Streszczenie treści zawartej na stronie nr. 1
PSERIES
P8M / P12M Series
Proofer/Holding Cabinets
(Manual Operation)
Installation and Operation Manual
234277-2
Streszczenie treści zawartej na stronie nr. 2
MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited E.Mail: vsales@moffat.com.au Main Office: (tel) (03) 9518 3888 (fax) (03 9518 3833 Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281 CANADA Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (
Streszczenie treści zawartej na stronie nr. 3
Contents List P8M / P12M Turbofan Proofer / Holding Cabinets. Model Numbers Covered in this Manual P8M - Turbofan Proofer / Holding Cabinet - 8 Tray. P12M - Turbofan Proofer / Holding Cabinet - 12 Tray. Introduction........................................................................................................... 2 Safety Information Specifications......................................................................................................... 3 Installat
Streszczenie treści zawartej na stronie nr. 4
Introduction Before using your new Proofer / Holding Cabinet, please This manual must be kept by the owner for future read this instruction manual carefully, pay particular reference. attention to any information labelled ‘WARNING’, A record of the Date of Purchase, Date of Installation ‘CAUTION’, ‘IMPORTANT’ or ‘NOTE’ in this manual. and Serial Number of the Proofer / Holding Cabinet should be recorded in the area provided below. Indicates a hazardous situation The serial number
Streszczenie treści zawartej na stronie nr. 5
Specifications P8M Proofer / Holding Cabinet P12M Proofer / Holding Cabinet P8M / P12M Specifications Tables:- Tray Details Power Ratings Tray Capacity Tray Spacing 110-120V, 1P+N+E, 60HZ, 1.45 kW 8 x US Full Pan P8M 76 mm / 3” 8 x EN 600 x 400 mm tray 220-240V, 1P+N+E, 50/60HZ, 1.50 kW 110-120V, 1P+N+E, 60HZ, 1.95 kW 12 x US Full Pan P12M 76 mm / 3” 12 x EN 600 x 400 mm tray 220-240V, 1P+N+E, 50/60HZ, 1.90 kW 3
Streszczenie treści zawartej na stronie nr. 6
Installation Installation Requirements Important: • Installation shall comply with local electrical, health and safety requirements. • It is most important that this proofer / holding cabinet is installed correctly and that the operation is correct before use. • If you have any questions regarding the proper installation and / or operation of this proofer / holding cabinet , please contact your local Turbofan distributor. Proofer / Holding Cabinet Serial Number Electrical Powe
Streszczenie treści zawartej na stronie nr. 7
Installation Water Connection 1. A cold water supply should be connected to the water inlet located on the rear right hand side of the unit. 2. A connection elbow and sealing washer are supplied with this unit for direct connection of a ¾” ID hose, and is recommended for Water easy installation and service. Connection 3. Connect to the water supply. - Max Inlet Pressure 80psi / 550kPa. 4. Turn ‘On’ the water supply to check for water leaks. NOTE: The Prover / Holding Cabi
Streszczenie treści zawartej na stronie nr. 8
Operation Operation Guide • Turbofan Proofer / Holding Cabinets have been designed to provide simple operation. • This Proofer / Holding Cabinet is intended for use in a commercial kitchen and must only be put to the use for which it was intended, i.e. proofing and holding of food products. To use this Proofer / Holding Cabinet correctly, please read the following sections carefully:- Proofer / Holding Cabinet Control Panel Description of Controls Power ‘On’ Indicator Light 1 Ind
Streszczenie treści zawartej na stronie nr. 9
Operation Operating in ‘Proof’ Mode Operating in ‘Hold’ Mode Caution Caution Take care when opening the proofer / Some parts of this proofer / holding cabinet holding cabinet door during the Proofing will become HOT during the Hold Mode and Mode. Let hot air and steam escape before could cause burns if touched accidentally. removing or replacing food as the steam produced can cause steam burns. Ensure that power to the proofer / holding cabinet is Ensure that power to the p
Streszczenie treści zawartej na stronie nr. 10
Cleaning e. Once a week, remove the side racks and water tank Cleaning Guidelines and clean any build up of product from the proofer / holding cabinet interior, using a mild anti bacterial Caution detergent and hot water solution and a soft bristled Always turn ‘Off’ the electrical power supply brush. at the mains supply before commencing f. Dry the proofer / holding cabinet thoroughly with a cleaning. soft dry cloth. This proofer / holding cabinet is not water Side Racks proof.
Streszczenie treści zawartej na stronie nr. 11
Cleaning e. Dry the racks thoroughly with a dry cloth and polish Door with a soft dry cloth. a. Wash with warm water and a mild detergent f. To refit the racks, engage the front and rear upper solution using a soft sponge in straight lines up and rack keyholes onto the upper hanger studs. down the inner and outer surfaces of the door. Rinse with clean, warm water and dry off. g. Raise the rack up again slightly until the lower rack keyholes engage onto the lower studs, ensuring that b.
Streszczenie treści zawartej na stronie nr. 12
Cleaning Lamp Glass e. Dry the lamp glass thoroughly with a dry cloth. The P8 and P12 proofer / holding cabinets are fitted with 2 halogen lamps. These are fitted on the L/H inner NOTE: The lamp glass seal must be fitted with the flat side panel, behind the L/Hand side rack. face of the seal towards the lamp glass. f. To refit the lamp glass, screw in clockwise. Do not over tighten the lamp glass. g. Refit the L/Hand side rack as shown on the prevous page. Interior Lamps a.
Streszczenie treści zawartej na stronie nr. 13
Fault Finding This section provides a reference to the more common You may encounter a problem not covered in this section, problems that may occur during the operation of your please contact your service provider who will require the proofer / holding cabinet. This fault finding guide is following information:- intended to help you correct, or at least accurately diagnose problems with your proofer / holding cabinet. • The Model and Serial Number of the proofer / holding cabinet, can
Streszczenie treści zawartej na stronie nr. 14
Electrical Schematic Electrical Schematic P8M - P12M Proofer Holding Cabinets. 12 P1 1 HEATING CIRCUIT P2 2 P3 3 HUMIDITY CIRCUIT Ø P4 4 L1 FUNCTION SWITCH WATER LEVEL SWITCH SETTINGS RELAY 8 FUSE 1 2 4 6 1 P1 1 P1 1 P1 1 10A WATER 1 3 5 P2 2 P2 2 P2 2 P 7 P HEATING TANK P3 3 P3 3 P3 3 THERMOSTAT THERMOSTAT P4 4 P4 4 P4 4 WATER OFF PROOF HOLD LEVEL FLOAT SWITCH HEATING ELEMENT WATER P8M M TANK 700W 120V ELEMENT 800W 240V 650W 120V FAN LIGHT 600W 240V WATER P12M MOTOR 2x25W SOLENOID 1200W 120V
Streszczenie treści zawartej na stronie nr. 15
Replacement Parts List Important: Only genuine authorized replacement parts should be used for the servicing and repair of this proofer / holding cabinet. The instructions supplied with the parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service provider or Turbofan Dealer. When ordering replacement parts, please quote the part number and the description as listed below. If the part required is n
Streszczenie treści zawartej na stronie nr. 16