Streszczenie treści zawartej na stronie nr. 8
Direct Wire Power Supply Cord Fire Hazard Fire Hazard Use 10 gauge solid copper wire. Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Use a UL listed strain relief. Disconnect power before making electrical connections. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center Connect neutral wire (white or center wire) to center terminal (silver). terminal (silver). Ground wire (green or bare wire) must be connected
Streszczenie treści zawartej na stronie nr. 9
Put power supply cord through the strain relief. Be sure that the wire insulation on the • Put direct wire cable through tile strain relief. ]he strain relief should have a tight fit power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw with the dryer cabinet and be in a horizontal position. Do not further tighten strain against the direct wire cable. relief screws at this point
Streszczenie treści zawartej na stronie nr. 10
3. Connect ground wire !green or bare) of power supply cord to external ground conductor 4-wire connection: Power Supply Cord screw. Tighten screw. A B C IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do / not permit the use of 3-wire connections. B F o C D E G A. 4-wire receptacle (NFMA type 14-30R) B. 4-prong plug C. Ctound prong F E D. Neutral prong D E.Spade t_'rminals with upturned end_ £ _4" ( 1.9 cm) Ut listed strain relief A. [xternal ground conductor s
Streszczenie treści zawartej na stronie nr. 11
When connecting totheterminal block, place thehooked endofthewireunder thescrew of Connect ground wire/green or bare) of power supply cable to external ground conductor theterminal block (hook facing right), squeeze hooked endtogether andtighten screw, as screw. Tighten screw. shown, C 1, Remove center silver-colored terminal block screw. 2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wir
Streszczenie treści zawartej na stronie nr. 12
3-wire connection: Direct Wire 3-wire connection: Power Supply Cord Use where local codes permit connecting cabinet-ground conductor to neutral wire: Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed. Strip 3V2' (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2..5 cm). If A - i using 3-wire cable with ground wire, cut bare wire even with outer covering
Streszczenie treści zawartej na stronie nr. 13
B C / '_E A. Neutral ground wire B. Fxternal ground conductor screw C. C_'nte'r silver-colored terminal block screw D. Neutral wire twhite or center wire) E. _" ( 1.9 cm) U_ listed strain re'lief 3. A. Fxt_'rnal ground conductor screw Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together, lighten screws. B. Neutral ground wire C. C_'nter silve'r-colore'd terminal block scre'w D. Neutral wire (white' or
Streszczenie treści zawartej na stronie nr. 14
Rigid metal vent • For best drying performance, rigid metal vents are recommended. • Rigid metal vent is recommended to avoid crushing and kinking. Flexible metal vent • Flexible metal vents are acceptable only if accessible for cleaning. • Flexible metal vent must be fully extended and supported when the dryer is in its final location. FireHazard Remove excess flexible metal vent to avoid sagging and kinking that may result in Useaheavy metal vent. reduced airflow and poor performance. Do not u
Streszczenie treści zawartej na stronie nr. 15
Exhaust Recommended hood styles areshown here. Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B f (10.2 cm) A. louw're'd hood styli" B. Box hood style A ...................... The angled hood style (shown here) is acceptable. .............. .......... F 4" !l ; (10.2 cm)__ iiH I/_ 21/2" (6.4 cm) A. Dryer E. Clamps B. Elbow £ Rigid metal or flexible metal vent • An exhaust h
Streszczenie treści zawartej na stronie nr. 16
Alternate installations for close clearances Determine vent path Venting systems come ill many varieties. Select the type best for your installation. Two close- clearance installations are shown. Refer to the manufacturer's instructions. • Select the route that will provide the straightest and most direct path outdoors, • Plan the installation to use the fewest number of elbows and turns. • When using elbows or making turns, allow as much room as possible. • Bend vent gradually to avoid kinking.
Streszczenie treści zawartej na stronie nr. 17
3. Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in Vent system chart - 0 ft (0 m) to 10 ft (3.0 m) "Plan Vent System." Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape, _ssss/_ screws or other fastening devices that extend into the interior of the vent to secure vent. No. of 0 ft 1-.5 ft 6-10 ft Length of flexible metal vent turns or (0 m) (0.3-1.5 m) (1.8-3.0 m) elbows 0 120 ft 105 ft 90 ft (36.6 m) (32.0 m) (27.4 m) 1 110 ft 95 f
Streszczenie treści zawartej na stronie nr. 18
6_ Insert screws into bottom holes on left side of cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges. Check thelevelness ofthedryer, Check levelness firstside toside, then fronttoback. 7_ Close door and check that door strike aligns with door catch (B). If it is needed, slide door Ifthedryer isnotlevel, propupthedryer using awood block. Use awrench
Streszczenie treści zawartej na stronie nr. 19
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!iiil _i¸_iiIi!iiiiIi!iiiiIi!iiiiIi!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii(_!_i_{_ii!i_i_!_!_!_!_!_!!_ ¸ _ii_ ii}_i!i!!ii!!!i!Ji!!}i!_ii
Streszczenie treści zawartej na stronie nr. 20
}F'_ _ _ _ _ _ _ "% • _ Use the Drying Rack to dry items such as sweaters and pillows without tumbling. The drum 2. Put wet items on top of rack, leaving space between items. Do not allow items to hang turns, but the rack does not move. over the edge of the rack. Close the door. [f your model does not have a drying rack, you may be able to purchase one for your model. [b 3. Select a timed drying cycle and temperature, or an air cycle. Items containing foam, find out whether your model allows dry