Streszczenie treści zawartej na stronie nr. 1
f/_ Save This Manual
for Future Reference
owner's
manual
Model No.
758.144533
13 Gallon
COMFOR
WHOLE HOUSE
FOR YOUR
HUMIDIFIER
S_AFETY
13 Gallon Output
READ ALL
INSTRUCTIONS
Innovative Twin Fan
CAREFULLY
Technology
• Operating Instructions
• Parts List
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Part No. SP6167 Printed in Canada
Streszczenie treści zawartej na stronie nr. 2
FULL ONE YEAR WARRANTY ON HUMIDIFIER If within one (1) year from the date of purchase, this humidifier fails due to a defect in material or wQrkmanship, Sears will repair it, free of charge. If within two (2) years from the date of purchase, the motor fails due to defect in material or workmanship, Sears will repair it free of charge. This warranty service is available by simply returning the humidifier to the nearest Sears Service Center/Department throughout the United States. This warranty ap
Streszczenie treści zawartej na stronie nr. 3
Know Your Humidifier Operating Light Controls Bottles Fill Light Filter Support Filters Replacement Filter 42-t4911 Control Panel Cover & Pivoting Lid Removed for Clarity Description 758.144533 13 Gallon Output/24 Hrs. 2-3/8 Gallons Each Capacity of Bottles 2700 Sq. Ft. Coverage 48 Hours Run Time Variable Fan Speeds Filters 4 Yes Fill Light Water Level Indicator Yes Auto Humidistat Yes Controls Rotary Yes Operating Light Yes U.L Listed Yes AHAM Certified 120 A.C. Volts 60 Hertz 2.88 Amps Watts 1
Streszczenie treści zawartej na stronie nr. 4
Humidifier Operations Your new Sears humidifier is designed to satisfy home humidity requirements Humidified Air is Then Released through the principle of evaporation of Through the Top water into the air. After water is added to the bottles, the fil- ters begin to soak up the water and Dry Air Enters ..:_-;_ --:..". become totally saturated in approxi- Through the Rear mately 30 minutes. Air is drawn in from the rear of the humidifier, then passes through the filters by means of two circu- lati
Streszczenie treści zawartej na stronie nr. 5
Location Instructions (continued) NOTE: Due to release of cool, moist air At Least 2" From Wall from humidifier, it is best to direct air away from home thermostat and hot air regis- ters. It is best to position humidifier next to an inside wall. Hot air registers and cold air from outside walls can affect the effi- ciencies of the controls. Unit should not be placed where warm air from a hot air register blows directly on unit. Step 2 The humidifier should be positioned with the back (cord exit
Streszczenie treści zawartej na stronie nr. 6
Water Fill (continued) Notice the water bottles are designed as right and left hand units. Position them in the correct location so the humidifier can function properly. The water bottles should rest in the front of the cabinet. Each "E-Z-Fill Side-Cap" must be facing the rear of the unit. Rear of Humidifier Each water bottle is designed with an "E-Z-Fill Side-Cap" Should Always "E-Z-Fill Side-Cap" that is easily remov- Face Rear able. Remove the "E-Z-Fill Side-Cap" on the side of the water bott
Streszczenie treści zawartej na stronie nr. 7
Operating Humidifier Controls Fan Control The operating controls of your Kenmore Quiet Comfort Whole House humidifier are Your Kenmore Quiet Comfort Whole located on the top center of the humidifier. House humidifier allows a choice to be The controls are found under the smoked made for single or dual fan control. The cover, located between the air circulating slide switch allows one or two fans to be fans. Lift the control cover by placing your used. Slide the switch to the "1" position finger
Streszczenie treści zawartej na stronie nr. 8
Using Your Humidifier Step 1 Step 5 Be sure unit is full of water and plugged If humidifier stops running, the humidity in. level is at the normal requirements for that setting or it is adjusting to the home condi- Step 2 tions. The table below shows approximate Set the Fan selection switch to "2". This relative humidity percentages which cor- will allow both fans to operate if the humi- respond to the various settings of the distat senses humidity is needed. Humidity Control. Step 3 Recommended
Streszczenie treści zawartej na stronie nr. 9
Replacement and Care of Filters shock or injury from moving parts, always unplug humidifier before removing or replacing any JWARNING: To reduce the risk of parts. CAUTION: To help retard bacteria growth and keep maximum effi- ciency, the filters should be replaced at least once a season, or more often under hard water condi- tions. Use Sears recommended replacement filter. All filters may be rinsed in clear water only. Take care not to damage paper. To replace the evaporative wicking filters in
Streszczenie treści zawartej na stronie nr. 10
Replacement and Care of Filters (continued) c. Install new tilters in the tilter hous- Fixed ing track with the glue beads of the Tabs wicking pad to the inside of the filter Spring housing. Tabs d. Return the top cover of the filter housing by installing the cover over Filter the fixed tabs on the rear of the lower tilter housing and pivoting the cover down over the top of the fil- ters. Snap the cover over the two spring tabs. Rear of e. Replace the tilter housing in the cabinet. Note: There i
Streszczenie treści zawartej na stronie nr. 11
Cleaning of Humidifier CAUTION: To reduce the risk of Step 2 injury, fire or damage to humidifier, To Remove Parts use only cleaners specifically rec- ommended for humidifiers. Never a. Raise pivoting lid, remove the fan assembly which contains the motors use flammable, combustible or poi- and fans, and set aside. (See Repair sonous materials to clean your Parts list.) humidifier. To reduce the risk of b. Remove the water bottles from the cab- scalds and damage to humidifier, inet and remove the
Streszczenie treści zawartej na stronie nr. 12
Cleaning of Humidifier (continued) 2. Empty water reservoir after 20 minutes. Bi-Weekly Maintenance Rinse with water until bleach smell is Removing Scale gone. Allow unit to dry out completely. 1. Fill the water reservoir with one 8 oz. 3. Water bottles should be cleaned in cup of undiluted white vinegar. Let solu- same manner. tion stay 20 minutes. End of Season Maintenance 2. Clean all interior surfaces with soft 1, Follow bi-weekly maintenance instruc- brush. Dampen soft cloth with undiluted
Streszczenie treści zawartej na stronie nr. 13
Troubleshooting Probable Cause Trouble Remedy Unit will not run. • Humidity level is too high • Raise humidistat setting • No power • Check 120 volt power source Unit will not shut off. • Float is not free • Free float from obstruction • This is normal. A small Unit will not dry out • Water is present in the amount of water remains in completely system the cabinet. • High humidity or low • Allow unit to continue opera- tion. temperature resulting in slow evaporation I Bottles continue to • Air i
Streszczenie treści zawartej na stronie nr. 14
,lb.
Streszczenie treści zawartej na stronie nr. 15
Parts List For Sears Humidifiers Model No. 758.144533 ;0 Key t; Key No. Part No. Ddscription No, Part No. Description 1 823884 Cover Dust 21 822419-2 Cap 2 823730 Lid Stationary 22 819026 Spring Valve 3 823724-1 Lid Pivoting 23 819027 Stem Valve 4 826544-1 Knob 24 823710-2 Cabinet 5 824117-1 Cap 25 823726 Rail Kick 6 826546 Label Control 26 STD601107 * Scr, Pan Hd. Ty "AB" 10 x 3/4 7 826400 Cover Control 27 822120 Caster Twin Wheel 8 823910 Switch Slide 28 823849 Support Filter Lower 9 824691-2
Streszczenie treści zawartej na stronie nr. 16
Forthe repair or replacementpartsyouneed Call7 am - 7 pmo7 daysa week 1-800-366-PART (1-800-366-7278) Forin-homemajorbrandrepairservice (;all24 hoursa day, 7 daysa week 1-800-4-REPAIR (1-800-473-7247) Forthe locationof a SearsRepairServiceCenterin yourarea Call 24 hoursa day,7 daysa week 1-800-488-1222 Forinformationonpurchasinga Sears MaintenanceAgreementor to inquire aboutan existingAgreement Call 9 am - 5 pro,Monday-Saturday 1-800-827-6655 SEARS America's Repair Specialists The model number w