both switches side by side, then locate the 4 dip switches on the side of the two switches. Then make sure that the dip switches are set to the same address on both switches as shown in Figure #4. When setting these dip switches you are setting the chan
Streszczenie treści zawartej na stronie nr. 12
® 3 OPERATION POwER The button is normally left in the on position. Always turn the power off during cleaning or servicing the fan and during thunderstorms. It is also used to exit or enter additional programs. The button must be left on to retain a previously set fan speed or light level. OPERATION SPEED CONTROL There are six individual speed settings for the fan; each speed is indicated by an audible tone of increasing pitch. FAN CONTROL To select the desired fan speed: ON - OFF: 1. With
Streszczenie treści zawartej na stronie nr. 13
® 3 CHANGING FREqUENCY SETTING DIP noTe: all fans leave the factory set to SWITChES “1111” You will only have to change the dip switch settings in the remote if you are using more than one fan in the same area and want to control them separately. Step 1. Turn power OFF at the circuit breaker or fuse box and at the toggle switch, for the fan you want to change. NOTE: DO NOT set dip switch setting in the remote to ‘0000’, this may cause frequency interference from other Casablanca Products
Streszczenie treści zawartej na stronie nr. 14
® 3 ® ® OPERATION SAFE-EXIT AND LIGHT-MINDER PROGRAM NOTE: B o t h L i g h t - M i n d e r a n d s a f e - e x i t p r o g r a m s w i l l a l w a y s r u n a t t h e s a m e t i m e . The Safe-Exit Program gives you about thirty seconds of light when you turn the lights off, enabling you to exit your home before the lights go out. To enter the Safe-Exit Program: Safe-Exit 1) T o operate the lights for safe-exit program – press the button off for at least
Streszczenie treści zawartej na stronie nr. 15
® 3 ™ OPERATION FAN-MINDER PROGRAM The Fan-Minder feature will add to your comfort when used in the bedroom. The program reduces the speed of the fan each two-hour interval to compensate for cooling night air. T o enter the Fan-Minder program: 1. Turn the OFF for at least 5 seconds. 2. Turn the ON. 3. Immediately operate the buttons in the following sequence: + + + 4. The fan will respond with three descending tones. A timer is now initiated and the fan will reduce one spe
Streszczenie treści zawartej na stronie nr. 16
® 3 TROUBLESHOOTING TIPS Please refer to this troubleshooting guide before requesting service or contacting your dealer for assistance. prOBLeM pOssIBLe reMeDIes Fan will not start • Check the main circuit fuses, circuit breakers, and wall switch position. Check all wire connections. Make sure the power is turned of f during this inspection. • pin connectors are not making good contact. Check all connections. • The fan receiver is defective. replace the fan rec
Streszczenie treści zawartej na stronie nr. 17
® Sealtht PRODUCT SPECIFICATIONS ® ® Model Name: stealth Motor: XLp-2000 Model Number: 32xxZ Blade Span: 54" Blade Iron Pitch: 14° Dimensions: A = 10.8" No. of Blades: 5 B = 13.25" ® T echnology: Inteli•T ouch 3 W-85 C = 3" NOTE: Dimension B Lightbulb: (1) 100-watt halogen includes light fixture D = 11.5" and glass. lightbulb E = 5.6" Weight: 33 lbs. airflow: 6,251 cfm Electricity Use*: 112 watts airflow efficiency*: 52.9 cfm/watt * Performance data is for fan only. No