Streszczenie treści zawartej na stronie nr. 1
Nilfi sk C 105.5
Nilfi sk C 115.3
User Manual
Streszczenie treści zawartej na stronie nr. 2
Copyright © 2011 Nilfisk, Division of Nilfisk-Advance A/S
Streszczenie treści zawartej na stronie nr. 3
Nilfisk C 105.5 / C 115.3 EN Index 1 Safety precautions and warnings .............................................3 2 Description ...............................................................................5 3 Before you start using your pressure washer ...........................6 4 Operating your pressure washer ..............................................7 5 After using your pressure washer .............................................9 6 Maintenance ..............................
Streszczenie treści zawartej na stronie nr. 4
Nilfisk C 105.5 / C 115.3 safety only use original spare If the electric cable is hose between the backfl ow EN parts from the manufacturer damaged, it must be re- preventer and the high pres- or approved by the manufac- placed by the manufacturer sure washer must be at least turer. or his service agent or simi- 10 metres to absorb possible High pressure hoses, fi ttings larly qualifi ed person in order pressure peaks (min diameter and couplings are important to avoid a hazard. ½ inch).
Streszczenie treści zawartej na stronie nr. 5
Nilfisk C 105.5 / C 115.3 2 Description EN 2.1 Application This high-pressure washer has Only use the high-pressure been developed for domestic washer for purposes described use within: in this manual. - Car, motorbike, boat, cara- The safety precautions must be van, trailer, patio/drive/fl ags- observed to prevent damage tones, woodwork, brickwork, to the machine, the surface to barbecue, garden furniture, be cleaned or severe personal lawn mower injuries. 2.2 Operation elements See il
Streszczenie treści zawartej na stronie nr. 6
Nilfisk C 105.5 / C 115.3 EN 3 Before you start using your pressure washer 3.1 Mounting of trolley 1. Place the trolley handle on handle (C 115.3) the machine. 2. Secure the handle by mount- ing the 2 screws. Use the enclosed hexagon key. 3.2 Mounting of quick 1. Screw the quick coupling coupling tight on to the water inlet (2). Note: The inlet fi lter (2a) must always be fi tted in the water inlet pipe to fi lter out sand, lime stone and other impurities as these will damage the pu
Streszczenie treści zawartej na stronie nr. 7
Nilfisk C 105.5 / C 115.3 EN 4 Operating your pressure washer 4.1 Connection of high pres- 1. Mount the high pressure sure hose hose on the outlet (3). 4.2 Mounting of spray lance and Click & Clean nozzles 1. Push the spray lance (6) into the spray handle (7) and screw it on. Note: The spray lance (6) has a built-in low pres- sure nozzle that can be used for fl ushing away dirt. 2. Attach the nozzle. Warning: When attaching the Click & Clean nozzles, the pawl on the side of the
Streszczenie treści zawartej na stronie nr. 8
Nilfisk C 105.5 / C 115.3 4.3 Water connection An ordinary 1/2" garden hose of IMPORTANT! Only use wa- EN min. 10 m and max. 25 m will ter without any impurities. If be suitable. there is a risk of running sands in the inlet water (i.e. from NOTE: Connection to the public your own well), an additional mains according to regulations. fi lter (106411231) should be mounted. 1. Let the water run through the water hose before connecting it to the machine to prevent sand and dirt from penetrat
Streszczenie treści zawartej na stronie nr. 9
Nilfisk C 105.5 / C 115.3 5 After using your pressure washer EN 5.1 Storing the washer The machine should be sto- 3. Stop the machine, unplug red in a frost-free room! and wind up hose and cable. 4. Place spray handle, nozzles Pump, hose and accessories and other accessories in the should always be emptied of holders of the machine. water prior to storing as fol- lows: Should the machine by mistake be frozen, it will be necessary 1. Stop the machine (press the to check it for damage. sta
Streszczenie treści zawartej na stronie nr. 10
Nilfisk C 105.5 / C 115.3 6 Maintenance EN WARNING! Always discon- Clean the connectors of dust nect the electrical plug from the and sand. socket prior to maintenance or Rinse the detergent spraying cleaning. attachment after use. Clean the nozzles. To ensure a long and problem free working life, please take Any repair should always be the following advice: made in an authorized work- shop with original spare parts. Wash out water hose, high pressure hose, spray lance and access
Streszczenie treści zawartej na stronie nr. 11
Nilfisk C 105.5 / C 115.3 6.3 Cleaning of machine The machine should be kept EN vents clean so as to let cooling air pass freely through the ma- chine vents. 6.4 Greasing of couplings To ensure an easy connec- tion and that o-rings do not dry up, the couplings should be greased regularly. 11
Streszczenie treści zawartej na stronie nr. 12
Nilfisk C 105.5 / C 115.3 7 Trouble-shooting EN To avoid unnecessary disappointments, you should check the following before contacting the Nilfi sk service organization: Symptom Cause Recommended action Machine refuses to start Machine not plugged in Plug in machine. Defective socket Try another socket. Fuse has blown Replace fuse. Switch off other machines. Defective extension cable Try without the extension cable. Fluctuating pressure Pump sucking air Check that hoses and connections are ai
Streszczenie treści zawartej na stronie nr. 13
Nilfisk C 105.5 / C 115.3 8 Further information EN 8.1 Recycling the washer Make the old cleaner unusable As specifi ed in European Direc- immediately. tive 2002/96/EC on old electri- cal and electronic appliances, 1. Unplug the cleaner and cut used electrical goods must the electric cable. be collected separately and recycled ecologically . Do not discard electrical appli- ances with household waste. Contact your local authorities or your nearest dealer for further information. 8.2 Warrant
Streszczenie treści zawartej na stronie nr. 14
Nilfisk C 105.5 / C 115.3 9 Main Technical Data EN Type C 105.5-5 C 115.3-6 Rated pressure bar/MPa 75/7.5 80/8.0 Permissible pressure bar/MPa max. 105/10.5 max. 115/11.5 Rated flow l/min 5.2 5.2 Rated input kW 1.3 1.4 Rated voltage V 230-240 230-240 Max. water temperature °C 40 40 Inlet pressure bar/MPa 0.15-10/0.015-1.0 0.15-10/0.015-1.0 Sound pressure level dB(A) 78 78 Guaranteed sound power level dB(A) 93 93 2 Vibration according to ISO 5349 m/s < 2.5 < 2.5 10 Declaration Declaration Manufa
Streszczenie treści zawartej na stronie nr. 15
5 m 6 m
Streszczenie treści zawartej na stronie nr. 16
1 0 C 115.3 Serial no./WW/YYYY 128470090 P 8.0 MPa (80 bar) P max 11.5 MPa (115 bar) Q l/min 5.2 T in max °C 40 Weight kg 8.4 AC 230-240V/50Hz/1.4kW IP X5 Made for Nilfisk-Advance A/S P12377 O I O I 128303884
Streszczenie treści zawartej na stronie nr. 17
www.nilfi sk.com