Streszczenie treści zawartej na stronie nr. 1
®
Pool Pilot
Digital
Salt Chlorine Generator
By
Swimming Pool and Spa Purification System
Model # 75003
Owners Manual
(For Indoor or Outdoor Use)
Pool Owner - Save this manual for reference.
Installer - Leave this manual with pool owner.
IMPORTANT.
Read This Manual Before Installing & Operating
This manual covers the installation of the Digital Chlorine Generator
with any of the following Cell/Manifold assemblies (sold separately);
94105, 94107, 94113,
Streszczenie treści zawartej na stronie nr. 2
IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical The AutoPilot chlorinator is equipped with an equipment, basic safety precautions should electronic flow switch that automatically turns always be followed, including the following: the unit off in the event of a “low water flow” situation. Do not tamper in any way with this safety feature. READ AND FOLLOW A disconnect device incorporated in the fixed ALL INSTRUCTIONS wiring must be included in the supply ci
Streszczenie treści zawartej na stronie nr. 3
UNIT NUMBERS AND CONTACT INFORMATION Please record the following information prior to installation: Installer: ...................................................... Date of Installation: .................................... Control Unit Control Unit Model Type: ............................................... Serial Number: ............................................ SuperCell SuperCell Model Type: ............................................... Serial N
Streszczenie treści zawartej na stronie nr. 4
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS ..................................................................................................... ii UNIT NUMBERS / AUTOPILOT CONTACT INFO.................................................................................... iii TABLE OF CONTENTS...........................................................................................................................iv - vi SYSTEM OVERVIEW ...................................................
Streszczenie treści zawartej na stronie nr. 5
TABLE OF CONTENTS LOW VOLTAGE WIRING .................................................................................................................................... 15 CONNECTING THE SUPERCELL CABLE...........................................................................................................................................15 CONNECTING THE TRI-SENSOR CABLE ......................................................................................................................
Streszczenie treści zawartej na stronie nr. 6
TABLE OF CONTENTS SALT CALIBRATION.......................................................................................................................................... 34 ADJUSTING TEMPERATURE DISPLAY ................................................................................................................. 34 PROGRAMMING POOL VOLUME ....................................................................................................................... 34 PROGRAMMING CELL TYPE ....
Streszczenie treści zawartej na stronie nr. 7
SYSTEM OVERVIEW System Overview Although the Pool Pilot is easy to use, it is important to read through the manual before attempting to operate the unit. The Pool Pilot Digital, #75003, is a salt chlorination system for pool or spa purification, which is designed to operate in the following configurations: • Purifier – standard mode, manually adjusted purifier output. See pg. 27 for system operation and programming. • Purifier and pH Control – optional mode – standard purifier mode oper
Streszczenie treści zawartej na stronie nr. 8
SYSTEM OVERVIEW pH Control Mode (Manual purifier and pH control) Note: Requires option # 75004, 75005, 75006, or 75007 pH Acid Feed Pump and Tank System must be installed with the #75003 Digital Controller for this mode to function. Option # 75008 Auxiliary Relay Kit will be necessary if the Digital is used to control the main circulation pump. This mode adds to the Purifier mode by using an Acid feed pump that is user programmed for manual feed of diluted muriatic acid. The Acid Feed Pum
Streszczenie treści zawartej na stronie nr. 9
SYSTEM OVERVIEW Control Unit Features The control unit has the following features: • Patented temperature compensation for chlorine output CHECK SYSTEM • Programmable Microprocessor Control BOOST MENU SELECT PUMP • Multi-language digital display – (English, Spanish, French & German) • Digitally controlled power to the SuperCell • Tri-sensor Circuitry to monitor water flow, water temperature, and salt level (and salt addition amounts to maintain 3000 ppm (3.0 g/l)) •
Streszczenie treści zawartej na stronie nr. 10
SPECIFICATIONS Specifications #75003 Pool Pilot Digital Control unit Input Power 230 Vac 1.5 amps (Normal input configuration shipped from the factory) 115 Vac 3 amps (Optional input configuration – jumper wire to convert included) Dry Contact 5 mA typical Non-factory ORP input circuit (110Vac output require a Relay Kit – PN# 110-ORP) Chlorine Output SuperCell Type Maximum Chlorine Output (# 75003 Control unit set on Cell Power 3) SC-36 1.28 lbs/day (0.58 kg/day) SC-48 1.56 lbs/day (0
Streszczenie treści zawartej na stronie nr. 11
PREPARING THE POOL WATER Calculating Pool Volume (needed to determine proper balance chemical additions) (depth of deep end + depth of shallow end ) Average Depth = 2 Pool Shape Gallons (pool size measured in feet) Liters (pool size measured in meters) Rectangular Length x Width x Average Depth x 7.5 Length x Width x Average Depth x 1000 Round Diameter x Diameter x Average Depth x 5.9 Diameter x Diameter x Average Depth x 785 Oval Length x Width x Average Depth x 5.9 Length x Width x
Streszczenie treści zawartej na stronie nr. 12
PREPARING THE POOL WATER Salt Addition Chart The following salt chart is included for reference only. Once your Pool Pilot Digital is properly programmed to the pool water volume, it will automatically indicate how much salt is needed. To use this chart: 1. Find your current salt level (ppm or g/l) in the left column. (This can be obtained from your Pool Pilot display or by testing your water.) 2. Find your pool/spa volume in the second row (Gallons or Liters). 3. Find the amount of sa
Streszczenie treści zawartej na stronie nr. 13
PREPARING THE POOL WATER Basic Water Chemistry Your Pool Pilot Digital is designed to produce chlorine on a daily basis. To monitor your system’s efficiency, the water chemistry ranges and schedule of periodic checks outlined below should be followed. CHEMICAL IDEAL RANGE IDEAL TEST EFFECT OF LOW/HIGH LEVELS CORRECTIVE ACTIONS SCHEDULE Free Chlorine 1.0 To 3.0 ppm Weekly Low free chlorine: Not enough residual Low free chlorine: Check for chlorine to safely sanitize pool water. combi
Streszczenie treści zawartej na stronie nr. 14
PREPARING THE POOL WATER Saturation Index (SI) The Saturation Index is a formula used to predict the calcium carbonate saturation of water, that is, whether your water will precipitate, dissolve, or be in equilibrium with calcium carbonate. Your water is properly balanced if the SI is 0 ± 0.3. If your SI is greater than 0.3, scaling and staining will occur. If your SI is less than -0.3, then the water is corrosive to metallic fixtures and aggressive to plaster surfaces and vinyl liners.
Streszczenie treści zawartej na stronie nr. 15
INSTALLATION Before Installing the # 75003 Pool Pilot Digital System • Determine that everything needed for installation is on hand • Determine where the Manifold Assembly will be plumbed • Find a suitable mounting location for the Control Unit within proper cord length to the manifold • Plan cord runs for SuperCell Cable and Tri-Sensor Cable • For optional TC or pH control systems, plan for flow cell water feed tubes and acid feed tube and electrical connections • Plan wire runs and wir
Streszczenie treści zawartej na stronie nr. 16
INSTALLATION Plumbing Requirements The Manifold Assembly is 2” Schedule 40 and is typically plumbed into the pool return line and, if applicable, after the heater and spa return diverter valve. Electrical Requirements Power must be shut off at the circuit breaker before performing any wiring. All local and NEC electrical codes should be followed. The Pool Pilot Digital has been factory configured for 230Vac operation. If it needs to be reconfigured for 115Vac operation, then see Con
Streszczenie treści zawartej na stronie nr. 17
INSTALLATION Plumbing the Manifold Assembly Step 1: Select the location for installing the manifold: The manifold is designed for a flow rate of 20 to 100 gpm (76 to 379 L/m). • It is recommended that the manifold be installed prior to installation of the control unit. The Control Unit will need to be installed close enough to the Manifold Assembly so that the Tri-Sensor and SuperCell Cables (12’ long) will have enough slack so that the cables can be serviced easily. • The manifold/cel
Streszczenie treści zawartej na stronie nr. 18
INSTALLATION Mounting the #75003 Pool Pilot Digital Control Unit Caution: All electrical connections should be made by a licensed electrician or certified electrical contractor. Your Pool Pilot Digital is suitable for indoor or outdoor mounting. If it is connected to 230 Vac, it must be installed at least 5’ (1.5m) horizontal distance from the pool or spa wall (or more if local codes require). If it is connected to 115 Vac, it must be installed at least 10’ (3m) horizontal distance fro
Streszczenie treści zawartej na stronie nr. 19
INSTALLATION Electrical Connections The Pool Pilot Digital uses both high and low voltage connections. High voltage connections will be made for providing the direct input power to it. Additional high voltage connections may be made to the filter pump from the Pool Pilot Digital. Low voltage connections will be made to the Tri-Sensor and SuperCell. Additional low voltage connections are provided for optional equipment such as #75008 pH feeder, #75001 Pool Chemistry Controller, or an ORP
Streszczenie treści zawartej na stronie nr. 20
INSTALLATION High Voltage Wiring Connecting Power to the Pool Pilot Digital The Pool Pilot Digital is typically provided input power in one of two ways. Determine which is best for your application. • AC input directly from a circuit breaker, time clock, or pump relay in an electronic controller: This method is used when the AC power to the pump and Pool Pilot will be turned on and off by an external device such as a circuit breaker, time clock, or electronic controller. • AC input di